Datasheet Review


I’ll inspect the part metadata and existing symbol/footprint, find the official datasheet if needed, update the Datasheet property, then compare pins and footprint details against the datasheet.
I found and set the official TRACO datasheet URL, and I’m documenting the datasheet comparison plus the footprint issue now.
Created a project doc

Part Datasheet Review - THN 15-2411WIR

View Document

Date: 2026-07-12 Reviewed available part/project information, searched for and set the official datasheet URL, then cross-checked schematic ...
Completed the review and set the part’s Datasheet URL to the official TRACO Power THN 15WIR PDF. Full findings are in Part Datasheet Review - THN 15-2411WIR.
Open items:
  • Critical mismatch: footprint pads are all stacked at (0,0) with near-zero size, so the footprint is not usable as-is.
  • Pin numbers/functions match the datasheet, but pin descriptions and electrical pin types are not populated.
  • Library index shows Other for part type/manufacturer despite correct project properties.
Suggested next steps:
  1. Rebuild the footprint from the datasheet 6-pin 1" × 1" through-hole module coordinates.
  2. Add proper pin descriptions and electrical pin types.
  3. Add package outline/courtyard and practical plated-through pad/drill sizing for 1.0 mm pins.
Fix footprint and metadata
Rebuild footprint
Add pin metadata
Run validation
Update review document

Part Datasheet Review - THN 15-2411WIR
Date: 2026-07-12
Scope
Reviewed available part/project information, searched for and set the official datasheet URL, then cross-checked schematic pin terminals, footprint pads, and pin descriptions against the TRACO Power THN 15WIR datasheet.
Current Flux Part Information

Table


FieldCurrent value
Project/partTHN 15-2411WIR
Part UIDb7880b87-294c-4195-bc57-85db7072fd1e
DescriptionIsolated Module DC DC Converter 1 Output 5V 3A 9V - 36V Input
Manufacturer Part NumberTHN 15-2411WIR
Manufacturer NameTraco Power
Designator PrefixU
Part Type propertyPower Supplies
Library indexed part_type/manufacturerOther / Other
Package/caseModule
Terminal count6
Lifecycle statusActive
Datasheet URLhttps://www.tracopower.com/products/thn15wir.pdf
Available distributors shown by libraryTME, Mouser, Arrow, Verical, LCSC
Note: the Flux library search index still reports part_type: Other and manufacturer: Other, even though the part-level properties correctly contain Part Type: Power Supplies and Manufacturer Name: Traco Power.
Datasheet Source
Official datasheet URL set on the part:
The official TRACO PDF URL was found via web search/distributor datasheet links. The automated PDF scrape of the official URL returned a fetch error/403 in one path, but the datasheet content was successfully extracted through Flux datasheet search using the project datasheet property and corroborated by a Mouser-hosted copy of the TRACO datasheet.
Key Datasheet Specs

Table


ItemDatasheet value
SeriesTRACO Power THN 15WIR Series
Specific reviewed order codeTHN 15-2411WIR
FunctionRailway-grade isolated DC/DC converter
Output power15 W
Input9-36 VDC, 24 V nominal
Output5 VDC, 3 A
Typical efficiency90% for THN 15-2411WIR
Isolation3000 VDC input-to-output, 60 s
Package1.0 in x 1.0 in x 0.39 in metal case module
Metric package size25.4 mm x 25.4 mm x 9.9 mm
MountingThrough-hole PCB module
Pin count6
Pin diameter1.0 mm typ.
Operating temperature-40 C to +90 C; up to +93 C with heatsink per datasheet conditions
Case temperature max+105 C
Protections/featuresUVLO, short-circuit protection with auto recovery, internal pi filter, remote on/off, trim
Recommended input fuse for 24 V input models3150 mA slow-blow
Remote on/offPassive/open = on; 3.0-15 V or open = on; 0-1.2 V or short = off; referenced to -Vin
TrimSingle-output models only; external trim resistor; +/-10% for this 5 V model
Datasheet Pinout vs Flux Symbol Terminals
Datasheet single-output pin table:

