I’ll research the manufacturer’s specifications and sourcing options, then create a cited application and usage guide with practical PCB guidance and clearly labeled alternatives.
I verified the published product specifications and reel quantities, but the datasheet lookup has not returned usable evidence after two attempts. I’ll distinguish the verified product-page facts from unresolved drawing details and label the alternatives as functional substitutes—not drop-in replacements.
The Harwin S2761-46R is a single-contact, surface-mount PCB test point with a brass body and tin-over-nickel finish, intended to provide an accessible electrical measurement location. Its most common use is probing power rails, ground, and low-speed signals during PCB bring-up, production testing, and service using test probes or miniature clips and hooks. Harwin product page
Verification scope: Manufacturer product-page specifications and the alternative manufacturers’ product pages were verified on October 6, 2026. The component’s datasheet evidence lookup remained pending after two attempts; drawing-specific pad dimensions, tolerances, revision/date, voltage rating, and manufacturer contact num...
Created the S2761-46R Application and Usage Guide with all seven requested sections, source links, practical wiring/layout guidance, and two functional alternatives. Exact land-pattern dimensions and drawing revision remain unverified after two datasheet lookup attempts; these gaps are explicitly flagged, and neither alternative is claimed as a drop-in replacement.
The Harwin S2761-46R is a single-contact, surface-mount PCB test point with a brass body and tin-over-nickel finish, intended to provide an accessible electrical measurement location. Its most common use is probing power rails, ground, and low-speed signals during PCB bring-up, production testing, and service using test probes or miniature clips and hooks. Harwin product page
Verification scope: Manufacturer product-page specifications and the alternative manufacturers’ product pages were verified on October 6, 2026. The component’s datasheet evidence lookup remained pending after two attempts; drawing-specific pad dimensions, tolerances, revision/date, voltage rating, and manufacturer contact numbering therefore remain unverified. Recommendations below are engineering integration guidance, not additional manufacturer ratings; this guide does not certify the current Flux footprint.
1. Quick Specifications
This passive metal test terminal has no supply voltage or logic operating mode. Do not treat its published current rating as an IC-style absolute-maximum table or assume full rated current is permissible across the entire operating-temperature range.
Table
Parameter
Published value / status
Rating category and practical interpretation
Component type
SMT PCB test point, 1 signal contact
Passive measurement terminal; not a two-terminal series component. Harwin
Current
3.5 A
Manufacturer current rating; test conditions and temperature derating were not verified. It is not a blanket rating for the attached probe, PCB trace, or solder joint. Harwin
Operating temperature
−55°C to +125°C
Published operating range, not a soldering range. Harwin
Soldering limit
Maximum 260°C for 10 seconds
Assembly-process limit, not a recommended operating condition. Validate the complete reflow profile with the assembler. Harwin
Nominal dimensions
1.60 × 0.80 × 1.15 mm
Product dimensions; drawing tolerances not verified. Harwin
Height above PCB
1.15 mm
Published height; allow additional access space for the probe or clip. Harwin
Package/footprint designation
1608 metric / 0603 imperial
Manufacturer size designation; do not substitute a two-pad resistor footprint. Exact recommended copper and paste geometry remains unverified. Harwin
Contact pitch
Not applicable between contacts
Only one signal contact. Carrier-tape pitch is a separate assembly parameter and was not verified.
Do not infer high-voltage suitability from current rating or metal construction. Board clearance, insulation, instrument rating, and accessibility govern safe use.
Absolute maximum ratings
No separately verified table
The available product page gives current, temperature, and soldering data; this is not evidence that other limits do not exist.
Typical operating conditions
Application-dependent
Common voltage-measurement use draws instrument input current, rather than the board’s load current, through the test terminal.
