Chat
Table
| Assigned item | Status | Native implementation / remaining qualification |
|---|---|---|
| C11, C17, C55 | Completed — copper geometry | Two lands each 0.875 × 1.375 mm at x±0.850 mm, y0; intended Samsung CL21A106KAYNNNE 2012 geometry. Mask +0.05 mm, paste 1:1. |
| C52, C53, C54 | Completed — copper geometry | Two lands each 0.825 × 1.325 mm at x±0.800 mm, y0; intended Samsung CL21A226MAQNNNE 2012 geometry. Mask +0.05 mm, paste 1:1. |
| C48, C49 | Completed — copper geometry | Two 1.10 × 2.05 mm lands at x±1.70 mm, y0, following the inspected Holy Stone C1210X475K101T target. Mask +0.05 mm; paste 1:1. Two new silk label-overlap warnings remain. |
| R45 | Completed — nominal 2512 copper | Two 1.225 × 3.35 mm lands at x±2.9625 mm, y0; retains P1→CHGR_SHUNT_MID and P2→VBAT. Mask +0.05 mm, paste 1:1. Nominal land pattern, not a claimed exact manufacturer-recommended pattern. Kelvin layout and assembly qualification remain later tasks. |
| R96 | Completed — nominal 0805 copper | Two 1.025 × 1.40 mm lands at x±0.9125 mm, y0; mask +0.05 mm, paste 1:1. |
| Q12, Q13 CSD17304Q3 | Completed — copper repair and net readback | Preserved all nine original terminal-bound pad IDs per component. G/S lands 0.50 × 0.63 mm, y−1.435; main D land 2.45 × 1.90 at (0,+0.390); four D fingers 0.50 × 0.41 at y+1.545. Four column centres x−0.975,−0.325,+0.325,+0.975. Main rectangle meets fingers at y1.340, reproducing the comb-shaped copper union rather than filling its notches. Mask +0.05 mm; paste currently 1:1. Final stencil and thermal qualification are not completed. |
| U25 BQ24610RGET exposed pad | Failed / blocked — source terminal mapping | Real 2.45 mm-square pad25 remains unbound. Source declares both GND and EP with pin_number17: EP binds perimeter17; GND creates a synthetic fallback circle. No safe layout-rule-only terminal-binding repair was demonstrated. Do not treat overlapping grounded copper as a repair. |
| C16, C61, C41, D18 and Q6 | Completed — retention check | Existing components retained; Q6 remains DNP. C16 native 0805 lands remain 1.00 × 1.45 at x±0.95; C61 native1206 lands 1.15 × 1.80 at x±1.475; C41 lands0.80 ×0.90 at x±0.70. No new changes to these parts. |
| Other inspected active passives | Completed — retention check only | Native footprint/pad readback covered C3/C4 (1210), C7/C8/C9 (1206), C13/C15/C18/C19/C20 (0805), C10/C14/C37/C50/C51/C56/C57/C58/C60/C67 and R7 (0603). These were not independently requalified or edited. |
| Inherited silk/body assets and label cleanup | Unattempted completion | Some newly enlarged generic parts still render their old small inherited body/silk outlines. Actual pad copper is corrected, but this is not a complete source-footprint/3D-asset replacement. Resolve silhouettes and C48/C49 label overlap before placement/assembly release. |
| Final fabrication export, full-board DRC, assembly release | Unattempted | Board is unrouted; this batch provides no production export or order approval. Prior U9/U17 stencil gates below remain applicable. |
c85cecb4-33b0-498e-a817-8b05dbb454f1), all S remain CHGR_SW (e643368c-cebc-4c23-94d3-292e497a5e66), all D including main drain remain CHGR_IN (c64d927d-473d-4895-b2b2-1c73a20f3b2e). Q13 G remains CHGR_LODRV (50c6b9fb-c6e4-4918-891d-f43314f15a20), S remain GND (7bbe76d5-294c-4c12-87f0-7337e3143ddc), D including main drain remain CHGR_SW. No pad deletion/recreation or board-owned substitute pads were used.33149353-d3e8-4671-880a-7633ad594aa7, version 56e4f30a, reproduces the duplicate17 mapping outside this board. Correct the source EP terminal's physical number to25, retain GND17 and every other perimeter pin, then update/replace the consuming U25 with explicit terminal/net preservation. After that change verify exactly24 perimeter pads plus one real EP25, GND17→GND and EP25→GND, and absence of the synthetic1.6 mm fallback circle. Do not modify the EP25 mount's copper shape as a substitute for binding it. Source creation/publishing and consuming replacement were unattempted in this geometry-only batch; this specification is not an already-created replacement part.commentFileId-4973a4b7279b326049d910390fe2f62355509fa1f4a4f2062462627dea6f2a4e
