The sources disagree on contact ratings, temperature limits, and package dimensions across SRD versions. I’ll make those differences explicit and keep the guide’s verified ratings tied to the attached datasheet, rather than treating every SRD variant as interchangeable.
The Songle SRD-05VDC-SL-C is a sealed, non-latching SPDT (1 Form C) PCB relay with a nominal 5 VDC, approximately 0.36 W coil. It is commonly used to let a low-voltage controller switch an independently powered load through electrically separate contacts.
Scope and source qualification: This guide uses the older Songle SRD datasheet attached to this project for verified electrical ratings. The manufacturer's website confirms the SRD family, but a direct current manufacturer-hosted PDF was not obtained. Distributor listings and newer Songle-branded sheets differ on contact ratings, dime...
Created the cited SRD-05VDC-SL-C Application and Usage Guide in the project files, covering all seven requested sections. It explicitly flags conflicting datasheet versions, unresolved footprint dimensions, and replacement limitations—no drop-in equivalent was verified. Before production, the priority is to confirm the supplied variant’s drawing and load ratings, then qualify an active second source.
The Songle SRD-05VDC-SL-C is a sealed, non-latching SPDT (1 Form C) PCB relay with a nominal 5 VDC, approximately 0.36 W coil. It is commonly used to let a low-voltage controller switch an independently powered load through electrically separate contacts.
Scope and source qualification: This guide uses the older Songle SRD datasheet attached to this project for verified electrical ratings. The manufacturer's website confirms the SRD family, but a direct current manufacturer-hosted PDF was not obtained. Distributor listings and newer Songle-branded sheets differ on contact ratings, dimensions, temperature, release time, and allowable coil voltage; do not combine their best-case values into one specification. Confirm the supplied production variant and certification with Songle before a production or safety-critical design. Research date: October 7, 2026.
1. Quick Specifications
The relay datasheet does not provide an IC-style “Absolute Maximum Ratings” table. Maximum allowable values below are limits, not recommended operating points; nominal ratings and load-specific switching ratings are labeled separately.
Table
Parameter
Value
Classification / conditions
Coil voltage
5 VDC
Nominal operating point, coil data at 20°C.
Coil current / resistance
71.4 mA nominal; 70 Ω ±10%
At 20°C, L high-sensitivity coil.
Coil power
Approximately 0.36 W
Nominal, not a permissible total relay dissipation limit.
Pull-in voltage
75% of nominal maximum; 3.75 V derived for 5 V coil
Pickup threshold specification at 20°C; do not design the normal supply to this threshold.
Drop-out voltage
10% of nominal minimum; 0.5 V derived
Release threshold specification at 20°C; not a guaranteed hold-voltage specification.
Maximum allowable coil voltage
120% of nominal; 6 V derived
Older attached sheet, coil data at 20°C; not a recommended continuous overdrive target or all-temperature allowance.
Form C resistive contacts
7 A at 28 VDC; 10 A at 125 VAC; 7 A at 240 VAC
Attached sheet, cosφ = 1. Each rating is a voltage/current pair, not a universal 10 A rating.
Form C inductive contacts
3 A at 120 VAC; 3 A at 28 VDC
Stated conditions: cosφ = 0.4, L/R = 7 ms.
Maximum allowable contact voltage
250 VAC / 110 VDC
Separate voltage ceilings; do not assume rated current can be switched at these ceilings.
Ambient temperature
−25°C to +70°C
Attached sheet operating environment, not a storage rating.
Operate / release time
10 ms max / 5 ms max
Initial performance values; validate timing with the actual suppression circuit and contact bounce.
Coil-contact dielectric test
1500 VAC, 50/60 Hz, 1 minute
Test withstand, not a continuous working voltage or proof of reinforced insulation.
Exact mechanical drawing validation remains unresolved. Distributor lists 19.2 × 15.6 × 15.8 mm, whereas extraction of the older drawing suggested 19.2 × 15.5 × 15.3 mm. These are not an approved dimensional envelope. See LCSC C35449.
Ambiguous power entry: The older Form C table prints maximum allowable power as “800VAC/240W.” The AC unit is inconsistent with a power quantity and its relationship to the current/voltage ratings is unclear; no corrected AC switching-power limit is asserted here. Obtain a clarified, variant-specific switching envelope from Songle.
2. Pinout & Connections
Do not invent a numeric pin map. The attached manufacturer's wiring diagram has no numbered terminals and does not explicitly label its view direction. The terminal positions below describe the diagram as depicted, not an approved top-view PCB footprint. Match the library's pad numbers to physical functions before routing.
Table
Pin Number
Pin Name
Description
Best Practice
Not specified; upper-left in diagram
Coil A
One coil end
Connect to regulated +5 V in the low-side driver below.
Not specified; lower-left in diagram
Coil B
Other coil end
Connect to transistor drain; do not connect directly to an MCU GPIO.
