SSW-112 Footprint Audit


I’ll check the footprint dimensions and Samtec drawing, correct the scale and plated holes, then verify all 12 pads.
Thought for 12 mins 44 sec
Thought for 8 sec
Created 2 tasks.
1/2 Correct footprint scale and define Samtec plated through-holes.

Correct footprint scale and define Samtec plated through-holes.

Verify pad geometry and report the source part defect.

Thought for 16 sec
Awaiting 1 task
"SSW-112 Footprint Audit" completed.
Thought for 2 mins 31 sec
Thought for 6 sec
Managing 1 task
Thought for 9 sec
2/2 Verify pad geometry and report the source part defect.

Correct footprint scale and define Samtec plated through-holes.

Verify pad geometry and report the source part defect.

Thought for 7 sec
Referenced guidance.
Thought for 10 sec
Awaiting 1 task
"Footprint Verification" completed.
Fixed all 12 pads to use centered Ø1.04 mm plated through-holes, and verified 1.95 mm copper, 2.54 mm pitch, and 27.94 mm span. The footprint was already correctly scaled—the flagged values were in meters, not millimeters.
Details are in the footprint audit; drill exports remain unverified, and I filed an internal ticket for Flux to review the underlying asset’s drill discrepancy.

Part Audit Report — SSW-112-01-G-S
Footprint correction and verification — 2026-10-19
This section supersedes the earlier footprint scale diagnosis below. The 1000× scale defect was not reproduced: tree computed lengths are SI meters despite computed.unit: mm (the input-unit preference). For example, explicitly setting size: 1.95mm 1.95mm reads back as computed 0.00195, 0.00195, unchanged from before. The 2D SVG explicitly reports millimeters and shows the existing outline at its correct full size. Scaling this geometry 1000× would damage it.
Completed changes
  • All 12 original pad UIDs retained; no pad replacement, terminal, symbol, rotation, or 3D changes.
  • Added explicit source size = 1.95mm 1.95mm, retaining existing copper dimensions and pin-1 rectangle; pads 2–12 remain circular.
  • Added source padHoleType = STD !important, holeSize = 1.04mm 1.04mm !important, holePosition = 0mm 0mm !important on all 12 pads. Important precedence prevents the retained KiCad asset's older 1.3mm drill from winning at runtime.
  • Samtec's single-row PCB layout labels .041 [1.04] DIA (TYP), not .040 [1.02]. Source artifact: https://suddendocs.samtec.com/prints/ssw-s.pdf . A preliminary web scraper gave a conflicting 1.02mm summary; the verified datasheet evidence resolves it as 1.04mm. Finished-hole versus tooling compensation is not established by this evidence.
Readback evidence
All y and z coordinates are zero; rotations are zero. Each row has the common explicit source PTH rules above. Positions below convert the tree's SI meters to millimeters; original positions were preserved.

Table


PinOriginal retained UIDx (mm)
115832273-9757-417f-acc5-a8f89dd424320.00
2937f271d-e5c2-43e1-bec3-360e06aba3552.54
3e0b232b3-d12e-49ed-bbdb-d7bac369d1cb5.08
4925dfe2c-87ef-41e6-98e3-3fce554cfcb77.62
59173757a-ff15-4afc-b8e4-db29ab200d9010.16
66c68e3dc-19c0-40fe-be0e-0dcdc4d706fe12.70
725f9c0dc-0223-46f0-9155-be2aba6bca0d15.24
8f9a398a6-8a61-450e-8b87-67639a766e1317.78
94a592f36-7c6c-4306-92b6-3dfde21b6c4020.32
10d3d1a87c-e545-4798-b286-94eebd315ef622.86
11a0ea9fec-b44e-46e3-8c22-bd56ae8a41c425.40
121cc33d7d-edee-4835-ac6b-89107a213afa27.94
Derived from readback: all 11 adjacent pitches are 2.54mm; end span 27.94mm; circular-pad radial annular ring (1.95−1.04)/2 = 0.455mm; adjacent copper gap 0.59mm.
Associated outline state — no scaling needed
Existing active SVG Silk Shapes node 6d87bba0-d387-48da-83e6-bed282baa396.defaultFootprint.shapes_8147ab76f17da4626ef6323be6940905 contains both the original courtyard and silk paths. 2D millimeter readback gives courtyard centerlines x −1.775 to 29.715, y −1.455 to 1.695: 31.49 × 3.15mm, stroke 0.05mm. Inner silk extents x −1.525 to 29.465, y −1.325 to 1.445: 30.99 × 2.77mm, stroke 0.2mm, retaining the pin-1 corner opening. Existing Fab Shapes node suffix _09b8289606714556af4b6ff9c5cac314 encodes 30.99 × 2.41mm, stroke 0.1mm, but remains disabled by its pre-existing override. Courtyard is bundled into silk, not a separate mechanical clearance object. These pre-existing visibility/layer decisions were preserved, not redesigned.
Checks, remaining uncertainty, and lead handoff
  • Fresh review at 2026-10-19T13:08:06.446Z returned Missing Terminals and Excluded Terminal success, zero errors/warnings.
  • Requested airwire, invalid-pad, invalid-layer and overlapping-copper checks returned no board DRC results in this part project; DRC validation unavailable, not a zero-DRC claim.
  • Source rule readback verifies all 12 hole types and diameters; tree output omits computed hole fields and part-project 2D SVG omits pad geometry. Gerber/drill export or a placed-instance check remains unattempted and is recommended before release to validate rendered/exported holes.
  • Final pad readback additionally contains unit=mm, forceAnnularLayers=All, solderMaskExpansion=0.10mm !important, and solderPasteMaskExpansion=-1.0mm !important. These appeared during the batch without being requested by this worker; lead should confirm their origin and intended application. Rule-source readback also shows connectedLayers=All from system defaults.
  • Source pad work and geometry audit: completed. Outline scaling: not performed because already correct. Full board DRC: unavailable. Exported-hole validation: unattempted. 3D, symbol/metadata cleanup, publishing, and internal ticket: unattempted/outside this batch.
Scope
Reviewed available part metadata, the 12-terminal schematic symbol, PCB footprint, and the official Samtec documentation for SSW-112-01-G-S.
Authoritative sources
Available metadata

