Initial Requirements and Safety Scope
User request
Start a controller project for a hybrid geyser (water heater) with gas and electric heating, controlled over a LAN from an Android app. The user reports that only a burner and an electric heating rod are installed; no other components are installed.
Current state
- Requirements captured only. No circuit, components, wiring, firmware, app, or PCB has been created or verified.
- Gas and electric heater specifications, water-heater construction, existing safety devices, and local installation requirements are unknown.
Safety direction
Do not directly automate the bare gas burner. Gas operation needs a certified burner-management assembly appropriate to the appliance, including supervised ignition, flame-failure shutoff, and suitable normally closed gas valves. A custom LAN controller should request heat through the approved control interface, not replace combustion safety controls.
Electric heating requires appropriately rated switching, protective earthing, overcurrent and residual-current protection as applicable, and an independent overtemperature cutoff. Water-level/dry-fire protection and pressure/temperature relief requirements depend on the heater construction. These protections must not depend on the app, LAN, or custom controller firmware. Installation and commissioning require qualified gas and electrical professionals.
Simultaneous gas and electric heating is not assumed safe or approved. Leave it disabled unless the appliance design explicitly permits it. Loss of network communication must not defeat local safety protections.
Required inputs before circuit design
- Heater make/model, or photos of the whole heater, burner, electric rod nameplate, plumbing, and any existing valves or safety fittings.
- Electric rod rated voltage and wattage, supply voltage, and installation country.
- Gas type (LPG or natural gas), burner rating if known, and whether any gas valve, ignition unit, or flame sensor exists.
- Whether the heater is a pressurized storage tank, an open tank, or an instantaneous heater; capacity if applicable.
- Whether LAN means wired Ethernet or local Wi-Fi, and whether the user wants selectable gas/electric modes or concurrent operation.
Next work
Resolve the appliance and safety requirements first, choose the certified gas-control interface and electric safety architecture, then develop the supervisory controller and Android/LAN interface. No component selections or implementation claims have been made.
Session limitation
Execution stopped because the user's ACUs ran out. Resume from these requirements; the electronics design remains empty.