I reviewed the datasheet and concluded that your finding is incorrect, as the drawing clearly shows three holes with a 1.7 mm diameter. Please re-check the datasheet and update the audit accordingly.
You’re right to challenge that finding. I’ll re-read the drawing’s hole callout, compare it directly with the three signal-pad drill sizes, and correct the audit record and any related issue report.
Part AuditMR30PW-M — corrected reviewFootprint geometry
Pads 1, 2, and 3: Ø1.70 mm drilled holes with Ø2.55 mm copper pads.
Contact pitch: 3.50 mm between adjacent electrical contacts.
MH1 and MH2: Ø1.00 mm drilled mechanical mounting holes.
Conclusion: The three electrical contact-hole diameters match the manufacturer drawing. The previous finding that Ø1.90 mm holes were required was incorrect and is withdrawn. The comparison had relied on a third-party footprint rather than the MR30PW-M drawing.
Remaining audit flags
Package metadata value TO is not appropriate for this through-hole power connector.
Electrical pins and mounting holes lack clear pin descriptions/types; MH1 and MH2 should be identified as mechanical.
You are correct. The drawing specifies 3 × Ø1.7 mm contact holes, and pads 1–3 use 1.70 mm drills, so the footprint matches. The previous Ø1.9 mm mismatch finding is withdrawn.
I recorded the corrected conclusions in the Part Audit. The remaining metadata, pin-description, and 3D-model flags are unchanged.
Pads 1, 2, and 3: Ø1.70 mm drilled holes with Ø2.55 mm copper pads.
Contact pitch: 3.50 mm between adjacent electrical contacts.
MH1 and MH2: Ø1.00 mm drilled mechanical mounting holes.
Conclusion: The three electrical contact-hole diameters match the manufacturer drawing. The previous finding that Ø1.90 mm holes were required was incorrect and is withdrawn. The comparison had relied on a third-party footprint rather than the MR30PW-M drawing.
Remaining audit flags
Package metadata value TO is not appropriate for this through-hole power connector.
Electrical pins and mounting holes lack clear pin descriptions/types; MH1 and MH2 should be identified as mechanical.
Confirm the attached 3D model represents the male MR30PW-M variant; its asset naming previously suggested a female variant.
General connector properties and ratings should be populated consistently if a complete parametric record is required.
Verification status
Footprint drill sizes were read directly from the current footprint. Datasheet evidence indexing was unavailable during this correction, so the mechanical drawing was re-checked visually; it clearly calls out 3 × Ø1.7 mm for the electrical contact holes.