Chat
Welcome to Flux
Treat Flux like your intern. Tell it what you'd like to build and it'll get to work. You can also ask it questions, brainstorm ideas, and teach it your preferences. Learn More
datasheet_url; the official URL was set to:Table
| Field | Project value | Datasheet cross-check |
|---|---|---|
| MPN | TMAG5231C1DQDBZR | Correct |
| Manufacturer | Texas Instruments | Correct |
| Part type | Sensor | Correct, more specifically a low-power Hall-effect switch |
| Pin count | 3 | Correct for DBZ SOT-23 |
| Designator prefix | U | Appropriate |
| Mount | Surface mount | Correct |
| Package library field | SOT-23-5 | Mismatch: this orderable part is DBZ, 3-pin SOT-23 |
| Datasheet | Official TI URL added | Correct |
Table
| Pin | Symbol name | Symbol type | Datasheet function | Result |
|---|---|---|---|---|
| 1 | VCC | Power In | 1.65–5.5 V supply; connect at least 0.1 µF ceramic to GND | Number/name correct; description missing |
| 2 | OUT | Output | Omnipolar output responding to north and south poles | Correct; description missing |
| 3 | GND | Power In | Ground reference | Number/name correct; description missing; Ground type would be clearer |
SOT95P237X112-3N.kicad_modTable
| Feature | Effective footprint | TI recommended land pattern | Result |
|---|---|---|---|
| Pad count | 3 | 3 | Correct |
| Pad size | 1.24 × 0.59 mm | 1.30 × 0.60 mm | Slightly undersized by 0.06 × 0.01 mm |
| Two-pin-side pitch | 0.95 mm | 0.95 mm | Correct |
| Two-pin center separation | 1.90 mm | 1.90 mm | Correct |
| Opposing-side center span | 2.11 mm | 2.10 mm | +0.01 mm, negligible |
| Fab body | 2.92 × 1.30 mm | Nominal 2.92 × 1.30 mm | Correct |
| Solder paste | Present, nominally 1:1 | Stencil example matches pad geometry | Acceptable |
| Solder mask | +0.102 mm expansion | TI example shows 0.07 mm clearance | Larger than TI example; verify against fab capability |
SOT-23-5, but this device is a 3-pin SOT-23, TI DBZ package.Power In rather than Ground.Result
Part metadata
Variant key specifications
Symbol and pin audit
Footprint audit
Description/property mismatches
Overall assessment