Not specified; leftmost middle in diagram
COM
Moving/common contact
Connect the fused load supply for the example below. Not inherently GND.
Not specified; upper-right in diagram
NC
Connected to COM when de-energized
Use only if the desired unpowered state requires a closed contact; otherwise leave unconnected.
Not specified; lower-right in diagram
NO
Connected to COM when energized
Connect to the switched load for a normally-off circuit.
The five-terminal functional arrangement above follows the attached wiring diagram. With the relay disconnected from all power, identify the coil by its approximately 70 Ω resistance, then use continuity to identify COM–NC. Energize the coil through a protected 5 V test supply and confirm COM–NO continuity before accepting a footprint. Coil resistance is specified at 20°C.
3. Standard Application Circuit
5 V relay driver for 3.3 V or 5 V logic
Use a low-side logic-level N-channel MOSFET; the following is an engineering integration example, not a Songle-prescribed reference circuit:
Text
+5V_RELAY ───────── Coil A
coil
MOSFET drain ────── Coil B
MOSFET source ───── GND
MCU GPIO ── 100 Ω ─ MOSFET gate
MOSFET gate ─ 100 kΩ ─ GND
Flyback diode: cathode to Coil A, anode to Coil B
+5V_RELAY ─ 100 nF ceramic || 47 µF bulk ─ GND
Select a MOSFET with guaranteed on-resistance at the MCU's minimum gate-high voltage, not merely a low gate-threshold voltage. Check current, voltage, pulse, and thermal ratings against the coil and clamp circuit. At 20°C, the minimum coil resistance is 70 × 0.9 = 63 Ω, giving 5/63 ≈ 79.4 mA at exactly 5 V. This is a derived tolerance check, not a full cold-temperature or high-supply worst case. Reserve additional supply/driver margin.
The 100 Ω gate resistor and 100 kΩ gate-to-source pull-down are suggested starting values: the pull-down holds the relay off during reset. Connect controller GND to the coil driver's GND; the contact/load side need not share that ground.
Provide coil transient suppression. A simple flyback diode is reverse-biased while the coil is energized; its forward pulse capability must exceed the turn-off coil current, and its reverse rating must exceed the supply and expected disturbances. This polarity and suppression mechanism are described by TE Connectivity.
A plain diode slows release and can reduce contact-opening performance. For demanding load switching, evaluate a diode-plus-Zener or suitable TVS clamp; ensure the maximum drain excursion, including supply, clamp tolerance and overshoot, stays below the driver rating. Clamp energy cannot be calculated here because coil inductance is unverified. Validate the exact circuit with the actual load; see TE's coil-suppression guidance.
Place a suggested 100 nF ceramic and 47 µF bulk capacitor across the local 5 V rail and GND near the relay driver. Use a suitable voltage rating, such as 10 V or higher for a regulated 5 V rail. These are starting values, not datasheet requirements; size bulk capacitance from supply impedance, simultaneous coil count, and permitted rail droop. It does not replace a supply capable of sustained coil current.
Contact/load wiring
For a normally-off low-voltage DC load: load supply positive → appropriately rated fuse → COM; NO → load positive; load negative → load supply return. Leave NC unconnected. Coil de-energization should remove commanded power, but welded contacts remain a possible failure mode: this is not a safety-rated disconnect.
For an inductive DC load, place suitable load-side suppression across the load; the coil diode does not suppress the separately switched load. For AC loads, use a suitably rated RC snubber or MOV where required by load testing; do not put an ordinary flyback diode across AC. Choose suppression, fuse and contacts for inrush and fault behavior, not only steady-state current. A bare relay is not a relay module: it contains no assumed GPIO interface, optocoupler, LED, or external protection circuit.
4. PCB Layout & Routing Guidelines
Verify footprint orientation and drilling: The older drawing extraction suggested a 12.2 mm column separation, 12.0 mm outer-row separation, 2.0 mm offset for the middle terminal, and Ø1.3 mm holes, but these dimensions could not be validated. Treat them as unresolved, not fabrication instructions. Verify a supplier-approved drawing, finished-hole tolerances, pad numbering, and sample fit before ordering a PCB.
Keep the clamp loop small: Place the suppression device close to the coil terminals and driver. Keep coil current return separate from sensitive analog returns until a deliberate common connection; place the suggested local bypass/bulk capacitors beside the driver supply branch.
Size the entire load-current path: Use copper pours or sufficiently wide traces for COM, NO/NC and the load connector. Determine width from copper thickness, temperature rise, layer, environment and current using an appropriate IPC-2152 method; there is no defensible universal “10 A trace width.” Check pad neck-downs, connector ratings and via capacity as well.
Engineer thermal reliefs: Through-hole contact pads may need thermal relief for solderability, but relief spokes must carry the full load current. Do not accept default thin spokes on high-current contacts; coordinate soldering process and copper connectivity with the fabricator.
