Arranged all 74 components into eight readable functional blocks, with local wires, inter-block net labels, and cleaned-up power symbols and label spacing. Verified that all 47 nets, component values, and pin connections are unchanged; no PCB edits were made.
Three clear, non-junction UART crossings remain. Pre-existing electrical-check findings were left untouched; electrical review is the next step before PCB layout.