2150eadcf8fe436b7a3e126c6227451ab6339f35b991d0c3eee4ccf17e4950bd.005a59d174f8a9f826ecee7889ba34ae6ef103162361bdd2fd6341e7cf445f07; visually inspected TI M0143-01 geometry used for Q12/Q13. Automated claim-level citation validation remains unverified.ca5a79b1d6516b7d80f1e4e25e4743af374b498e41b249080d589aa893ee99fa; LR12 body/termination evidence supports the selected nominal2512 pattern, not an exact recommended land-pattern claim. Automated claim-level citation validation remains unverified.C48 C49 Holy Stone 1210 lands, its negative/positive land rules; R45 LR12 nominal 2512 copper, its negative/positive land rules; and the eight Q12 Q13 TI M0143 .../Q12 Q13 drain copper mask paste rules. Existing earlier Samsung/R96 repair rules remain. Keep these selector overrides through layout; changing Package metadata alone is not an equivalent repair.6842dc67-5949-47eb-af67-6c83da2cd70e, version 764aa8a7) and BQ24610RGET, with exact source defects and local workaround limitations. Assigned batch reporting is complete; U25 repair and overall manufacturing completion are not.Table
| Assigned item | Outcome | Evidence |
|---|---|---|
| J1 contact alignment | Completed | Both original contact nodes now y+2.77 mm, x±1.00, size1.00×3.80; tabs remain x±3.35,y−2.93,size1.50×3.40. Native tree, copper/paste SVG and diagnostic KiCad agree. Pin1 remains VEH_IN, pin2 GND; tab NC bindings retained. |
| J2 mechanical NPTH correction | Completed natively | Only the two unnumbered NC plastic-peg locator nodes use padHoleType=HOLE; nominal Ø0.60 and centres x±2.89,y+1.21 unchanged. Native ruleset adds0.20mm keepout; existing−0.31mm paste suppression retained. No copper or paste image remains at either hole. |
| J2 plated shell preservation | Completed | Four original terminal-bound shell slots remain GND/PTH at x±4.325,y+1.71/−2.47: two0.60×1.70 and two0.60×1.40; copper0.90×2.00 and0.90×1.70 respectively. No duplicate shell nodes export. |
| Q10 pinning / physical orientation / bindings | Completed — retained | Manufacturer G1/S2/D3 agrees with schematic and CAD: G1 at(−1.20,+0.95)→VSENSE_GATE, S2 at(−1.20,−0.95)→VSENSE_FET, D3 at(+1.20,0)→VSENSE_EXT. Top-view single drain lead is on the right, gate upper-left/source lower-left. No schematic mismatch. |
| D16 polarity / lands | Completed — retained | CAD K/pad1 at(−1.55,0)→VSENSE_FET; A/pad2 at(+1.55,0)→VSENSE_GATE. Source footprint's silk diode cathode bar is on the left, agreeing with K. Physical cathode band must face pad1/source. No schematic mismatch. |
| Final routed export, independent full-board DRC, assembly release | Unattempted | Board remains unrouted. These diagnostic exports are DO NOT ORDER. U9/U17 segmented top-paste execution remains a final stencil gate, not completed by this batch. |
925d8a1e-aa2f-4246-8d26-038a82361a1b targets exactly the two original contact UIDs.c5b6a561-d93e-4f9e-be81-775607f1b7de targets exactly the two locator UIDs listed in the stable section, with HOLE !important and keepOut=0.20mm !important. Native rule-source readback confirms these win, while the earlier holeSize/position and no-paste rules remain effective. This is an intentional mechanical DFM correction, not an attempt to hide U7 Invalid Pads. The0.20mm design clearance follows JLCPCB NPTH guidance; it is a design clearance, not a fabricated-hole tolerance.Plated,PTH,ComponentDrill contains only the four shell G85 slots; T3 Ø0.600 explicitly NonPlated,NPTH,ComponentDrill contains exactly two round locator hits. Thus no shared-tool global relabelling occurred. CAM must preserve the embedded plating attributes; if a fabricator requires separate drill files, split by these explicit tool attributes into PTH/NPTH files, retaining origins/units and hits unchanged. No copper-removal postprocess is needed because native HOLE already removes locator copper.commentFileId-eb4a2b9ad3b22e14670474ddd37dc0c2db7a0cb1c4076bb443d21742baf4b12d
commentFileId-c8476db49e1a9f46bd3f656d6503571996df46c1b5f6ad470d7b7b00f1bd8932
