Architecture recommendation, not a released circuit or approved power installation. No components, nets, PCB layout, or firmware exist yet. Research has been recovered and reconciled; the clip-on optical assembly, electrical protection, exact currents, thermal construction, and manufacturing process remain gates. See Design Brief for confirmed requirements and Architecture Research Progress for the full analytical power assumptions.
Recommended product construction
One 1000 mm rigid lighting assembly, board width at most 30 mm, ten RGBW packages and five paired zones. Aluminum extrusion ...
I recommend insulated power conductors inside the aluminum backing, with shorter LED PCBs forming each rigid 1000 mm panel, rather than carrying the fourteen-panel chain current through narrow PCB traces.
Do you approve that construction for prototype development?
Architecture recommendation, not a released circuit or approved power installation. No components, nets, PCB layout, or firmware exist yet. Research has been recovered and reconciled; the clip-on optical assembly, electrical protection, exact currents, thermal construction, and manufacturing process remain gates. See Design Brief for confirmed requirements and Architecture Research Progress for the full analytical power assumptions.
Recommended product construction
One 1000 mm rigid lighting assembly, board width at most 30 mm, ten RGBW packages and five paired zones. Aluminum extrusion provides structure and heat rejection. Evaluate short LED thermal substrates and a control/driver PCB rather than assuming an ordinary one-metre FR4 board is an adequate LED heat path. PCB segmentation is a proposal, not an approved change to the user's one-metre product.
Use insulated copper bus conductors integrated along the backing for +24 V and return, with protected local taps. Supply injection remains at the two ends only; integrated conductors are not additional supply injection points. This differs from carrying all chain current in narrow PCB traces and needs approval before implementation.
Emitter and optics
The best identified neutral-white emitter candidate is Cree XMLDCL-00-0000-00C4AAAE5. Its documented white range is 3700–4300 K, not a guarantee of exact 4000 K. Treat this as a proposed nominal-neutral-white bin; procurement must confirm acceptable tolerance, color quality, and stock. Do not substitute the different-CCT library variant found in the initial search. Operate at no more than 3 W electrical total per package; a higher component maximum rating does not increase the product power budget.
LEDiL CA18093_LEILA-Y-WW explicitly lists XM-L RGBW XMLDCL HD at 60° FWHM and 80° FWTM, simulated. Its 21.6 mm diameter and 14.8 mm height fit the width envelope, but do not establish the total assembled product thickness. This verified optical pairing uses tape/locating pins, not the requested PCB solder-clip holder. The earlier generic approximately 55° family description must not replace the emitter-specific 60° chart.
Clip-on requirement remains open: CP19442_LEILA-Y-SC2-WW shares the C18086 lens and uses C19437 holder/C18696_SOLDER-CLIP-2, with a documented 21.6 mm × 14.8 mm envelope and 20.8 ±0.2 mm post-solder clip reference spacing. Its compatibility chart does not establish XMLDCL assembled fit, and its drawing calls for product-specific 3D-model verification. Shared lens geometry is not proof of holder clearance, focal height, or installed RGBW beam. Retain clip-on mounting unless the user explicitly accepts the verified tape/pin alternative. Obtain manufacturer confirmation/3D fit check and a physical sample before releasing lens mounting geometry. A wet/coated/covered assembly needs new beam and color-mixing tests.
Paired-zone LED drivers
Baseline: twenty switching constant-current channels per panel, four per two-package zone. Connect the corresponding color dies of each pair in series only after the exact selected emitter datasheet and symbol confirm separately accessible anode/cathode terminals for all dies. Common-anode/cathode packages are not drop-in substitutes for this architecture. A common-terminal substitution would require redesign and possibly forty regulated channels grouped into twenty controls.
Recommended driver candidate: TPS92515DGQR, twenty per board. Documented operating capability is 5.5–42 V and up to 2 A average LED current; these are component capabilities, not selected operating currents. Its documented standard PWM range includes 100 Hz–2 kHz. An illustrative approximately 200 ns practical pulse budget/500:1 dimming example at 10 kHz is not a guaranteed dimming ratio for this design. This is a better-qualified lighting baseline than the lower-cost AL8860 candidate, whose prior research did not establish acceptable low-end dimming at the intended frequency. Twenty switching stages carry significant BOM, magnetics, placement, and EMI cost; pricing is unverified.
Select color currents from actual maximum forward voltages, current-sense tolerance, temperature, and allowed simultaneous die operation. Hardware limits must ensure, for each package, sum(Vf_color,max × I_color,max) ≤ 3 W at simultaneous full scale. The limit applies per package, not per two-LED pair. Sense resistors, inductors, switching frequency, ripple, diode ratings, losses, and thermal margins are not selected. Firmware can reduce output but must not be the only protection against exceeding the electrical envelope. Include temperature monitoring and thermal derating after the thermal path is established.
Controller and dimming
Retain STM32G0B1RBT6 as the MCU candidate; pin assignment, clock, programming/debug access, UART error handling, watchdog, memory and power budgets remain schematic tasks. Its twenty hardware PWM pins are not assumed available.