Preserve insulation spacing: Keep hazardous contact copper and load connectors separated from coil/control copper on every layer, including under the relay. Set creepage/clearance from the applicable product standard, working voltage, pollution degree, material group, altitude and insulation class; add slots only when correctly designed. The relay's dielectric test is not a PCB spacing rule. Differential-pair routing is not applicable to this relay.
5. Common Pitfalls / Things to Watch Out For
Driving the coil from GPIO or omitting/reversing suppression. The nominal coil current is 71.4 mA, not a logic-input current. Use a driver and a defined off-state; a reversed flyback diode creates a supply short when the driver turns on. Do not assume the published release time still holds with a simple diode clamp.
Treating the relay as universally “10 A,” or mirroring the footprint. Load type and voltage matter; the attached Form C sheet gives lower ratings for some resistive and inductive loads. Check NO versus NC, inrush, expected life, suppression and isolation requirements. Verify continuity and physical fit rather than assigning numeric pins from a generic internet illustration.
6. Popular Alternatives & Equivalents
No drop-in replacement is verified by this research. Functional similarity does not establish pin compatibility, drilling compatibility, enclosure clearance, certification equivalence or load-life equivalence.
Manufacturer ordering table confirms a standard PCB-terminal SPDT relay with 5 VDC coil. Standard resistive ratings include 10 A at 120 VAC and 8 A at 30 VDC.
Functionally similar only. Pin/footprint compatibility not established. Check its enclosure/cleaning requirements and coil drive independently. Available in Flux.
Manufacturer product page confirms sealed 1 Form C, 5 VDC, 72 mA, 360 mW; lists 5 A at 30 VDC and 10 A at 125 VAC among resistive ratings. Manufacturer labels this part discontinued; library also marks it obsolete.
Functionally similar only; legacy-service option, not a recommended new-design shortage strategy. Pin/footprint compatibility not verified. Available in Flux.
Candidate from the manufacturer HF3FF family and published ordering scheme. Exact-variant datasheet evidence remains unverified: extraction/indexing was still pending after two attempts. Do not assume identical NO/NC ratings or qualify it from family headline ratings.
Candidate functional alternative only; not verified as drop-in, pin-compatible or footprint-compatible. Exact MPN library search did not find a match.
For a shortage, prioritize qualifying an actively sourced part against the actual load and safety requirements; do not substitute a discontinued relay solely because a broker lists stock. Two verified functional alternatives are included above, but one is obsolete and the third candidate remains unresolved; an active, fully verified second-source BOM is not established by this guide.
7. Sourcing & Purchasing Guide
Table
Attribute
Details
Primary Distributors
Exact Songle MPN found at LCSC C35449. JLCPCB C35449 lists an assembly-supply option, not a standalone parts shipment. Manufacturer authorization for these Songle channels was not independently confirmed. Exact Songle stock at DigiKey, Mouser and Arrow was not verified; use manufacturer-confirmed franchised channels when qualifying alternatives.
Packaging Options
LCSC sells by piece. Exact manufacturer bag/carton quantity and tape-and-reel availability were not verified. The listing's “Through Hole,19.2x15.6mm” is package geometry, not shipping packaging. JLCPCB's generic “Full Reel” field must not be interpreted as proof this through-hole relay ships on tape-and-reel.
Standard MOQ
LCSC indexed listings show minimum 1 and multiple 1; JLCPCB lists minimum 1 for assembly supply. Confirm current MOQ at checkout. A universal factory MOQ is unverified.
Sourcing Advice
Order the complete SRD-05VDC-SL-C code: 05VDC selects coil voltage, S sealed structure, L approximately 0.36 W coil, C 1 Form C. Obtain the current supplier/manufacturer drawing, contact-material/compliance declaration and variant-specific approvals. The attached older sheet lists AgCdO contact material; a blanket RoHS claim is not established for every revision. Avoid untraceable marketplace stock and relabeled parts; retain lot and date-code records. Price, stock and packaging can change.
Sources
Songle SRD manufacturer-authored datasheet attached to this project: two-page legacy document, sections 3–8; revision/date not stated. Public matching legacy copy: SRD-Series_Songle-Relay.pdf. This is a third-party-hosted manufacturer document, not a verified current manufacturer-hosted issue.
Songle official site:Ningbo Songle Relay, SRD product family and manufacturer identity. Direct current datasheet URL not obtained.
Omron primary datasheet:G5LE PDF; manufacturer G5LE product page lists a datasheet update of April 1, 2026; that webpage date is not asserted as the revision date of the queried PDF.
Distributor/assembly purchasing sources:LCSC C35449, JLCPCB C35449. Used for purchasing information and disclosed discrepancies, not to override attached-datasheet ratings.