2. Pinout & Connections
Table
Pin Number
Pin Name
Description
Best Practice
One electrical contact; manufacturer numeric designation unverified
TP / measured net; user-assigned name
Conductive test terminal connected to one PCB net
Connect directly to the exact node being measured. Tie to GND only when this is intentionally a ground test point. No pull-up, pull-down, or bypass capacitor is required by the terminal itself.
For a new schematic symbol, a single terminal numbered 1 is a reasonable CAD convention, but it is not a verified manufacturer pin number. Check that the schematic terminal identifier matches the footprint’s electrical pad identifier before publishing or using the library part.
3. Standard Application Circuit
Typical power-rail measurement setup: Keep the normal power path from regulator output to loads intact. Add a short copper branch from the output measurement node to a test point labeled TP_3V3, and place a separate ground test point labeled TP_GND nearby. Attach the meter’s positive lead to TP_3V3 and its return lead to TP_GND.
For regulator ripple measurements, connect at the output capacitor’s rail node and use a short local ground connection. Existing regulator decoupling and output capacitors remain required by the regulator, not by this test point; do not add a capacitor solely to support the terminal, since it can change the measured circuit.
Required support components: None for the test terminal itself. Any pull-ups, filtering, protection, or current-limiting elements are requirements of the underlying circuit and test procedure.
Measurement precautions:
Use a high-impedance instrument for voltage probing. For fast edges, instrument input capacitance and the test-point branch can affect the waveform.
Do not measure current by placing an ammeter between a rail test point and ground; this can short the supply. Measure through an intentional series break or a properly designed current-sense element instead.
If injecting power through the terminal, confirm that the source will not backfeed a regulator or another supply, limit current, and qualify the terminal, probe, solder joint, and copper path together. The published terminal current rating alone is insufficient.
Use a miniature clip or hook that actually fits. Harwin identifies this size for miniature clips in its SMT test-point training module.
These are engineering measurement recommendations; no manufacturer-specific measurement bandwidth or safe injection-current derating was verified.
4. PCB Layout & Routing Guidelines
Use the correct one-net land pattern: Verify the recommended PCB pattern against Harwin’s S2761R drawing before releasing manufacturing data. The 0603/1608 designation describes size, not permission to use a standard two-pad passive footprint. Copper, solder-mask, and stencil apertures must suit the actual solderable base; exact dimensions remain unresolved.
Provide real probe access: Place the terminal where a probe or miniature hook can approach without contacting adjacent live copper. Keep silkscreen identification outside the solderable land, allow enclosure access, and support the board against probe force. Harwin specifies miniature-clip use and 1.15 mm height. Harwin product page
Keep measurement branches short: Locate a nearby ground return for oscilloscope measurements. Avoid long stubs on fast clocks, RF nets, and differential pairs; this is not a controlled-impedance or differential-probe connector. If access to a fast pair is necessary, evaluate both electrical loading and symmetry rather than simply attaching two terminals.
Size copper for its actual role: A voltage-sense branch normally does not carry the load current. If using the terminal to inject or draw test current, size traces, vias, neckdowns, and plane connections for copper thickness, acceptable temperature rise, and test duration. No universal trace width can be specified without those inputs.
Balance plane connection and solderability: On a plane-connected ground terminal, use thermal relief only after confirming adequate spoke current capacity and acceptable measurement return impedance; a solid connection may require reflow-profile tuning. Do not relocate the circuit’s decoupling capacitors to make room for the test point—place the test point around the required capacitor/IC geometry.
Layout bullets are engineering guidance, not additional drawing specifications or a completed footprint audit.
5. Common Pitfalls / Things to Watch Out For
Treating “0603” as an ordinary resistor footprint or ignoring clip clearance. A two-pad passive land pattern is not automatically suitable for a one-contact terminal. Verify the manufacturer drawing, terminal-to-pad mapping, solder coverage, and installed probe envelope; lateral clip force can stress the solder joint or lift the land.
