Part Verification and Datasheet Update


Review all available part information (MPN, package, pin count, description, properties). If no datasheet URL is already set, search the web for the official datasheet and update the part's Datasheet property with the URL. Then cross-check the schematic symbol, footprint, and pin descriptions against the datasheet. Summarize key specs and flag any mismatches.
I’ll inspect the part project’s schematic/layout/properties, find or verify the official datasheet URL, update it if missing, then cross-check pins and footprint against the datasheet.
Found the official Vishay CRCW-HP e3 datasheet and added its URL to the part project. I’m now checking the symbol and footprint details against it.
Completed the part review for CRCW2512499RFKEGHP. I added the official Vishay datasheet URL and created a detailed verification report: part-verification-report-crcw2512499rfkeghp.
Open items:
  • Pin descriptions are blank/undefined.
  • Metadata is missing parsed specs like 499 Ω, ±1%, 1.5 W, ±100 ppm/K, and manufacturer.
  • Footprint is close to Vishay’s reflow land pattern, but pad span/gap are slightly smaller than the datasheet recommendation.
Suggested next steps:
  1. Add the missing part properties for library completeness.
  2. Populate terminal pin descriptions.
  3. Optionally tune the footprint to exactly match Vishay’s recommended 2512 reflow pads.
Fix metadata and footprint
Add missing properties
Populate pin descriptions
Tune footprint pads
Run verification review

Part Verification Report — CRCW2512499RFKEGHP
Source reviewed
Project part information observed
  • Project / part name: CRCW2512499RFKEGHP
  • Manufacturer Part Number: CRCW2512499RFKEGHP
  • Package or Case Code: R2512
  • Published part UID: ff0ceb22-0596-4955-8a0d-96cb7e0f270d
  • Schematic terminals: 2 passive terminals; pin numbers 1 and 2
  • Footprint asset: RESC6331X70N.kicad_mod
  • 3D model asset: CRCW2512499RFKEGHP.step
Key datasheet specs for CRCW2512-HP e3
  • Type / size: CRCW2512-HP e3, imperial 2512, metric RR6332M
  • Resistance range: 1 Ω to 1 MΩ; jumper option
  • Parsed MPN value: 499R = 499 Ω
  • Tolerance code F: ±1%
  • TCR code K: ±100 ppm/K
  • Rated dissipation P70: 1.5 W
  • Rated dissipation at terminal part temperature 105 °C: 2 W
  • Max operating voltage: 500 V ACRMS/DC
  • Operating temperature range: -55 °C to +155 °C
  • Max permissible film temperature: 155 °C
  • Body dimensions: L 6.3 ±0.20 mm, W 3.15 ±0.15 mm, H 0.6 ±0.10 mm
  • Terminal dimensions: T1 0.6 ±0.20 mm, T2 0.6 ±0.20 mm
  • Recommended reflow solder pads for 2512: G 5.00 mm, Y 1.25 mm, X 3.35 mm, Z 7.50 mm
  • Recommended wave solder pads for 2512: G 4.90 mm, Y 1.60 mm, X 3.50 mm, Z 8.10 mm
Symbol cross-check
  • Datasheet expectation: two-terminal passive chip resistor.
  • Project symbol: two passive terminals, pin numbers 1 and 2.
  • Result: Matches electrically.
  • Issue: Pin descriptions are not populated; for a resistor this is low-risk, but pin descriptions should ideally be “Terminal 1” and “Terminal 2” for library completeness.
Footprint cross-check
  • Datasheet package: CRCW2512-HP e3 / RR6332M body 6.3 mm × 3.15 mm.
  • Project footprint name: RESC6331X70N, consistent with a 6.3 mm × 3.1 mm chip resistor, nominal height 0.70 mm.
  • Footprint body/fab outline: 6.50 mm × 3.30 mm, slightly larger than nominal body and reasonable as courtyard/fab representation.
  • Footprint pads: pad 1 and pad 2 at ±2.99 mm, size 1.24 mm × 3.32 mm; effective overall Z ≈ 7.22 mm and gap ≈ 4.74 mm.
  • Datasheet recommended reflow pads: Y 1.25 mm, X 3.35 mm, Z 7.50 mm, G 5.00 mm.
  • Result: Pad size is effectively matching datasheet reflow recommendation; overall length/gap are slightly smaller than datasheet nominal reflow recommendation by about 0.28 mm Z and 0.26 mm G, but are close and likely acceptable depending on the footprint generator/library tolerance.
Mismatches / gaps flagged
  1. Project metadata initially lacked a Datasheet URL; I added the official Vishay URL.
  2. Pin descriptions are blank/undefined on the two terminals.
  3. The project properties do not explicitly list the parsed resistance, tolerance, power rating, TCR, manufacturer name, or operating temperature; these are inferable from the MPN and datasheet but should be added if this part is intended as a high-quality library component.
  4. Footprint pad geometry is close to, but not an exact match for, Vishay’s reflow recommendation: project Z ≈ 7.22 mm vs datasheet Z 7.50 mm; project G ≈ 4.74 mm vs datasheet G 5.00 mm.
Overall verdict
The part is fundamentally consistent with the official Vishay CRCW2512-HP e3 datasheet: 2-pin passive resistor symbol and 2512 footprint. The main cleanup items are metadata completeness and optional footprint pad tuning to exactly match Vishay’s recommended reflow land pattern.
  • Source reviewed

  • Project part information observed

  • Key datasheet specs for CRCW2512-HP e3

  • Symbol cross-check

  • Footprint cross-check

  • Mismatches / gaps flagged