Magnetic IGCSE Circuit Blocks


Created a project doc

Circuit Block Design Brief

View Document

Circuit Block Design Brief User requirements
  • Modular blocks measuring 30 × 30 × 30 mm.
  • Blocks attach to each other using neodymium magnets.
  • Each block represents a component in the IGCSE physics curriculum.
  • Joined blocks must form real, working electrical circuits.
Current state
The project has no components or nets. No mechanical design, circuit design, part sourcing, simulation, or verification has been performed. This brief records the initial request for continuation.
Proposed starting direction — not yet approved or verified
  • Use a low-voltage, current-limited DC power block; no mains connection.
  • Separate magnetic retention from electrical conduction, using captive magnets and dedicated electrical contacts. Contact geometry and polarity arrangements still n...
The key design challenge is making the 30 × 30 × 30 mm blocks connect reliably and safely, not just stick together.
My recommended starting architecture is:
  • Captive neodymium magnets for attachment, with separate electrical contacts for reliable conduction.
  • A low-voltage, current-limited power block that tolerates accidental short circuits.
  • Clearly marked circuit symbols and terminals on each block.
  • An initial set covering power, connecting links, switches, resistors, lamps, LEDs, and junctions, followed by curriculum-specific additions.
Magnets must be permanently enclosed: loose neodymium magnets pose a serious ingestion hazard.
I saved your requirements and these preliminary recommendations in Circuit Block Design Brief. No circuits or mechanical models have been built or verified yet. Detailed design, part research, and testing will need Agent mode.
Two decisions are needed first: which IGCSE exam board/syllabus are you targeting, and should circuits lie flat on a desk or connect in three dimensions?
Execution stopped because your ACUs ran out.
What is Agent mode?
Agent mode lets Flux build, do deep research, validate designs, and work through complex assignments.
Chat mode is just as smart and has the same engineering knowledge, but it cannot work autonomously.
Only Agent mode consumes your plan's included AI usage (measured in ACUs).
Continue in Agent Mode
No schematic yet

Talk to Flux to get started.

Circuit Block Design Brief
User requirements
  • Modular blocks measuring 30 × 30 × 30 mm.
  • Blocks attach to each other using neodymium magnets.
  • Each block represents a component in the IGCSE physics curriculum.
  • Joined blocks must form real, working electrical circuits.
Current state
The project has no components or nets. No mechanical design, circuit design, part sourcing, simulation, or verification has been performed. This brief records the initial request for continuation.
Proposed starting direction — not yet approved or verified
  • Use a low-voltage, current-limited DC power block; no mains connection.
  • Separate magnetic retention from electrical conduction, using captive magnets and dedicated electrical contacts. Contact geometry and polarity arrangements still need design and verification.
  • Permanently enclose magnets to reduce detachment and ingestion risk.
  • Label blocks with circuit symbols, terminal identification, and polarity where relevant.
  • Account for short circuits, reverse connections, contact heating, and exposed terminal bridging as normal foreseeable classroom use.
Decisions needed before detailed design
  1. Which exam board and syllabus version should the component set cover?
  2. Are blocks connected flat on a desk, in three dimensions, or both? How are junctions and crossing paths represented?
  3. What learner age and supervision level are intended?
  4. Which initial components are essential? A possible starter set is power, connecting link, switch, resistor, lamp, LED, and junction; this is a proposal, not an agreed curriculum mapping.
  5. Preferred power source, budget, manufacturing method, and expected quantity.
Next engineering work
Define the initial teaching circuits and terminal convention; select a safe power architecture; develop and test a magnetic/contact interface within the 30 mm envelope; then design representative blocks and validate mechanical fit, electrical continuity, misuse protection, and classroom usability.
  • User requirements

  • Current state

  • Proposed starting direction — not yet approved or verified

  • Decisions needed before detailed design

  • Next engineering work