ChipSHOUTER Rebuild


Created 2 project docs

Reconstruction Uncertainty Register

View Document

Reconstruction Uncertainty Register Scope and Rule
This project reconstructs the CW520 ChipSHOUTER Rev. 07 schematic only from the supplied 8-page schematic PDF and 78-page user manual. No safety-critical value, part number, pin connection, isolation boundary, calibration constant, or construction detail may be inferred when it is not legible or explicitly supported.
Safety Boundary
The reference design stores up to approximately 625 mJ in a nominal 5 uF capacitor bank at 500 V and drives a high-current pulse into an external inductive probe. The reconstructed schematic is documentation and engineering-reference work only. It is not approved for fabrication, energization, or human use until the missing items below are resolved and a qualified high-voltage engineer reviews the ...

Project Specification

View Document

Project Specification Project Overview
  • Status: Draft reconstruction
  • Recreate the CW520 ChipSHOUTER Rev. 07 electrical schematic as closely as the supplied PDFs permit.
  • Preserve original reference designators, named nets, component values, MPNs, and functional partitioning where legible.
  • Do not guess safety-critical information.
Intended Use
Engineering study and controlled schematic reconstruction for security-research instrumentation. The first phase is schematic capture only; it is not a fabrication-ready or energized prototype.
What the Device Should Do
The reference device charges a high-voltage capacitor bank from a 19 V input, then applies controlled short pulses to an external inductive injection probe. A microcontroller supervises charging, triggering, ...
The uncertainty register is now saved, including every known missing semiconductor, rating, layout, firmware, calibration, probe, and safety item. I’m now capturing the evidenced schematic blocks while leaving unsupported high-voltage details unresolved.
Thought for 2 mins 17 sec
Thought for 6 sec
Awaiting 1 background task
No project changes were made this turn. I wasn’t able to inspect the FaultyCat repository or compare its hardware against the ChipSHOUTER Rev. 07 PDFs, so the reconstruction remains unchanged and the proposed adaptation has not been evaluated.
Still required:
  • Inspect the repository’s schematic, PCB, BOM, and licensing.
  • Compare FaultyCat’s charging, energy storage, pulse-switch, trigger, discharge, sensing, and safety architecture with Rev. 07.
  • Record all differences and preserve unresolved high-voltage values as explicit unknowns.
  • Adapt only evidence-backed circuitry; do not infer safety-critical ratings or isolation geometry.
  • Independently verify the resulting schematic before layout.
Execution stopped because your ACUs ran out.

Waiting for input

No schematic yet

Talk to Flux to get started.

Reconstruction Uncertainty Register
Scope and Rule
This project reconstructs the CW520 ChipSHOUTER Rev. 07 schematic only from the supplied 8-page schematic PDF and 78-page user manual. No safety-critical value, part number, pin connection, isolation boundary, calibration constant, or construction detail may be inferred when it is not legible or explicitly supported.
Safety Boundary
The reference design stores up to approximately 625 mJ in a nominal 5 uF capacitor bank at 500 V and drives a high-current pulse into an external inductive probe. The reconstructed schematic is documentation and engineering-reference work only. It is not approved for fabrication, energization, or human use until the missing items below are resolved and a qualified high-voltage engineer reviews the design, PCB geometry, enclosure, interlocks, firmware, and test plan.
Missing or Uncertain Active Components

