Placed all 62 components on the Top side of the unchanged 90 × 50 mm board. Independent review confirmed no body overlaps, out-of-bounds parts, edge-placement faults, or critical buck-stage findings.
Open items
8 U2/U3 self-keepout false positives from each module intersecting its own antenna void.
12 decoupling proximity warnings and 116 expected airwires remain.
Completed: the subsequently authorized 3V3_PG: U4:PG → J4:10 extension, in exactly one mutate_layout_routes call with terminals [U4:PG, R3:P2, J4:10], width 0.20 mm. Result: one pair connected, zero failures, 68.210 mm of new Top-layer routing; no vias. Read-back confirms 13 added ordinary Top trace segments, retaining the existing four PG segments to R3.
Post-route routing state: 96 global airwires, zero buck-local airwires including the J4 PG extension, and zero redundant traces. Relevant overlap, invalid-layer, dangling/floating/redundant copper, under-connected via, keepout and protected-intrusion checks returned no findings; the mutation reported only resolution of one airwire, no introduced issues. Placement, existing copper and rules were preserved; no neckdowns or full-board autorouting were used. Downstream 3V3 and 5V_RAW extensions were unattempted as instructed. The prior explicit-GND limitation and loop-area warnings are not resolved by this focused pass. Historical counts and the earlier exclusion of J4 below describe the initial batch, not the current PG completion state.
Scope and outcome
Fixed-placement, buck-only targeted routing performed on 2026-09-14. Local members: U4 (LMR33630BDDAR), L1, F1, D1, C1–C8, R1–R3; J1:A/C included only as the essential input power/return interface. No MCU, UWB, LED, unrelated header signal or test-point connections were requested from the router.
Batch outcome: partial against the strict explicit-traces criterion. All local non-ground islands are connected, with zero remaining local buck airwires. Local GND terminals already share the existing GND fill; the required targeted routing tool returned already-connected and created no explicit ground-return traces. Thus do not represent this result as a new explicit-trace implementation of every ground return, or as completion of the whole PCB.
Table
Assigned item
Status
Evidence / limitation
Inspect connectivity, pad geometry, stackup/rules and existing copper
Completed
Live schematic, netlist, layout SVG, scene-tree and rules inspected
Pre-routing board/redundant checks
Completed
Board valid; no feasibility anomalies; 116 board airwires, zero redundant traces
Local input power chain
Completed
J1:A–F1:1 and all six 5V_PROTECTED terminals connected
Switch stage
Completed
U4:SW, L1:2, C4:P2 connected on Top, 0.60 mm
Output bank and local sense/pull-up supply
Completed
L1:1, C5–C8:P1, R1:P1, R3:P1 share one routed island
Explicit local PGND/GND return routing
Failed to add explicit traces
Existing fill already connects all selected returns; mutate_layout_routes has no force-route/ignore-fill argument. No fill/rule/placement change made
Bootstrap and VCC bias
Completed
U4:BOOT–C4:P1 and U4:VCC–C3:P1, Top 0.25 mm
Feedback and local PG/control
Completed
U4:FB–R1:P2–R2:P1; U4:PG–R3:P2. EN was included in input call because it is the same net as VIN
Cleanup and final checks
Completed
One newly redundant BUCK_FB segment deleted; final zero redundant traces; requested copper checks returned no findings
Unrelated board routing
Unattempted, intentionally
97 board-wide airwires remain outside this local batch
No neckdown generation was called, no neckdown nodes were created or used, no full-board autorouting was called, no components were moved/rotated/relayered/repacked, and no clearance or manufacturing rules were changed. Final component bounds report still lists all 62 components on Top. The editor-focus request was attempted but returned The requester frontend session was not found.
Live connectivity used
5V_RAW: J1:A, F1:1; TP1:P1 deliberately excluded as a nonessential test-point branch.
F1's two pads have the same public name ~, so exact pad UIDs were used: pin 1 = ece994f3-c61e-4b30-bf2e-143d1f73f48c__a52699de-9d4f-4857-bfbc-eeca456d9992; pin 2 = ece994f3-c61e-4b30-bf2e-143d1f73f48c__dbd167ba-115f-4e87-9806-c84f6de9af68.
