Fix GND Airwire
Recover saved electrical and layout repairs and close low-voltage safety issues.
Verify repaired circuitry and establish a bounded motor-power implementation.
Place and route qualified additions, then run final project checks.
Waiting for input
revised-current-path-review for new calculations and subsequent physical edits. Old trial outcomes remain factual; former6mm requirement and2 A estimates below are historical, not active load limits.Table
| Item | Status | Evidence / item-level blocker |
|---|---|---|
| Inspect mirrored supply/support geometry | Completed | Inspected support positions, supply copper, output routes, load pads and prospective corridors. |
| Bank B support placement trial | Failed; restored | C18 moved (46,−29)→(51.2,−29); D20 (44,−36.5)→(51.5,−36.5), rotated 90°. Checks produced 13 copper overlaps, two via Errors, three body overlaps (D20–J39/Q17 and Q16–C18), and C18 pad-access finding. Dry-run-verified rollback restored the original state before routing. |
| Mirror that support move onto Bank A | Unattempted | The B trial was unsafe; it was not mirrored. |
| Complete 6 mm Bank A supply trunk | Unattempted | Inspected prospective upper corridor crosses preserved trigger-3 diagonal and GND stitching; lower corridor includes GND vias at approximately (−50.127,−44.373) and (−50.159,−39.068). No knowingly shorting trunk was authored. Coordinated control/via escape redesign remains necessary. |
| Complete 6 mm Bank B supply trunk | Unattempted | The enabling support placement failed and was restored; no safe complete corridor was established. |
| Local 8 A bank returns | Unattempted | Load rows are 9 mm apart with 1.5 mm-radius pads: the 6 mm geometric gap is smaller than 6 mm copper plus 0.15 mm clearance on each side (6.3 mm required). Other outer-layer alternatives cross preserved outputs/I2C/sensor copper. No complete return solution was established. |
| A OUT4 body widening | Completed, partial path only | Seven original Top segments, total 101.46282 mm, now 1 mm. Original 12.496523 mm departure remains 0.28 mm. Fresh final checks show no new violations. |
| A OUT4 departure reconstruction | Failed; restored | Attempted 0.6 mm × 0.28 mm pad escape followed by 11.896523 mm × 1 mm body. Connectivity closed but widened body shorted Q7:B. Rolled back only this delete/add trial, preserving successful seven-body widening. |
| Other seven output reroutes / parallel via arrays | Unattempted | Existing narrow custom escapes, inner-layer paths and single-via transitions require coordinated alternatives and current qualification; no speculative arrays or geometry added. |
| Mounting exclusion inspection | Completed partially | Explicit corner copper measurements below; all-layer effective-fill release remains blocked. |
| Final verification and evidence file | Completed | Fresh ALL check, routing-state and affected geometry readbacks recorded here. |
Table
| Output | Observed retained geometry | Disposition |
|---|---|---|
| A OUT1 | Top/Bottom 1 mm, Mid-Layer1 portion, two transitions | Preserved; not 2 A qualified. |
| A OUT2 | Custom Top neckdown plus Mid-Layer2 route | Preserved; neckdown/thin copper/transition qualification open. |
| A OUT3 | Mostly Top 1 mm with short 0.28 mm escape | Preserved; not thermally released. |
| A OUT4 | 101.46282 mm Top at 1 mm; 12.496523 mm Top at 0.28 mm | Partial improvement retained; Q7:B blocks attempted widened departure. |
| B OUT1 | Top/Bottom 1 mm with single transition | Preserved; single-transition qualification open. |
| B OUT2 | Custom Top plus Mid-Layer1 | Preserved; neckdown/inner-layer/transition qualification open. |
| B OUT3 | Custom Top plus Mid-Layer2 | Preserved; neckdown/inner-layer/transition qualification open. |
| B OUT4 | Short 0.28 mm Top departure plus Mid-Layer2 | Preserved; thin-copper and transition qualification open. |
Table
| Hole | Explicit nearby copper inspected | Center-to-copper-edge measurement |
|---|---|---|
| Hole1 | Widened A OUT4 diagonal | 4.36136 mm |
| Hole2 | Shown MCU_B_3V3 vertical segment | 8.275 mm |
| Hole3 | J17 GND pad | 6.000 mm |
| Hole4 | DEV_B_5V trace | 5.06160 mm |
#bc64ec4e. Failed B placement #37b1fbd2 was rolled back; no trial component placement remains. Successful seven-body widening checkpoint: #e81858eb. Failed A OUT4 departure delete/add commits #659e59c2 / #9cc54605 were dry-run-inspected and rolled back to that widening checkpoint. Final readbacks above confirm the intended retained state.pcb-placement-proposal.Superseded current requirement — 2026-10-08
Result and final verification
Assigned-item disposition
Retained route and bank-path inventory
DC estimates, not thermal/current certification
Mounting exclusion measurements and limits
Rollback audit and remaining gates