Use two PCA9685PW,118 devices: they provide sixteen independently programmed 12-bit PWM outputs each and an internal-clock PWM range of approximately 24–1526 Hz. Allocate outputs 0–15 on the first device and 0–3 on the second, with distinct I²C addresses. Start qualification around 1–1.5 kHz. Each IC shares a frequency among its outputs; inter-IC frequency/phase synchronization is not established by this recommendation.
Use non-inverted push-pull operation, OUTDRV=1 and INVRT=0. Hardware OE pulled high with OUTNE=00 forces outputs low when configured accordingly. Include local driver-PWM pulldowns so power-up/high-impedance states cannot turn LEDs on. Initialize zero duty and known output mode before enabling; prove the exact reset/default states and power sequencing at schematic review. The documented PCA output-high minimum at 3 V is 2.3 V versus TPS PWM rising threshold no greater than 1.05 V, giving static logic margin; loading, edges and supply tolerances still need checks.
Keep twenty 8-bit DMX control values. Twelve-bit electrical PWM does not guarantee twelve-bit optical resolution; qualify the shortest useful optical pulse, especially with gamma correction. Do not add low-frequency temporal dithering to hide an unqualified pulse floor. This is not a flicker-free or camera-safe claim: test photodiode/current waveforms and representative camera exposure/frame-rate combinations. Higher-frequency camera requirements would reopen the PWM-generation architecture.
Required fail-off enable path: PWM expanders may retain a previous duty value when the MCU stalls. Gate their common OE with reset/brownout and an independent watchdog timeout so a stuck MCU LED-enable request cannot override hardware disable. A pull-up alone while a stalled GPIO remains driven low is insufficient. Select the actual supervisor/watchdog and prove its startup, timeout and reset wiring during prototype schematic capture; enable may only return after zero-duty initialization. Test lockup, I²C failure, brownout and retained-PWM states. Do not treat a software blackout command as the sole fault response.
Automatic DMX allocation
Recommend consume twenty slots, regenerate the remainder. Each panel receives standard DMX, uses its first twenty null-start-code slots, and emits a newly generated stream containing the remaining slots. Outputs must be labelled processed DATA OUT, not transparent DMX THRU. Panel n uses original slots 20(n−1)+1 through 20n; panel fourteen uses 261–280. No DIP settings or discovery master are required for this physical-order behavior.
This is address allocation by stream transformation, not RDM enumeration. Baseline does not support RDM or alternate start codes. Other fixture types connected downstream would see shifted channels. Powered-off or failed panels interrupt the chain; bypass is not included, and a bypass would change downstream mapping unless deliberately addressed.
Proposed implementation uses independent RX/TX UART paths, a FIFO, validated BREAK/MAB/start code, and streaming rather than a full-frame delay per panel. Consume local twenty slots; generate a fresh output header; forward the remaining slots with adequate FIFO headroom and paced transmission. Handle legal minimum input headers, input/output baud mismatch, gaps, short packets and minimum output frame spacing. Do not assume equal nominal UART rates prevent FIFO underrun/overrun.
Provisional standards extraction, not yet validated with inline citation handles: ANSI E1.11-2024, §8.2/Table 5 and §8.7/§8.10–8.11/Tables 6–7: 250 kbit/s, 8N2, 44 µs nominal slot; transmitter BREAK at least 92 µs, MAB at least 12 µs, break-to-break at least 1204 µs; no fixed minimum data-slot count. Treat these extracted timing values as provisional until checked against the current standard during firmware implementation.
The earlier ideal contiguous-slot model gives approximately 296 µs added delay for a forwarded original slot per link and about 3.85 ms across thirteen forwarding hops. These are estimates with assumed headers and no scheduling margin, not implemented or measured guarantees. Different legal headers, baud mismatch, firmware buffering and gaps change the result. Do not advertise zero latency or use these values as acceptance limits.
Policies to implement and test: startup off; atomically latch a complete twenty-slot zone block; explicitly handle incomplete packets without stale trailing-channel reuse; define signal-loss blackout/hold timeout; suppress downstream packets when no slots remain or generate a deliberately compliant defined alternative; discard alternate start codes; recover from framing errors, new BREAK, FIFO overflow and hot-plug. Terminate each point-to-point segment at its receiver. Define signal common, shield/chassis, galvanic isolation and surge protection before connector release. Transceiver ESD ratings alone do not establish sheltered-outdoor immunity.
Prototype protocol defaults selected: latch all twenty local slots atomically only after a complete valid null-start-code block. Incomplete local blocks retain the last complete state without refreshing its freshness timer; after one second without a complete valid local block, switch all local outputs off. A panel may still forward valid remaining slots while locally blacked out. Suppress output when no slots remain. Discard unsupported start codes; abort/resynchronize malformed frames and FIFO faults. A streaming output cannot retract bytes already emitted when a late input fault occurs; the downstream stale-state timeout remains necessary. Validate these policies and compliant short-frame spacing against E1.11 before firmware release. Watchdog failure disables output independently of this one-second data-loss policy.