Geometry and rules inspected
Board: 90 × 50 mm, existing rounded rectangle. Stackup: JLCPCB HDI 4L, 1.53 mm total; Top 35 µm copper, Mid-Layer 1 power plane 18 µm, Mid-Layer 2 signal 18 µm, Bottom 35 µm. Applied target reports High Density 4 Layer v3, BoardHaus Simple New v1 capability, and custom JLCPCB HDI 4L v1 stackup.
Manufacturing minimum trace width and copper spacing: 0.0762 mm. Existing scoped nominal widths were 5 V 0.80 mm, SW 1.00 mm, 3V3 0.60 mm, BOOT/VCC 0.25 mm, FB 0.15 mm. Explicit call widths override routing width only; none of these rules were edited.
Key pad centers, in world mm (rounded):
Table
Component
Pin / center(s)
U4
VIN (-14.72,13.64); EN (-14.72,12.37); PGND (-14.72,14.91); EP (-12,13); SW (-9.28,14.91); BOOT (-9.28,13.64); VCC (-9.28,12.37); FB (-9.28,11.10); PG (-14.72,11.10)
L1
1/output (-13,20); 2/SW (-7,20)
F1
1/raw (-20.525,8.5); 2/protected (-23.475,8.5)
D1
1/GND (-17.45,10.9); 2/protected (-20.55,10.9)
C1
P1 (-19,12.75); P2 (-19,14.65)
C2
P1 (-17.2,12.925); P2 (-17.2,14.475)
C3
P1 (-7.275,11.5); P2 (-5.725,11.5)
C4
P1 (-6.8,13.525); P2 (-6.8,15.075)
C5–C8
x = -15.4,-17.4,-19.4,-21.4; P1 y=18.45, P2 y=16.55
R1
P1 (-10.825,9); P2 (-9.175,9)
R2
P1 (-13.825,9); P2 (-12.175,9)
R3
P1 (-15.175,9); P2 (-16.825,9)
J1
A (-27.5,10.975); C (-32.3,13.975)
U4 lead pads are 0.60 mm across their narrow axis, so VIN and SW routes use a uniform 0.60 mm rather than the wider inherited widths that would need narrow escapes. C1/C5–C8 pads have a 1.00 mm minimum dimension, resistor pads 0.80 mm, and C2–C4 pads 0.90 mm. No route was requested wider than its limiting terminal geometry. Input 0.80 mm and output-bank 0.80 mm are consistent with their larger pads. The 0.25 mm output sense/pull-up branch carries only the divider/pull-up currents, not the board load.
Current metadata is not a thermal signoff: U4 role and 3V3 current state an estimated 0.402 A board peak, while rail metadata also carries 2 A input maximum, 1.5 A output maximum, and 4 A SW maximum. Full sustained operation at these maximum metadata values was not thermally validated; particularly the uniform pad-limited 0.60 mm SW route must not be advertised as a validated continuous 4 A path.
Itemized mutation log
Each numbered route operation below was one mutate_layout_routes call on one net. Routing state was read after every call that persisted routes. Lengths are the tool-reported centerline lengths, not pad-edge lengths.
5V_RAW, terminals J1:A, F1:1; 0.80 mm. Connected J1:A–F1:1, 11.089 mm, Top. No failures. Board airwires 116 → 115.
5V_PROTECTED, terminals U4:VIN, C2:P1, C1:P1, D1:2, F1:2, U4:EN; 0.60 mm. Connected VIN–EN 1.200 mm; C2–C1 1.976 mm; C1–D1 2.492 mm; C2–EN 2.649 mm; D1–F1 3.963 mm, all Top. No failures. Airwires 115 → 110. The deterministic tool chose the EN pad as the input-cap branch junction; it does not expose ordered waypoint control.
BUCK_SW, terminals U4:SW, L1:2, C4:P2; 0.60 mm. Connected U4:SW–C4:P2 2.548 mm, and L1:2–C4:P2 5.008 mm, Top only, no vias. Airwires 110 → 108. Compact orthogonal/45° route beside L1; no long board detour.
3V3, terminals L1:1, C5–C8:P1, R1:P1, R3:P1; 0.80 mm. Connected C5–C6 2.000 mm, C6–C7 2.000 mm, C7–C8 2.000 mm, L1–C5 3.042 mm, R1–R3 6.821 mm, all Top. C5–R3 failed once with blocked-no-path. Airwires 108 → 103. Useful copper retained; no placement changes.
