| Component/Subsystem | Failure Mode | Effect on System | Severity (1-10) | Likelihood (1-10) | Detection (1-10) | RPN | Mitigation |
|---|---|---|---|---|---|---|---|
| Future LiPo power path | Short/reverse battery/no coordinated fuse | Fire/burns and board destruction | 10 | 5 | 7 | 350 | Do not connect battery; source pack/fault data and design protection |
| Future per-cell monitor | Weak cell/open balance tap | Overdischarge, damage or lost power | 9 | 5 | 8 | 360 | Protected filtered taps/open-wire diagnostics; early motor shedding, critical cutoff |
| Motor cutoff | Stuck-on switch/lost watchdog | Uncontrolled torque | 10 | 4 | 8 | 320 | Independent normally-off high-side disconnect, fault latch, deliberate rearm and mechanical support |
| Motor regeneration | Disconnect opens without retained absorber | Rail overvoltage/damage/backfeed | 9 | 5 | 8 | 360 | Motor-side energy absorption/reverse isolation sized from measured energy |
| Robot mechanics | Torque removal | Collapse/pinch injury | 9 | 6 | 6 | 324 | Physical restraint and exclusion zone; torque-off alone not safe posture |
| Jetson branch | Motor sag before shutdown | Abrupt reset/data loss | 7 | 6 | 6 | 252 | Loaded-voltage budget, early warning, shutdown reserve; evaluate regulated/hold-up alternative if needed |
| Logic domains | Off-side floating/injection | Spurious clocks/commands or phantom powering | 7 | 5 | 7 | 245 | Destination isolation plus defined idle bias; test all rail permutations |
| Head harness | Wrong custom PH4 connection | 5V on3V3 GPIO/damage | 8 | 5 | 7 | 280 | Not Qwiic labels, keyed views and continuity; keep incomplete face disabled |
| Audio BTL | Output tied to ground/AUX | Amplifier/bench damage | 7 | 4 | 6 | 168 | Passive rated load, differential probe, two floating speaker leads |
| Thermal/power connectors | Unbudgeted aggregate current | Overheat/melt | 9 | 5 | 7 | 315 | Complete load/contact/wire/ground-return budget before power-on |
| Communications/firmware | Stale/corrupt commands | Loss of control | 9 | 5 | 7 | 315 | CRC/sequence/bounded queues, timeout, independent hardware watchdog |
| RF/EMI | Noise/antenna integration error | Sensor/audio faults or noncompliance | 6 | 5 | 7 | 210 | Radio initially disabled by firmware proposal; certify actual integration and test EMC |
Motor power hazard gate — 2026-10-22
Scope
Failure Mode Table
U2D2 migration hazards — open,not validated
Hazard Categories to Evaluate
Risk Priority Actions