Table


PinDatasheet functionFlux terminal/designatorFlux pin typeMatch?Notes
1+Vin / Vcc+VINVCCUnspecifiedPass, naming normalizedFunction and number match. Name omits slash/spacing but is recognizable.
2-Vin / GND-VINGNDUnspecifiedPass, naming normalizedFunction and number match. Name omits slash/spacing but is recognizable.
3+Vout+VOUTUnspecifiedPassFunction and number match.
4TrimTRIMUnspecifiedPassFunction and number match.
5-Vout-VOUTUnspecifiedPassFunction and number match.
6Remote On/OffREMOTE_ON/OFFUnspecifiedPassFunction and number match.
Symbol / Pin Description Findings
  • Pin count is correct: 6 schematic terminals.
  • Pin numbers match the datasheet single-output pinout.
  • Pin names/designators match semantically.
  • Pin descriptions are not populated; the terminal components only expose pin number and unspecified pin type.
  • Pin electrical types are all Unspecified; more useful types would be Power In for pins 1/2 input, Power Out for pins 3/5 output, and Input or Signal for Trim and Remote On/Off.
  • No schematic nets are present, which is acceptable for a standalone part definition but means there is no application wiring to validate.
Datasheet Mechanical / Footprint Reference
Datasheet mechanical view is bottom view. Using pin 1 as (0, 0), with X positive to the right and Y positive downward in the datasheet bottom view:

Table


PinX mmY mmFunction
10.000.00+Vin / Vcc
2+5.080.00-Vin / GND
6-7.620.00Remote On/Off
5-7.62+20.32-Vout
4+2.54+20.32Trim
3+12.70+20.32+Vout
Equivalent package-edge bottom-view coordinates using the package top-left corner as (0, 0):

Table


PinX mmY mmFunction
62.542.54Remote On/Off
110.162.54+Vin / Vcc
215.242.54-Vin / GND
52.5422.86-Vout
412.7022.86Trim
322.8622.86+Vout
Datasheet-extracted mechanical notes:
  • General tolerance: +/-0.5 mm.
  • Pin pitch tolerance: +/-0.25 mm.
  • Pin diameter: 1.0 mm.
  • Explicit pad diameter or plated-through drill recommendation was not found in the extracted datasheet text.
Footprint Cross-check
Current Flux footprint/pad data inspected:

Table


PadCurrent computed positionCurrent computed sizeCurrent shapeMatch?
+VINVCC(0, 0)0.0016 mm x 0.0016 mmcircularFail
-VINGND(0, 0)0.0016 mm x 0.0016 mmcircularFail
+VOUT(0, 0)0.0016 mm x 0.0016 mmcircularFail
TRIM(0, 0)0.0016 mm x 0.0016 mmcircularFail
-VOUT(0, 0)0.0016 mm x 0.0016 mmcircularFail
REMOTE_ON/OFF(0, 0)0.0016 mm x 0.0016 mmcircularFail
Footprint Findings
  • The footprint is not valid for manufacturing or layout use in its current state.
  • All six pads are stacked at the origin instead of the datasheet bottom-view pin coordinates.
  • Pad size is effectively zero (0.0016 mm), not suitable for a 1.0 mm through-hole pin.
  • No explicit pad/drill rules are present.
  • The package outline/courtyard for the 25.4 mm x 25.4 mm module is not represented in the inspected layout nodes.
Mismatches / Issues to Flag
  1. Critical footprint mismatch: all pads are stacked at (0,0) and are near-zero size. This must be fixed before the part can be used on a PCB.
  2. Missing/weak pin metadata: pin numbers and functions match, but pin descriptions and electrical pin types are not set.
  3. Library indexing inconsistency: library search reports part_type: Other and manufacturer: Other, although project properties have Part Type: Power Supplies and Manufacturer Name: Traco Power.
  4. Datasheet exact pad/drill dimensions were not found in extracted text. Use the 1.0 mm pin diameter and standard through-hole manufacturability rules to choose a suitable plated drill/pad, or obtain the manufacturer recommended land pattern if available.
  • Rebuild the footprint with six through-hole pads at the datasheet coordinates.
  • Add a 25.4 mm x 25.4 mm component outline/courtyard and maintain bottom-view/top-view orientation carefully.
  • Choose a practical plated-through drill larger than the 1.0 mm pin diameter, with an annular pad sized for the target fabricator, unless an official recommended drill/pad is obtained.
  • Populate pin descriptions and electrical pin types:
    • Pin 1 +Vin/Vcc: Power In
    • Pin 2 -Vin/GND: Power In or Ground/Power return, depending Flux convention
    • Pin 3 +Vout: Power Out
    • Pin 4 Trim: Input/Signal
    • Pin 5 -Vout: Power Out return
    • Pin 6 Remote On/Off: Input/Signal
  • Consider updating library index fields so manufacturer and part type appear as Traco Power and Power Supply rather than Other.
Internal Escalation
A part quality report was filed because the footprint appears unusable as-is.
  • Scope

  • Current Flux Part Information

  • Datasheet Source

  • Key Datasheet Specs

  • Datasheet Pinout vs Flux Symbol Terminals

  • Symbol / Pin Description Findings

  • Datasheet Mechanical / Footprint Reference

  • Footprint Cross-check

  • Footprint Findings

  • Mismatches / Issues to Flag

  • Recommended Remediation

  • Internal Escalation