THVD1450DR remains a receiver/transmitter candidate. A library package-field discrepancy was reported: inspect the actual eight-terminal footprint before use. Choose isolation/protection and budget their load before selecting the logic supply; LMR36503RFRPER is only a control-buck candidate, not an approved total power solution.
Dual-end power and protection
Ten packages give at most 30 W LED electrical load per panel; fourteen panels at most 420 W before conversion/control losses. The preliminary scenario assumes 90% LED-driver efficiency and 0.5 W input-side controls per panel: 33.83 W/panel, 473.67 W/chain, 19.74 A at 24 V, before bus/feed losses. The controls assumption must be replaced with a real budget including two PWM expanders, MCU, transceivers, isolation and protection. At 85–95% driver efficiency the scenario is 501.12–449.11 W. A 600 W PSU is a candidate class only, subject to actual load, ambient derating, startup and reserve.
Recommend investigating 4–6 mm² insulated copper conductors per polarity integrated along the extrusion. This is a voltage-drop direction, not an ampacity approval. With 4 mm² rails over 14 m, hot-copper model at 80°C, and ideal equal feeds, calculated rail-only centre drop is 0.368 V. A worked example including 10 mΩ loop resistance per joint and two 5 m one-way 6 mm² feed cables gives about 1.014 V nominal drop, or a conservative constant-power bound of 1.061 V. Real cable lengths, joints, corrosion and feed imbalance remain unknown; the complete model and sources are in Architecture Research Progress.
Use one properly specified supply with two separately protected feeds, not independent supplies paralleled without a sharing design. Protect against reverse energization of a damaged feed through the opposite end; source fuses alone may not do so. Analyze faults receiving current from both ends, protect local taps, coordinate PSU current limiting with fuse clearing, and disconnect both feeds together. Do not use the aluminum backing or DMX shield as return.
Loss of one feed approximately doubles surviving-end current and quadruples ideal rail heating/drop before constant-power escalation. Either rate the full installation for this condition or implement a proven feed-fault interlock/dimming mechanism. Local voltage sensing alone is not proof that every single-feed failure is detectable. Protection and detection architecture remains open; no fuse/connector rating is approved.
Thermal, mechanical and environmental gates
The conservative scenario treats 33.83 W per panel as heat before allocated bus loss. An illustrative 40°C ambient/70°C extrusion target implies extrusion-to-air thermal resistance no greater than approximately 0.89 K/W per metre, before local gradients. This is not a confirmed ambient requirement or a selected heatsink. A bare 30 mm flat plate is not assumed adequate. Validate junction-to-solder-to-substrate-to-TIM-to-extrusion resistance; ordinary FR4 backed with aluminum can retain a severe local thermal bottleneck.
Source leads for fabrication, construction-specific capability not approved: JLCPCB dimensions and assembly capabilities. Prior research reported selected one-metre FR4 fabrication possibilities but shorter standard aluminum-core/assembly limits. Confirm the exact substrate, copper, panel aspect ratio and assembly route with the chosen fabricator before choosing continuous versus segmented PCBs. Do not infer that FR4 size capability establishes one-metre MCPCB or heavy-copper capability.
For sheltered outdoor use, plan protected/glanded connections, strain relief, moisture management, and selective coating away from optical surfaces, clip interfaces and thermal contacts. Do not claim an IP rating. Assess condensation, corrosion, cover/lens effects, thermal expansion and maintenance. Maximum ambient, solar exposure and mounting orientation remain inputs to obtain before full-power qualification.
Next build and release criteria
Confirm clip-on holder fit/beam, acceptable neutral-white bin and emitter availability; otherwise ask for explicit optical-mounting substitution approval.
Approve integrated power-bus construction and any internal PCB segmentation while retaining the one-metre rigid assembly.
Capture a two-emitter/four-driver optical/thermal prototype and a two-node consume20 DMX prototype. Exact LED currents, protection, isolation, startup-off behavior and supply budgets must be resolved in those schematics.
Test full-white and individual-color electrical power, minimum dimming pulse, camera artifacts, optical mixing/beam, temperatures and moisture effects. Test addressing, short/malformed packets, signal loss, power sequencing and chain fault behavior.
Only then replicate to the full five-zone panel and validate a fourteen-panel bus under hot copper, unequal feeds and single-feed faults. No manufacturing or full-power operating approval is implied by this architecture record.
Architecture review disposition
An independent bounded consistency review found no definite architecture-level electrical contradiction and judged this suitable for conditional presentation, not unrestricted schematic or manufacturing release. Optical clip fit, CCT-tolerance acceptance, independently terminated die evidence, bus/segmentation approval and full-chain fault protection remain gates. The review's retained-PWM/MCU-lockup concern is addressed by the required independent fail-off enable path above; it is a schematic requirement, not implemented hardware. DMX edge-policy defaults are now explicit. Numerical rating margins remain unverified wherever exact parts, currents, transients, thermal geometry or wiring are unselected. No ERC/DRC or hardware test has been performed.