Part Audit Report
Part Audit Report — FS12-500-C2
N/A / Manufacturer Recommendations / Triad Magnetics — incomplete and not a useful functional description.N/A / Manufacturer Recommendations / Triad Magnetics — incomplete and not a useful functional description.Table
| Parameter | Official value |
|---|---|
| Transformer type | Class 2, split-bobbin, dual-primary / dual-secondary PCB transformer |
| Maximum power | 6.0 VA |
| Primary | 115 VAC with windings in parallel; 230 VAC with windings in series |
| Frequency | 50/60 Hz |
| Secondaries | Two independent 6.3 VAC, 0.5 A windings |
| Series secondary configuration | 12.6 VAC at 0.5 A |
| Parallel secondary configuration | 6.3 VAC at 1.0 A |
| Typical regulation | 25% full-load to no-load |
| Operating temperature | -40 °C to +100 °C |
| Storage temperature | -55 °C to +150 °C |
| Primary-secondary hipot | 4200 VRMS |
| Secondary-secondary hipot | 2160 VRMS |
| Insulation system | UL Class F, 155 °C |
| Body maximum | 1.650 × 1.331 × 1.398 in (L × W × H) |
| Weight | 0.44 lb |
| Approvals | UL/cUL file E65390; TÜV certificate R72120839 |
Table
| Pins | Function | Polarity / phase |
|---|---|---|
| 1–2 | Primary winding 1 | Pin 1 is dotted |
| 3–4 | Primary winding 2 | Pin 3 is dotted |
| 5–6 | Secondary winding 1, 6.3 V / 0.5 A | Pin 5 is dotted |
| 7–8 | Secondary winding 2, 6.3 V / 0.5 A | Pin 7 is dotted |
Triad Magnetics.Power Transformer.Through Hole / PCB Mount Split Pack.6 VA split-bobbin power transformer; dual 115 V primaries for 115/230 V operation; dual 6.3 V, 0.5 A secondaries; Class 2 PCB through-hole.Audit status
Key specifications
Datasheet pin mapping
Symbol cross-check
Correct
Mismatches / omissions
Footprint cross-check
Matches the official board layout
Notes
Recommended metadata corrections
Overall conclusion