Footprint Scale Verification


Please fix this, based from this flag issue:
Audit found the imported footprint is parsed about 1000x too small in Flux (e.g. 12.065 mm source coordinate becomes 0.012065 mm; 0.74 mm pad becomes 0.00074 mm).
I’ll check the imported dimensions, correct the footprint’s scale, and verify the pad sizes and spacing against the source geometry.
Thought for 7 mins 45 sec
Thought for 7 sec
Created 2 tasks.
1/2 Inspect and correct the imported footprint’s unit scale.

Inspect and correct the imported footprint’s unit scale.

Verify corrected geometry and report the import defect.

Thought for 12 sec
Awaiting 1 task
"Footprint Scale Verification" completed.
The scale flag is a false positive: the computed values are in meters, not millimeters; native export confirms all 40 pads are 0.740 × 2.220 mm, with endpoint centers at ±12.065 mm. I left the geometry unchanged—scaling it by 1000 would break it—and documented the evidence in Footprint Scale Verification.
Separate mask-expansion and disabled-artwork discrepancies remain; those should be reviewed next, rather than rescaling the footprint.

Part Audit Report — SAMTEC-SFM-120-02-X-D
Scope and sources
Reviewed the part-level metadata, 40-terminal schematic symbol, imported KiCad footprint, pad numbering, and available properties. Primary source: Samtec official SFM series catalog/drawing: https://suddendocs.samtec.com/catalog_english/sfm.pdf
Metadata audit

Table


FieldCurrent stateAssessment
Manufacturer Part NumberSAMTEC-SFM-120-02-X-DSeries/configuration template, not a complete orderable MPN because X is an unresolved plating placeholder. Resolve to an allowed plating code before procurement.
Manufacturer NameMissingShould be Samtec.
Part TypeMissing at connector levelShould identify a connector/receptacle/socket. Individual symbol terminals are correctly typed as passive terminals.
Datasheet URLSetThe Datasheet property now resolves to an uploaded copy of the official Samtec SFM PDF. Authoritative source URL: https://suddendocs.samtec.com/catalog_english/sfm.pdf
Designator PrefixJAppropriate for a connector.
PackageMissingThe footprint represents a vertical SMT, double-row SFM receptacle, but this is not recorded as a formal property.
DescriptionOnly the MPN/project nameA functional description is missing.
3D modelNoneNo STEP/WRL/GLB model is attached.
MPN interpretation
  • SFM: Samtec SFM Tiger Eye receptacle/socket series.
  • 120: 20 positions per row.
  • 02: vertical surface-mount contact style.
  • X: unresolved plating placeholder; not a final orderable code.
  • D: double row.
  • Total contact count: 40.
Key family specifications
  • Connector: female receptacle/socket, vertical SMT, double row.
  • Pitch: 1.27 mm (0.050 in).
  • Contacts: 40 total, 20 per row.
  • Contact material: beryllium copper for the -02 Tiger Eye contact style.
  • Insulator: black liquid-crystal polymer.
  • Operating temperature: -55 °C to +125 °C.
  • Maximum working voltage listed for the family: 250 VAC / 354 VDC.
  • Plating must be resolved from the valid ordering options before purchasing.
Schematic symbol cross-check
  • Exactly 40 terminals exist, numbered 1 through 40.
  • All terminals are passive, which is correct for an uncommitted connector.
  • No duplicate or missing terminal numbers were found.
  • Terminal descriptions contain only numeric pin names; no descriptive text is present. This is acceptable electrically for a generic connector but weak metadata.
  • Pin Group, Pin Orientation, and Section metadata are absent.
  • The rendered symbol text appears corrupted/unreadable even though the terminal inventory is complete.
Footprint cross-check
Correct or consistent features
  • 40 SMD pads are present and numbered 1 through 40.
  • Arrangement is 20 columns by 2 rows.
  • Longitudinal pad pitch is 1.270 mm.
  • First-to-last pad-center span is 24.130 mm.
  • Pad width is 0.740 mm.
  • Odd pins occupy one row and even pins the other, paired by column; this is consistent with the expected interleaved numbering convention, subject to footprint-view mirroring/rotation.
Confirmed or likely mismatches
  1. Severe Flux scale/unit defect: the parsed footprint is approximately 1000× too small. For example, a source position of 12.065 mm is represented as 0.012065 mm and a 0.74 mm pad width as 0.00074 mm. The footprint is not manufacturable in this state.
  2. Pad length: imported value is 2.220 mm; the reviewed Samtec recommended pattern indicates approximately 1.520 mm.
  3. Row-center spacing: imported value is 2.730 mm; the reviewed official pattern indicates approximately 3.050 mm.
  4. The imported inner pad gap remains 0.510 mm, suggesting the source geometry preserved the gap while changing both row spacing and pad length.
  5. Outline: imported silkscreen is approximately 30.238 × 5.852 mm, larger than the approximately 29.21 × 4.95 mm connector outline for 20 positions. It should not be treated as an exact body outline.
  6. The footprint includes dimension annotations and fabrication-drawing content as PCB text, rather than a clean production footprint.
  7. No 3D package model is attached for mechanical verification.
Overall disposition
Do not publish or use this footprint for fabrication in its current state. Pin count and numbering are complete, but the footprint has a critical scale defect and likely land-pattern geometry mismatches. The MPN also needs a real plating code before it represents an orderable component. The Datasheet property is now populated from the official Samtec source.
  • Scope and sources

  • Metadata audit

  • MPN interpretation

  • Key family specifications

  • Schematic symbol cross-check

  • Footprint cross-check

  • Correct or consistent features

  • Confirmed or likely mismatches

  • Overall disposition