Table


RefKnown informationMissing or uncertain informationStatus / rule
Q4Located in the high-voltage pulse-switch sectionExact MPN, package, pin mapping, pulsed SOA, avalanche behavior, gate charge, VDS/VGS ratingsBLOCKED — do not substitute or wire by assumption
Q11Located in the high-voltage pulse-switch sectionExact MPN, package, pin mapping, pulsed SOA, avalanche behavior, gate charge, VDS/VGS ratingsBLOCKED — do not substitute or wire by assumption
Q6Input/reverse-protection or power-switching areaExact MPN, package, polarity, pin mapping, electrical ratingsBLOCKED — preserve as unresolved
D2, D3Marked 650 V / 20 A clamp or catch devicesExact MPN, technology, package, recovery behavior, pulse ratingBLOCKED for fabrication
Several mechanical/coax partsManufacturer numbers are visible in placesExact variants, footprint revisions, and mating details are incompleteReconstruct only where a verified library match exists
Passive and Population Uncertainty
  • The PDF does not provide a complete BOM with tolerance, power rating, voltage rating, dielectric, pulse rating, package, approved alternates, or DNP/DNM state for every passive.
  • High-voltage divider, bleeder, discharge, gate, shunt, and snubber parts require exact package and pulse/voltage ratings; nominal resistance alone is insufficient.
  • R34 is shown as 10 ohm with the note that tuning is part of the design. Its final production value and tuning procedure are unknown.
  • Capacitor bank C10-C14 is shown as five 1 uF, 630 V, X7T capacitors, but exact MPN, capacitance tolerance, DC-bias behavior, pulse-current rating, and physical layout are absent.
  • Transformer T1 is identified as DA2033-AL, but winding implementation, creepage implementation, and PCB-field behavior still depend on the missing layout and production data.
Connectivity and Net Uncertainty
  • Some fine connections, pin numbers, and net labels in dense high-voltage pages may be unreadable at the supplied PDF resolution.
  • Separate domains are shown or implied: GND, PGND, HVGND, OutputGND, VCC, VCC_DIRTY, +16V, HVSTORAGE, HVPOWER, HVSWITCHED, and HVCONNOUT. Their PCB joining method, net-tie implementation, copper geometry, and chassis relationship are not fully defined.
  • The SMA shell is specifically not equivalent to chassis ground according to the manual; the exact grounding implementation must not be guessed.
  • The fast external-trigger path crosses logic and pulse-switch sections. Propagation-delay matching and polarity behavior require confirmation from the original design files or measurement.
Missing PCB and Mechanical Definition
  • No Altium PCB source, Gerbers, ODB++, drill data, stackup, copper weight, controlled-impedance data, assembly drawings, or placement files are supplied.
  • High-voltage creepage and clearance, slots/cutouts, conformal coating requirements, keepouts, field-control geometry, current-loop geometry, and thermal copper cannot be recovered from the schematic.
  • Enclosure machining, interlock actuation geometry, exposed-metal bonding, cooling-port protection, and coax connector mounting are incomplete.
  • Probe/tip ferrite material, turns, wire type, insulation system, winding direction details, potting, conductor spacing, and qualification tests are missing.
Missing Firmware and Calibration
  • ATXMEGA128A4U firmware source and production binary are not supplied.
  • Bootloader/update process, device-specific identity/signing behavior, fuse configuration, clock configuration, EEPROM defaults, and factory programming steps are missing.
  • AD5259 digital-pot calibration mapping between requested voltage and charger feedback is missing.
  • HV voltage/current monitor gain, offset, bandwidth, and production calibration are incomplete.
  • Temperature thresholds, timeout limits, probe-open detection thresholds, fault latching, safe-trigger behavior, EEPROM CRC behavior, and interlock state machine must be recovered or independently re-engineered.
  • Pattern timing is described operationally, but timer/peripheral implementation and delay calibration are not supplied.
Missing Production and Safety Evidence
  • No dielectric-withstand, insulation-resistance, leakage, abnormal-operation, thermal, EMC, ESD, or enclosure-access test reports are supplied.
  • No production test limits, calibration fixtures, golden-unit waveforms, probe characterization, component derating report, or failure-mode analysis is supplied.
  • Regulatory status and applicable laboratory evidence are unknown.
Reconstruction Policy
  1. Add and connect parts only when the reference designator, part/value, pins, and connections are legible or independently verified.
  2. Use explicit unresolved notes/placeholders only when they cannot create a misleading electrically complete design.
  3. Do not select substitute pulse-switch semiconductors or high-voltage passives without a separate engineering design and validation phase.
  4. Do not claim the reconstruction is buildable, safe, calibrated, or equivalent to the commercial unit.
  5. Maintain this register as the authoritative list of blockers.
  • Scope and Rule

  • Safety Boundary

  • Missing or Uncertain Active Components

  • Passive and Population Uncertainty

  • Connectivity and Net Uncertainty

  • Missing PCB and Mechanical Definition

  • Missing Firmware and Calibration

  • Missing Production and Safety Evidence

  • Reconstruction Policy