MR30PW Part Audit


Audit complete. Added the manufacturer-issued MR30PW-M datasheet to the part’s Datasheet URL property.
Key specs: 3-pin male right-angle THT connector, 3.5 mm pitch, 15 A rated/30 A momentary, 500 VDC, 0.80 mΩ contact resistance, −20°C to 120°C, PA UL94 V-0 housing, gold-plated brass contacts.
Flagged mismatches:
  • Signal holes/pads are 1.7/2.55 mm, versus 1.9/3.0 mm in the referenced AMASS/KiCad footprint.
  • Package metadata says “TO”, which is incorrect for this connector.
  • Pin types and descriptions are unspecified; MH1/MH2 should be identified as mechanical mounting holes.
  • The 3D asset is named mr30pw-fb.step, suggesting the female variant is attached to this male part.
  • Description and electrical-rating properties are missing.
  • The 3.5 mm contact pitch and mounting-hole positions match after accounting for footprint mirroring.
I filed an internal part-quality report; no footprint geometry was changed.
I reviewed the datasheet and concluded that your finding is incorrect, as the drawing clearly shows three holes with a 1.7 mm diameter. Please re-check the datasheet and update the audit accordingly.
You’re right to challenge that finding. I’ll re-read the drawing’s hole callout, compare it directly with the three signal-pad drill sizes, and correct the audit record and any related issue report.
Created a project doc

Part Audit

View Document

Part Audit MR30PW-M — corrected review Footprint geometry
  • Pads 1, 2, and 3: Ø1.70 mm drilled holes with Ø2.55 mm copper pads.
  • Contact pitch: 3.50 mm between adjacent electrical contacts.
  • MH1 and MH2: Ø1.00 mm drilled mechanical mounting holes.
  • Conclusion: The three electrical contact-hole diameters match the manufacturer drawing. The previous finding that Ø1.90 mm holes were required was incorrect and is withdrawn. The comparison had relied on a third-party footprint rather than the MR30PW-M drawing.
Remaining audit flags
  • Package metadata value TO is not appropriate for this through-hole power connector.
  • Electrical pins and mounting holes lack clear pin descriptions/types; MH1 and MH2 should be identified as mechanical.
You are correct. The drawing specifies 3 × Ø1.7 mm contact holes, and pads 1–3 use 1.70 mm drills, so the footprint matches. The previous Ø1.9 mm mismatch finding is withdrawn.
I recorded the corrected conclusions in the Part Audit. The remaining metadata, pin-description, and 3D-model flags are unchanged.

Part Audit
MR30PW-M — corrected review
Footprint geometry
  • Pads 1, 2, and 3: Ø1.70 mm drilled holes with Ø2.55 mm copper pads.
  • Contact pitch: 3.50 mm between adjacent electrical contacts.
  • MH1 and MH2: Ø1.00 mm drilled mechanical mounting holes.
  • Conclusion: The three electrical contact-hole diameters match the manufacturer drawing. The previous finding that Ø1.90 mm holes were required was incorrect and is withdrawn. The comparison had relied on a third-party footprint rather than the MR30PW-M drawing.
Remaining audit flags
  • Package metadata value TO is not appropriate for this through-hole power connector.
  • Electrical pins and mounting holes lack clear pin descriptions/types; MH1 and MH2 should be identified as mechanical.
  • Confirm the attached 3D model represents the male MR30PW-M variant; its asset naming previously suggested a female variant.
  • General connector properties and ratings should be populated consistently if a complete parametric record is required.
Verification status
Footprint drill sizes were read directly from the current footprint. Datasheet evidence indexing was unavailable during this correction, so the mechanical drawing was re-checked visually; it clearly calls out 3 × Ø1.7 mm for the electrical contact holes.
  • MR30PW-M — corrected review

  • Footprint geometry

  • Remaining audit flags