Dual ESP Carrier Fit


Updated the requirements, board markings, and documentation to 1 A per output, 4 A per bank, and 8 A total load; I also widened one output’s narrow copper connection. Fresh checks still show zero missing connections, copper shorts, or redundant traces.
The lower current reduces heating, but doesn’t clear fabrication yet: one via defect remains, and supply/return capacity plus mounting clearance still need verification. Details are in the Revised Current-Path Review; 1 A is the intended load ceiling, not an automatic hardware current limit.
What do I need to do now
Don’t order the PCB yet. You don’t need to move anything else. The next step is to have a Flux engineer help resolve the remaining via/tool blocker and review the power paths for 1 A per output, along with mounting-screw clearance.
I’ve tried several repairs, but I haven’t established fabrication readiness. A free engineering review is the most useful next step; for the protected-copper tool issue, use Flux support. After those blockers are resolved, I can verify and generate the manufacturing files.
I give you free rein to move things where they need to be to make this work.
You’ve already given me that permission, and I used it in the latest repair attempts—the blocker is not your placement restrictions. The remaining via repair and power-path verification need engineering/tool support; moving more parts without a verified solution could undo working connections, so I’m holding fabrication until those issues are resolved.
Ok
The board remains on hold for fabrication. Use the engineering-review card above or Flux support, and share the project link plus the Revised Current-Path Review so they can see the remaining blockers.

Firmware Starter
Revised load admission limits — 2026-10-08
Configure continuous load admission ≤1 A/output, ≤4 A per bank, ≤8 A aggregate load; actual switch/support current is additional source/return burden. This replaces previous2 A/channel planning. Firmware cannot guarantee measured current limits because VNQ diagnostics are disabled/not MCU-readable. Use characterized external loads and independently coordinated branch/bank protection; reject unknown inrush/inductive loads pending qualification and retain SAFE/OFF/no-auto-retry. These ceilings are planning limits, not released PCB or silicon ratings. See revised-current-path-review and bring-up-plan.
Domain separation
Build and configure each ESP32-S3 independently. MCU A owns U9 and the I2C_SDA/I2C_SCL bus; MCU B uses only MCU_B_I2C_SDA/MCU_B_I2C_SCL. Never bridge the buses in firmware or external wiring.
Safe boot sequence
  1. Set GPIO8–GPIO11 low before output initialization.
  2. Keep lighting enable GPIO21 in the disabled state until GPIO4–GPIO7 are configured.
  3. Keep CAN standby GPIO18 high; configure TWAI, then drive low for normal mode.
  4. Configure GPIO12–GPIO15 as active-low trigger inputs with debounce.
  5. Start I2C at 100 kHz; probe the local U9 sensor only on MCU A.
  6. Enter a latched SAFE state after an operator-reported/application-supervised high-side fault; do not automatically retry. VNQ diagnostics are disabled/not MCU-readable, so there is no automatic hardware-fault-status GPIO to poll.
Fault recovery on this hardware
FaultRST is only pulled HIGH through R66/R70; firmware has no connected reset output. INPUT LOW commands OFF but is not a guaranteed latch clear. Set all affected-bank GPIO8–11 LOW, request external bank OFF, isolate/correct fault and cool. Controlled bench restart is logic-first/commands-LOW, bank-last/current-limited after full applicable power removal and discharge. Power-cycle latch clearing must be verified experimentally; no guaranteed off-time is established. If still latched, stop. Dedicated FaultRST LOW-pulse reset requires separately engineered access/fixture; do not invent a firmware pin or automatically retry. See bench-assembly-evidence and bring-up-plan.
Socket and spare GPIO assignments
Both MCUs use the same physical socket mapping recorded in esp32-socket-pin-map. GPIO39 and GPIO40 are exposed on each protected spare terminal. Keep GPIO43/GPIO44 available for UART/debug where practical.
Do not assign GPIO35–37, native USB GPIO19/20, strap GPIO0/GPIO3/GPIO45/GPIO46, or onboard-RGB GPIO48. Confirm the seller pinout by socket-to-board continuity before loading vehicle firmware.
  • Revised load admission limits — 2026-10-08

  • Domain separation

  • Safe boot sequence

  • Fault recovery on this hardware

  • Socket and spare GPIO assignments