Table


FieldCurrent valueAssessment
MPNSSW-112-01-G-SCorrect
ManufacturerSamtecCorrect
Description12 Position, .100" Tiger Buy Socket StripFunctionally correct, but less specific than the official description
Part typeConnectorsCorrect but broad
SubtypeHeaders and Wire HousingsAcceptable
Pin count12Correct
Designator prefixJCorrect
MountSocketDescribes connector style, not mounting technology; official part is vertical through-hole
Datasheet URLhttp://suddendocs.samtec.com/catalog_english/ssw_th.pdfPresent and official; no update required
Package / case codeNot setMissing
Connector pitch/rows/positions/genderNot setMissing useful structured metadata
Key specifications
  • Connector: Tiger Buy socket-strip receptacle, vertical through-hole solder tail
  • Contacts: 12 positions, 1 row
  • Pitch: 2.54 mm (0.100 in)
  • Lead style: -01, 2.64 mm (0.104 in) tail
  • Plating option -G: 20 µin gold in contact area, 3 µin gold on tail
  • Body length: 30.99 ± 0.25 mm (1.220 ± 0.010 in)
  • Body width: 2.41 mm (0.095 in) reference
  • Body height: 8.51 mm (0.335 in)
  • Tail section: 0.79 × 0.41 mm (0.031 × 0.016 in), reference
  • Recommended footprint: 12 plated through-holes in one row, 2.54 mm pitch, Ø1.04 mm drill; pin 1-to-pin 12 span 27.94 mm
  • Contact material: phosphor bronze; black UL94 V-0 liquid-crystal-polymer insulator for the -S row option
  • Catalog rating: 4.7 A per pin with two pins powered; 465 VAC / 655 VDC; -55 °C to +125 °C for gold-plated variants
Schematic symbol cross-check
Correct
  • Exactly 12 terminals are present.
  • Terminal numbers 1 through 12 are present once each.
  • A passive 1×12 connector does not require unique signal names for each contact.
Mismatches / omissions
  • Every terminal has Pin Type = Unspecified. Connector contacts should normally be Passive.
  • No terminal has a useful Pin Description. Recommended descriptions are “Contact 1” through “Contact 12” (or equivalent).
  • The symbol is represented as independent terminal objects rather than a clearly bounded connector body. Electrically usable, but less readable and less obviously associated as one 12-position connector.
Footprint cross-check
Required by Samtec
  • 12 plated through-holes, single straight row
  • 2.54 mm pitch
  • Ø1.04 mm drill, typical
  • 27.94 mm center span from pin 1 to pin 12
  • Approximate body outline 30.99 × 2.41 mm
  • Pin-1 identification
Current footprint findings
  • 12 pad nodes exist and pin 1 is rectangular, which provides a pin-1 cue.
  • The reported pad centers are spaced 0.00254 mm, not 2.54 mm.
  • The reported end-to-end span is 0.02794 mm, not 27.94 mm.
  • Reported pad size is approximately 0.00195 mm, not a practical through-hole pad diameter.
  • No drill/hole-size property is present on the inspected pad nodes, so the required Ø1.04 mm plated holes are not defined.
  • No mechanical body outline or courtyard was found.
  • Reference/value silkscreen text is reported at a similarly incorrect scale and overlaps the footprint origin.
Severity: Critical. The footprint appears to be scaled approximately 1000× too small and lacks the required plated-through drill definition. It is not manufacturable or mechanically compatible with the connector as currently represented.
Overall verdict
  • Identity and pin count: Correct.
  • Datasheet: Already set to an official Samtec URL; no property update was necessary.
  • Symbol: Numbering is correct, but pin types and descriptions are incomplete.
  • Footprint: Critical mismatch; must be rebuilt or corrected before use.
  • Metadata: Core identity is correct, but package and connector-specific structured properties are incomplete.
  1. Rebuild the footprint at 2.54 mm pitch with 12 PTH pads and Ø1.04 mm drills.
  2. Choose a manufacturable copper pad diameter that provides adequate annular ring under the target fabricator’s rules; Samtec specifies the drill but not copper diameter in the referenced footprint drawing.
  3. Add the 30.99 × 2.41 mm nominal body outline, courtyard, and clear pin-1 marking.
  4. Set all symbol terminals to Passive and add “Contact N” pin descriptions.
  5. Add structured metadata: Through Hole mount, 2.54 mm pitch, 12 positions, 1 row, receptacle/socket gender, and a meaningful package/case label.
  • Footprint correction and verification — 2026-10-19

  • Completed changes

  • Readback evidence

  • Associated outline state — no scaling needed

  • Checks, remaining uncertainty, and lead handoff

  • Scope

  • Authoritative sources

  • Available metadata

  • Key specifications

  • Schematic symbol cross-check

  • Correct

  • Mismatches / omissions

  • Footprint cross-check

  • Required by Samtec

  • Current footprint findings

  • Overall verdict

  • Recommended corrections