Routing Platform Support Handoff
Prepared 2026-10-25 for ESP32 LoRaWAN CAN Battery Monitor. Draft evidence handoff only; no support ticket submitted.
Triage summary

Table


IssueDemonstrated/reported observationSuspected cause, not establishedImpact
USB paired endpointsRepeated J2 DP1/DN2 and U13 S1/S2 rejection/warnings survived duplicate-contact bridging and protected breakout; two opens per USB_DP/DN remained in the saved re-layout reportPaired-endpoint representation/escape handling, especially nonadjacent mux terminals; not proof of a defective footprint or a physically impossible routeEnd-to-end USB routing and acceptance blocked
Layer constraintsReport states targeted routing does not honor Forbidden Layers; whole-inner-layer call-local keepouts also block ordinary through-via transitionsUnsupported constraint semantics/API mismatch rather than proven general routing-engine defectCannot safely express the desired combination of outer-layer signal tracks and ordinary through-vias using that workaround
PROBE_VDD orphanZero schematic membership, J6:1 and D8:3 NC, yet a PCB airwire requests their connection; prior net-removal attempt failedStale PCB association/cache or synchronization defect; storage-layer cause unknownOne spurious open; unsafe if mistaken for a legitimate routing target
Error means wrong/unresolved; Warning means possibly wrong; Info means noteworthy. Historical USB feasibility findings are warnings, not proof of a copper short. These three issues do not explain or waive the board's other real opens or power/thermal/manufacturing blockers.
1. USB rejection after real breakout corrections
Persisted facts. Prior transcript review says J2 duplicate data contacts were already bridged and the remaining gaps extended toward D12 and U13. At the 110 × 100 mm re-layout, J2 was moved to (50.42,33) mm, 90°, D12 to (43.8,31.5) mm, 90°, and a protected local breakout was regenerated: 12 segments, no local breakout vias, 0.215 mm width / 0.127 mm gap, 1.3 mm stubs and 5 mm runway. Nominal calculated 90 Ω geometry is not end-to-end impedance or USB compliance proof; other USB routing contains vias. Pair metadata was retained.
The saved report records four paired-endpoint feasibility warnings at both checks surrounding the R14 correction: two D12 representations, J2 DP1/DN2, and U13 S1/S2. Six protected USB cleanup candidates remained unchanged and were intentionally retained. Earlier targeted recovery also failed according to the persisted transcript; individual request payloads and formal error logs were not recovered. Descriptions such as “USB endpoint rejection” are narrative evidence, not invented machine error codes.
Expected: duplicate contacts already connected by valid copper should be recognized, and supported breakout/paired-route handling should either route the continuation or return an actionable endpoint/geometry diagnosis without requiring removal of correct pair metadata. Actual: repeated endpoint rejection/warnings and incomplete channel after physical correction. A representation bug is suspected, not confirmed.
Minimal supported investigation/reproduction, in a support-owned snapshot only:
  1. Inspect #f383759d or #c6444c9e, retaining pair metadata, duplicate bridges, protected breakout and reservations.
  2. Inspect USB_DP membership J2:DP1/DP2, D12:1/6, U13:S1 and USB_DN membership J2:DN1/DN2, D12:3/4, U13:S2; compare actual pad connectivity to endpoint grouping.
  3. Retrieve the existing full-router job below and before/after feasibility records; compare the same J2/U13 endpoint diagnostics despite the new breakout. No fresh retry is needed to establish the reported persistence. Exact targeted-call reproduction requires archived payload retrieval.
Safe request: diagnose paired-endpoint interpretation and provide a supported local endpoint/escape correction or validated platform fix. Do not change schematic membership, swap pins, strip pair metadata, delete protected copper, or reset campaign protections merely to suppress the message.
2. Forbidden Layers versus through-via keepouts
Persisted facts. The full-routing run used Top 0° / Bottom 90° with persistent Forbidden Layers = Mid-Layer 1, Mid-Layer 2. The report explicitly distinguishes targeted routing, which does not honor this rule, from call-local whole-inner-layer keepouts, which prevent through-via barrels crossing those layers. The 08:08 continuation used both inner-plane keepouts; successful calls also blocked Bottom and consequently added no vias. Its VCHG_IN/C36 Bottom-only attempt proposed an illegal transition through the inner-layer keepouts and neighboring copper, and persisted no route. That attempt had additional obstacles: it is not an isolated proof that keepouts were its sole failure cause.
Expected: keep signal traces off both inner GND reference layers while allowing normal through-vias with appropriate plane antipads; preserve genuine antenna/hardware exclusions. Actual: the available targeted-route workaround also excludes the desired through-vias. This may be a documented limitation, not necessarily a bug; support should clarify supported semantics.
Minimal supported investigation/reproduction: inspect the saved full-route rule configuration and prior targeted call-local keepout requests; in an isolated support copy, compare a Top-to-Bottom transition requiring a through-via with the two inner layers reserved for GND. No such new test was run here. The exact original keepout payload, native rule UID and isolated failure log were not recovered; request them from server history before treating this as a turnkey reproducer.
Safe request: provide a supported track-only layer prohibition applicable to targeted routing while permitting ordinary through-vias/antipads, or confirm the limitation and recommended safe workflow. Do not remove inner-reference protection, antenna/hardware keepouts, or relax manufacturing clearances. No inner-plane signal routing is authorized.
3. Orphan PROBE_VDD airwire between intentional NCs
Persisted facts. Net PROBE_VDD UID 02baece2-27f0-44e9-8c15-30ab9cc59a95 has zero schematic connections, yet routing state requests J6:1 → D8:3. Both pins are intentional NCs. The report records 157 schematic net records versus 158 layout net nodes. Prior transcript search reports all ten trial segments were removed at #ec60377d, with local Top/Bottom SVG inspection finding no connecting copper. A prior removal/reconciliation attempt failed: the report paraphrases “net was not found”; indexed transcript retrieval reports “net does not exist.” The raw operation response was not recovered, so neither wording is asserted as a verbatim authoritative error log.
Expected: pins with no live schematic net and NC intent should not acquire a routable PCB connection. Actual: persistent extra airwire despite zero schematic membership and zero NC violations in saved scoped checks. The discrepancy is documented; cache corruption versus another representation cause remains unproven.
Minimal read-only reproduction: open the saved checkpoint, inspect schematic NC status for the two exact terminals below, inspect PROBE_VDD net membership, then compare routing-state J6:1 → D8:3. Inspect the existing failed cleanup response in server history rather than repeating deletion. No trial routing is necessary or authorized.
Safe request: reconcile/remove only the orphan PCB net association and stale airwire/cache using a supported, reversible operation, with before/after schematic diff and NC/short/routing-state verification. Preserve J6:2/D8:1 PROBE_NTC, J6:3/D8:2/D8:5 GND, all valid probe copper and both NC markers. Do not route the orphan, replace parts, regenerate all routes or alter NCs to hide it.
Exact native identities
These layout instance/pad IDs were read directly at #236a9f8e. A full pad UID is instance UID + __ + terminal UID. This explicitly corrects indexed-search ambiguity that conflated J2 DP and DN pads and confused part-definition IDs with placed instances.

