Part Review Report
RV-8803-C7 Part Information Review
Table
| Field | Current value |
|---|---|
| Project / part name | RV-8803-C7 |
| Published part UID | 9417cad8-9f44-49c6-ae54-a63d0876d97f |
| Description | Real-Time Clock Module |
| Manufacturer Part Number | RV-8803-C7 |
| Manufacturer Name | Micro Crystal AG |
| Designator Prefix | Y |
| Package or Case Code | Module |
| Datasheet URL | ef2fd096a345d1785a9ba8b7753a43271fc9a655d546752574d394a6e6c9623a.pdf |
| Terminal / pad count | 8 |
| BOM items | 0, expected for this terminal-based part project |
Table
| Parameter | Datasheet value |
|---|---|
| Function | SMT real-time clock module with integrated CMOS RTC IC and 32.768 kHz crystal |
| Interface | I2C-bus, Fast Mode up to 400 kHz |
| I2C address | 7-bit 0x32; write 0x64, read 0x65 |
| Supply voltage | 1.5 V to 5.5 V for timekeeping and 100 kHz I2C; 2.0 V to 5.5 V for 400 kHz I2C |
| Timekeeping current | 240 nA typ at 3 V, I2C inactive, CLKOUT disabled; datasheet extraction also reports max values up to 600 nA at 1.5/3 V and 700 nA at 5 V |
| Accuracy | +/-3 ppm from -40°C to +85°C; +/-7 ppm from +85°C to +105°C with limitations |
| Aging | +/-3 ppm max first year at 25°C |
| Clock output | 32.768 kHz default, 1024 Hz, or 1 Hz; controlled by CLKOE |
| Package | C7, 3.2 mm x 1.5 mm x 0.8 mm |
| Recommended solder pads | 8 pads, 2 x 4; 0.5 mm x 0.8 mm pads; 0.9 mm horizontal pitch; 0.4 mm gap between rows |
| Lid connection | Metal lid connected to VSS, pin 5 |
Table
| Pin | Flux terminal | Datasheet terminal | Datasheet description | Result |
|---|---|---|---|---|
| 1 | SDA | SDA | Serial Data | Match |
| 2 | CLKOUT | CLKOUT | Clock Output | Match |
| 3 | VDD | VDD | Power Supply Voltage | Match |
| 4 | CLKOE | CLKOE | Clock Output Enable | Match |
| 5 | VSS | VSS | Ground | Match |
| 6 | ~INT | INT | Interrupt Output | Functional match; naming differs by active-low marker |
| 7 | EVI | EVI | Event Input | Match |
| 8 | SCL | SCL | Serial Clock Input | Match |
~INT while the datasheet labels the pin INT. This is acceptable if the symbol convention intentionally marks active-low interrupt behavior, but it is not the exact datasheet label.Unspecified; these could be improved for ERC quality.Table
| Severity | Area | Finding | Recommendation |
|---|---|---|---|
| Warning | Metadata | Part Type is not set. | Set Part Type to Integrated Circuit, RTC, or a platform-supported RTC/clock category if available. |
| Warning | Metadata | Package or Case Code is only Module, while the datasheet calls out C7 / SON-8, 3.2 x 1.5 x 0.8 mm. | Refine package metadata to C7 / SON-8, 3.2 x 1.5 x 0.8 mm if supported. |
| Info | Datasheet URL | Existing property points to an uploaded PDF copy; official manufacturer URL was found. | Prefer the official Micro Crystal PDF URL for long-term traceability if Flux allows replacing the current value. |
| Info | Symbol naming | Pin 6 is named ~INT; datasheet label is INT. | Keep if intentional to show active-low behavior; otherwise rename to exact datasheet label and document polarity separately. |
| Info | Symbol metadata | All terminal Pin Type properties are Unspecified. | Add pin electrical types to improve ERC and part quality. |
| Info | Package note | Datasheet states metal lid is connected to VSS pin 5, but no visible metadata note was found. | Add a role/details note or package note: Metal lid connected to VSS / pin 5. |
Scope
Current part information in Flux
Datasheet key specifications
Symbol pin cross-check
Footprint cross-check
Review check results
Mismatches / issues flagged
Conclusion