Confusing voltage access with a rated power connector. The published 3.5 A current rating does not qualify every probe/trace combination or establish voltage insulation. Incorrect ammeter placement can short a rail, and an earth-referenced oscilloscope ground clip can short a non-ground node. Check the instrument connection and the full current/return path before energizing.
6. Popular Alternatives & Equivalents
No verified cross-manufacturer drop-in replacement was established. The following are verified SMT test-point products from another manufacturer, but must be treated as functional alternatives requiring footprint and mechanical review. Do not reuse the Harwin 3.5 A rating for either alternative.
Table
Manufacturer / part
Verified characteristics
Compatibility classification
Keystone Electronics 5015
Micro-mini SMT test point; phosphor bronze, silver plate; 1,000 pieces per 7-inch tape-and-reel pack. Manufacturer product page
Functionally similar only. One-net test access is analogous; pin numbering and land-pattern interchangeability were not verified. Use its own manufacturer footprint and validate clip access.
Keystone Electronics 5191TR
Black, color-keyed SMT loop test point; silver-plated phosphor-bronze terminal and LCP base; tape-and-reel supply. Intended for test probes, hooks, and clips. Manufacturer family table
Functionally similar only. Different loop/base construction; footprint replacement and access-envelope review required. Not a verified pin- or footprint-compatible substitute.
Neither exact alternative was verified in the Flux library during this lookup, so no verified Flux-library part link is provided. The manufacturer links above establish the products’ existence and function, not interchangeability or popularity rankings.
7. Sourcing & Purchasing Guide
Table
Attribute
Details
Primary Distributors
Verified direct listings include TTI and LCSC, C5846954. DigiKey’s Harwin product overview lists this component and cut-tape offerings. Confirm regional availability and franchised status directly with Harwin; a listing alone does not prove authorization.
Packaging Options
Harwin specifies tape and reel. Distributor cut-tape supply is available through the cited DigiKey overview; cut tape and a factory full reel are different purchasing formats of the same manufacturer ordering code. Harwin
Standard MOQ
Distributor-dependent, not one universal manufacturer MOQ: TTI lists a 3,000-piece minimum and 3,000-piece multiples; LCSC lists a 5-piece minimum and 3,000-piece full-reel packaging. Confirm small-quantity cut-tape MOQ with the selected distributor rather than assuming 1 piece. TTI · LCSC
Assembly sourcing
JLCPCB C5846954 lists the part as Extended, minimum 1 and full reel 3,000. This is an assembly-service listing, not proof that standalone component purchases ship to the buyer. Class, fees, and available assembly quantity can change.
Sourcing Advice
Order the complete MPN S2761-46R and specify required cut tape versus factory reel. Verify finish, package, traceability, and feeder requirements against the manufacturer drawing and order acknowledgement. Prefer manufacturer-confirmed franchised distributors; unauthorised marketplace listings can create counterfeit, substitution, and traceability risks. Do not accept a similarly named part as a drop-in replacement without its drawing and ratings.
Purchasing information is a lookup snapshot dated October 6, 2026, not a stock reservation or quote. Prices and stock quantities are intentionally omitted because they change frequently.
Sources
Harwin — S2761-46R official product page:https://www.harwin.com/products/S2761-46R. Primary source for published dimensions, current, operating temperature, soldering limit, materials, plating, and tape-and-reel format. Page revision/date not shown in retrieved content.
Harwin — S2761R.pdf technical drawing/datasheet: Linked in the official product page’s Downloads section. A directly accessible distributor-hosted copy is https://www.lcsc.com/datasheet/lcsc_datasheet_2501061605_Harwin-S2761-46R_C5846954.pdf. Drawing revision/date and exact drawing content were not verified; the distributor filename timestamp must not be treated as the manufacturer revision date.
Before design release: Obtain the current Harwin drawing, resolve pad geometry/tolerances and voltage/current test conditions for the intended use, and check the actual library footprint. Those unresolved items are explicitly not inferred from the screen capture or the project description.