Table


InstanceNative instance UIDTerminalTerminal UID
J268ca8427-aace-4956-bdc8-36480bd9bf57DP1c075a659-4575-4068-8a48-34beae087e01
J2sameDP2a3b54b4c-d179-4698-a4be-f23d13d8f7e5
J2sameDN12ff29cc4-2477-4430-83c5-ef7111876530
J2sameDN218611d22-2ae5-4717-8799-5645633fe27c
U131d34967d-e622-4102-a9fc-19388912e66cS1c539d2bd-603e-4d1e-977f-3a4ff4ada34d
U13sameS2b77293d5-7003-4593-9171-4354af06b2c0
J67aaf723a-8d65-47d0-ad04-98c92ad8b11a1a055bd1e-cc85-4323-90dd-014ad80677fd
D89dfe94df-ced6-4a80-af5a-59c0449d7a6c31818ead2-23a6-4d65-b7f6-310b1ebef84d
Layout container: 6c1dc0e6-192f-4fef-9567-2c9507274702.defaultlayout; nets container: 6c1dc0e6-192f-4fef-9567-2c9507274702.defaultlayout.Nets. U13 footprint parent includes part-definition ID 35b756f1-9de1-41ba-9e21-508657f94c1c; that is not its layout instance UID. USB net UIDs and the twelve protected segment UIDs were not recovered in this handoff; resolve by net name within the saved snapshot.
Job and revision evidence index

Table


ReferencePersisted significance
auto-layout-37a330e2-6b01-4b09-b185-128953006627Full autoroute, Top 0° / Bottom 90°, inner Forbidden Layers; applied 58 nodes, 70→68 airwires, result unrouteable; campaign attempts 1, best 68, targetedRoutingAllowed=false in that historical run
#f383759dPost-re-layout cleanup: 68 opens (67 real + orphan), six protected USB candidates; scoped safety checks 2026-10-25T05:38:14Z
#c6444c9eR14 correction: 67 opens; before/after USB warnings unchanged; no USB/routing retry in that focused follow-up
#6c591c7fExplicit power repair: 58 opens; USB and orphan left untouched
#236a9f8eSaved report checkpoint: 53 opens (52 real + orphan); scoped check timestamp 2026-10-25T08:08:13.367Z; not a live-board guarantee
#ec60377dIndexed prior transcript: ten orphan trial segments removed; this historical deletion was not repeated here
#22948fe3Historical rollback analysis only: contemporary report said 36 opens, later historical read returned 45; reconstruction discrepancy unresolved, so not a guaranteed restore count
No native targeted-routing operation IDs, failed orphan-removal operation ID, raw request/response attachments, or formal USB/keepout error-code logs were recovered. The full autoroute job above is known from the report even though indexed transcript search did not recover it. Support should retrieve server-side logs using that job, project and revision references. No campaign reset or budget bypass is requested; historical campaign states must not be mistaken for current permission.
Recovery boundaries and evidence completeness
Completed: separate handoff for all three issues; exact directly inspected endpoint IDs; known full-router job and revision references; supported prior-attempt sequence; expected/actual distinction; bounded reproduction outline and preservation requests. Evidence partial: sufficient for triage, not a complete executable reproducer or root-cause proof; missing raw logs/payloads and operation IDs are listed above. Unattempted intentionally: new routing tests, platform repairs, support submission and manufacturing release.
Please investigate on a preserved support snapshot and return a scoped, reversible recovery procedure before touching the active design. No rollback of the live 110 × 100 mm board is authorized, and independent power-region work must be preserved. Do not replay a broad historical revert or global autoroute. The saved report's 53-open state and zero findings in nine scoped categories are not whole-design clean ERC/DRC or fabrication approval; real power/signal opens and current/thermal/USB qualification remain separate work.
  • Triage summary

  • 1. USB rejection after real breakout corrections

  • 2. Forbidden Layers versus through-via keepouts

  • 3. Orphan PROBE_VDD airwire between intentional NCs

  • Exact native identities

  • Job and revision evidence index

  • Recovery boundaries and evidence completeness