GND, all 12 local terminals listed above; requested 0.60 mm. Result already-connected, one island, no routes and no vias added; airwires 103. Existing GND fill and stitching provide connectivity. No pointless retry was made.
BUCK_BOOT, U4:BOOT, C4:P1; 0.25 mm. Connected 2.533 mm, Top. Airwires 103 → 102.
BUCK_VCC, U4:VCC, C3:P1; 0.25 mm. Connected 2.365 mm, Top. Airwires 102 → 101.
3V3 sense/pull-up supply retry, same seven local terminals as call 4; 0.25 mm, existing bank copper retained. Connected the two existing islands from near (-15.350,18.450) to (-15.175,9.000), 9.581 mm, using Top–Bottom–Top and two through-hole smart vias. No failures. Airwires 101 → 100. Bottom section is 8.0 mm long at world x=-15.35, y=17.575 to 9.575; top endpoint sections connect it to bank and pull-up supply. Scene-tree Bottom rule coordinates have the platform's mirrored X representation. This narrower branch is a low-current sense supply, not a neckdown escape or a reduction of the 0.80 mm bank rail.
BUCK_FB, U4:FB, R1:P2, R2:P1; 0.15 mm. Connected FB–R1 2.131 mm and R1–R2 5.271 mm, Top. Airwires 100 → 98. FB runs south of U4, with divider interconnect around y=9.75 mm, well away from SW copper at y≥14.91 mm. Routing state identified one redundant short BUCK_FB segment.
3V3_PG, U4:PG, R3:P2; 0.20 mm. Connected 3.089 mm, Top. Airwires 98 → 97. No failures; J4 branch untouched.
Cleanup, mutate_layout_nodes delete_traces: removed only Trace 0fc0, UID 0fc0766e-c4f5-4b79-89e5-68c4219fa065, confirmed on BUCK_FB. Redundant-trace warning resolved. Airwires remained 97.
Nine route calls persisted copper; one GND call was a no-op. One connection failed once and succeeded on its only retry. Final scene-tree contains 53 ordinary trace segments and two new 3V3 smart vias; no custom/neckdown traces. The two new vias use the existing stackup through-hole configuration (nominal 0.45 mm pad / 0.20 mm drill). Existing generic via rules separately specify larger minima; the final board check reported no conflict, but manufacturing release should reconcile the applied stackup-via configuration and profile minima rather than silently alter either.
Verification and residuals
Initial and final run_auto_route_check: Board valid: yes; no routing feasibility issues detected.
Final routing state: 97 global airwires; zero redundant traces. The 19-airwire reduction is entirely from selected local buck connections.
Zero missing local buck connections between the selected terminals. The global 3V3 airwire display uses a spanning graph across remote loads, so it is not a direct display of every island pair; successful two-island completion in call 8 provides the local output/sense connectivity evidence.
Deliberately remaining shared-net extensions include TP1:P1 to 5V_RAW, U4:PG to J4:10, and remote 3V3 loads. These are not unfinished local-stage routes.
Final requested reviews returned no matching findings for overlapping copper/traces/fills, invalid layer, floating/dangling/redundant copper, under-connected vias, switching power stage, pad-access clearance, keepout, protected intrusions and stackup validation. These tools do not emit an individual positive-success record for each zero-finding review; this is a no-reported-findings result, not a manufacturing or electrical-performance signoff.
Full DRC error/warning pagination reported 97 airwire errors and 15 warnings: 14 decoupling-loop-area warnings and one existing VREF+ component override. Local loop-area warnings involve C1, C5, C6, C7 and C8. No blocking copper/routing error was reported.
The local loop warnings cannot be resolved by asserting connectivity alone. Their suggested remedy is capacitor placement/orientation adjustment; all such changes remain unattempted because placement is fixed.
Approval/tool limitation: if explicit local GND-return traces are mandatory even over already-connected fill, the lead must arrange an explicit-geometry routing method or obtain approval for a scoped fill/connectivity change. This batch did not disable the ground fill or modify rules to force unnecessary routing. For loop-area improvement, specific placement changes require user approval first.
All schematic components, values and logical net assignments were preserved. This audit reports completion of the assigned routing attempts, not completion of the overall design or validation at maximum converter current.