3D Salt Funnel Simulation


Thought for 2 mins 11 sec
Thought for 5 sec
2/2 Check the simulation outputs and deliver the animation with its assumptions and limits.
Accessed knowledge for the next task.
Thought for 9 sec
Awaiting 1 task
Thought for 6 sec
2/2 tasks completed.

Inspect the existing simulation and create a watchable 3D granular-flow simulation using the funnel model.

Check the simulation outputs and deliver the animation with its assumptions and limits.

"3D Salt Flow Verification" completed.
The 3D salt-flow simulation is ready. It uses your actual funnel geometry; grain sizes and friction are illustrative estimates from the earlier study, not measured salt properties.
Watch it
  • Open interactive 3D playback — rotate, zoom, pause, scrub, and use the cutaway to see inside.
  • — 3 seconds of simulated flow shown over 12 seconds.

3D salt-flow simulation preview

The simulation includes gravity, grain–wall collisions, and grain–grain collisions. All 450 modeled grains, with diameters of 5–7 mm, exited through the spout in this run.
I also updated Salt Flow Simulation with playback and assumptions. Your funnel geometry is unchanged.
Limit: this is an approximate particle simulation, not proof that real, irregular or damp salt will flow without clogging.

No schematic yet

Talk to Flux to get started.

Design and Print Record
Current revision: 110 mm overall height
Completed: shortened only the upper funnel by 53 mm, from 163 mm to 110 mm overall. No uniform scaling, mouth cropping, support geometry or spout change. The validated build123d construction was retained with only the height parameter and explanatory comments changed.

3D Model

Design view of Design and Print Record
Warning: the shorter chute is shallower and its outside exceeds the uncalibrated 45° overhang reference. This revision is not qualified as support-free. Actual fit, salt flow, slicing and print performance are untested.
Sources and assumptions
  • User: latest request is 110 mm total height, shortening mostly the upper part. Retain 140 mm mouth OD, 55 mm offset and insertion spout.
  • User: 25 mm spout OD is already derated from a measured 27-something mm opening. Additional fit derating remains zero. Bore remains 21.8 mm.
  • User: approximately 35 mm from actual opening edge to wall, not opening center to wall. PLA and Bambu Lab A1 mini.
  • Manufacturer: A1 mini specifications gives 180 × 180 × 180 mm build volume and included 0.4 mm nozzle. Installed nozzle remains unknown; 0.4 mm provisional.
  • Layer height 0.2 mm, brim and support advice are provisional engineering recommendations, not sliced settings.
  • Mass uses assumed generic PLA density 1.24 g/cm³, not filament-specific certification.
Measured geometry
Measured from the newly pipeline-generated STEP, independently imported. Rounded beyond kernel tolerance.

Table


FeatureCurrent measured result
Bounds140 × 140 × 110 mm
Source boundsX/Y −70 to +70 mm; Z 0–110 mm
Mouth / spout center offset55 mm, spout at (−55, 0) mm
Spout OD / minimum bore25.000 / 21.800 mm
Insertion length18 mm, including unchanged bottom lead-in
Outer straight tubeZ 0.3–18 mm
Inner cylindrical boreZ 0–20 mm
Mouth outside / clear diameter140.000 / 135.900 mm
Outer / inner chute rise92 / 90 mm
Regular tube wall1.600 mm
Exact minimum chute opposing-face distance1.29775 mm
Sampled chute wall-distance range1.29788–2.56098 mm
Bottom chamfer / tip land0.3 mm at 45° / 1.3 mm
Annular bed-contact area94.342 mm²
Volume56,630.430 mm³ = 56.630 cm³
Estimated solid PLA mass70.22 g, excluding brim/support and process variation
Center of mass(−20.1369, −0.0001, 70.5953) mm
The 2.05 mm radial wall at the mouth was retained; shortening reduces its normal thickness. The chute minimum is now about 1.30 mm, versus 1.62 mm previously. It remains above the 1.2 mm process minimum but is thinner than the earlier nominal 1.6 mm nonstructural wall target. No unrequested wall, diameter or offset change was made. Minimum distance is an exact face-to-face measurement; maximum is sampled, not globally optimized. Sampling used 1,305 points on exact chute surfaces.
Spout unchanged: direct comparison
Clipped both old and new pipeline STEP solids to Z = 0–18 mm. Each clipped spout volume is 2,113.676104 mm³. Their exact Boolean symmetric-difference volume is 0 mm³. This verifies the complete insertion spout, bore and bed lead-in are unchanged, not merely that their labels match.
Slopes and flow consequences

Table


CheckCurrentPrevious tall version
Minimum inner chute slope above horizontal, sampled exact normals38.7719°51.9189°
Minimum outer chute slope above horizontal39.2755°52.1935°
Maximum outer chute overhang from vertical50.7245°37.8065°
Minimum inner STL triangle slope above horizontal38.07°50.06°
Maximum outside STL chute overhang from vertical51.93°39.23°
The far-side exterior now exceeds the 45° from build-vertical reference. The reduction also makes salt flow less favorable than the tall version; geometric slope does not establish flow reliability. Large/damp grains can bridge. The inlet and outlet remain continuous and open, without shelves, crossbars, internal supports or enclosed cavities. Tube-to-chute transition is continuous but not tangent-filleted.
Exact sections at Z = 0, 0.3, 10, 18, 20, 50, 100 and 109.999 mm each show two closed loops. The bore remains 21.8 mm through Z = 20 mm and then opens monotonically.
Wall clearance
Unchanged XY geometry: wall-side mouth reach 15 mm from spout center, only 2.5 mm beyond spout edge; opposite-side reach 125 mm. Using 27.0 mm as conservative lower bound of the reported opening and the approximate 35 mm edge gap, estimated wall clearance remains 33.5 mm, with the compact side toward the wall and the spout centered. This is a calculation from approximate user measurements, not verified installed clearance.
Provisional print recommendations
  • PLA; A1 mini; 0.4 mm nozzle PROVISIONAL; 0.2 mm layers PROVISIONAL.
  • Outlet-down, annular tip at Z = 0; source/model rotation zero. Wall-facing compact side toward −X.
  • 10 mm external-only removable brim for the small annular foot; no internal brim and no bore support. Brim is not fused to CAD.
  • Without supports, conservative model-plus-brim envelope 147.5 × 140 × 110 mm, within the manufacturer build volume. Actual purge/exclusion zones and any external support footprint must be checked in the slicer.
  • Inspect the far-side exterior overhang in the slicer. Use accessible, build-plate-only external support beneath that chute if needed; keep all support outside the bore and salt-contact path. Removal is from the open exterior. No support geometry was added to the CAD, and no automatic support result was validated.
  • Adaptive-width perimeter coverage is appropriate; approximately four lines at the 1.6 mm tube does not mean every sloped section has the same normal thickness. Inspect thinner approximately 1.30 mm upper wall and thicker neck coverage. Do not use vase mode.
  • The center-of-mass projection remains about 34.9 mm from the spout center, outside the small foot and nominal brim radius. The part relies on bed adhesion during printing and is not freestanding after release. Good first-layer adhesion and reduced acceleration remain advisable.
  • Slicing NOT VERIFIED: Bambu Studio, OrcaSlicer and PrusaSlicer were unavailable in the inspection environment. No G-code, print duration, support placement or tuned 3MF printer profile was produced. Pipeline 3MF is a geometry format.
Verification ledger

Table


ItemResult
Parameter revision/uploadPassed first upload, no geometry repairs
Independent STEP inspectionValid, one solid, seven faces
Dimensions and retained offset/spoutPassed, including zero lower-spout Boolean difference
New STL16,612 triangles, watertight, consistent winding, one body, Euler 0
STL bounds140 × 139.9565 × 110 mm; Y difference is circular tessellation
Minimum wall check1.29775 mm chute minimum, explicitly thinner than prior version
Overhang criterionWarning: exceeds 45° reference, support-free printing not established
Root placementSalt funnel v2, active, scale 1, zero pose, Z-up
Native rendersNew iso, side and top views generated and visually inspected
User live browser screenNot directly observed; native project scene rendered successfully
Physical fit, salt flow, strength, print adhesion and motion stabilityNOT VERIFIED
Slicer extrusion/support checksNOT VERIFIED
Asset and scene IDs
  • Asset offset-funnel-110.build123d, UID 34350a82-6dea-4b53-a2e3-599e6da47a27.
  • Durable current CAD:

    3D Model

  • Salt funnel v2, node UID 554e279d-c8d6-48de-b6dc-f0b55513fec0, parent ROOT.
  • Asset pipeline offers source, STL, STEP, BREP, OBJ, 3MF and GLB. New STEP and STL downloaded and inspected; new 3MF availability listed, not independently inspected this revision.
  • Version replacement removed the earlier scene node and unused model asset. Project history can restore them. No board or electronics exists.
Concept and history

Original pre-CAD concept, taller proportions

Historical concept is illustrative and depicts the earlier taller proportions, not the current 110 mm height. No new sketch was needed for this dimensional revision.
The initial Fabricator build and two focused repairs failed. A separately user-authorized alternate-kernel repair produced the valid 163 mm version. The current 110 mm version is a new user-requested dimensional revision, made with one straightforward parameter change and no new geometry repair loop.
  • Current revision: 110 mm overall height

  • Sources and assumptions

  • Measured geometry

  • Spout unchanged: direct comparison

  • Slopes and flow consequences

  • Wall clearance

  • Provisional print recommendations

  • Verification ledger

  • Asset and scene IDs

  • Concept and history