G::1,S::2,D::3; K::1,A::2) and original numbered CAD asset, not inferred solely from exported names. Native schematic confirms all three sense nets exactly as specified. Selected native checks at 2026-10-22T16:48:12Z: overlapping copper, invalid layer, missing footprints and no-connect violation Success; U7 Invalid Pads remains Informational. Airwires remain Error, expected for the unrouted board. Full external board DRC/placement/thermal/assembly qualification were not run.Table
| Assigned item | Status | Final disposition |
|---|---|---|
| U22 / U23 INA237AIDGSR | Completed | Corrected both DGS0010A footprints to ten 0.30 × 1.45 mm lands, 0.50 pitch, y±2.20 mm rows, R0.05, mask +0.05, paste 1:1. Original was 0.30 × 1.30 at y±2.35. All20 pad identities/bindings retained. DGS is the exact ten-pin package, not DGK. |
| U17 TPS26621DRCR copper | Completed | Applied the already sourced U9 DRC0010J custom EP outline and ten 0.60 × 0.24 mm perimeter lands at x±1.40, 0.50 pitch. EP/RTN/OVP remain USB_RTN, distinct from GND and U9 EXP_RTN. Mask +0.05; perimeter paste 1:1. |
| U17 segmented paste | Unattempted native implementation; final stencil remains blocked | Same independently segmented-paste limitation already demonstrated for U9. Native readback explicitly shows continuous EP paste. Apply the six-window final-file procedure below separately to both U9 and U17; neither stencil is claimed repaired. |
| U18 / U19 / U20 TPS3700DDCR | Completed | Corrected all18 lands to TI DDC example: local 0.60 × 1.10 mm, retaining 90° pad rotations (effective footprint dimensions 1.10 × 0.60); rows x±1.35, y0/±0.95; mask +0.07 and paste 1:1. Original row centres x±1.25 and pitch0.98 were not the reference nominal. |
| J10 S2B-PH-SM4-TB(LF)(SN) | Completed | Retained 2mm pitch, 1.00 × 3.80 contacts and 1.50 × 3.40 tabs. Moved only the two contact centres y2.93→2.77 mm to satisfy the catalog's 5.50mm maximum near-edge setback; tabs remain x±3.35,y−2.93. Pin1 remains VSENSE_EXT; pin2 and tabs remain NC. |
| U15 ADS1115IDGSR | Completed — retained | Ten existing1.45 ×0.30mm lands at x±2.20, pitch0.50 match TI DGS0010A nominal. No geometry mutation needed. |
| U13 TMUX1511PWR | Completed — retained | All14 previously repaired0.45 ×1.50mm lands at y±2.90, pitch0.65 retained. Prior sourced PW0014A correction is still present. |
| D13 exact UMW SS34B / C2758511 | Completed — retained SMB | Manufacturer PDF confirms SMB/DO-214AA, not SMA; page1 explicitly shows pin1 cathode/pin2 anode and page5 orders UMW SS34B (body marking SS34). Live pads2.50 ×2.30mm at x±2.15 exactly match the nominal KiCad D_SMB dimensions/centres. No geometry correction required. K remains VCHG_IN, A remains5V_VEH. Source-property correction is assigned to the circuit writer, not done here. |
| D14 SMCJ33CA-13-F | Completed — retained | Actual3.03 ×3.82mm lands at x±3.43 contain the manufacturer's smaller suggested2.50 ×3.30mm lands at x±3.45. Existing enlarged pattern is retained, not falsely described as an exact nominal match. Bidirectional part has no functional anode/cathode orientation requirement. |
| D15 BAT54WS-7-F | Completed — retained; polarity provenance resolved | Existing1.00 ×0.75mm lands at x±1.17 contain the manufacturer's smaller suggested0.590 ×0.450mm lands at x±1.055. Library CAD pad1 is left, at its cathode stripe; symbol's cathode is also left. Manufacturer establishes band = cathode, but does not assign numerical pins in this drawing: pin1=K is the verified project CAD convention, not a claimed manufacturer numbering statement. Current pin1→VSENSE_BUS, pin2→GND is consistent; no rewiring performed. |
| Full final manufacturing release, routed export and assembly qualification | Unattempted | The board remains unrouted. No production stencil or assembly acceptance is claimed. |
commentFileId-c67f0c72fa79023e6f62dfb5be243775d1a7aeacc768dd5a9c05c0fe43024561
commentFileId-ffc67d1ffb8262d76f087903db72f925f355e4321d4f98e607c3970888781a51
commentFileId-d7192bc023e1a1d87a2d9652a2613ffb0d629708b6f9a6c096f166a274c3f234
e25e9f4acef5b55585afebc48c685e151fd0d2f33a5c3c61f9fdf0389e19ae67; this supports nominal layout, not independent tolerance/thermal qualification.commentFileId-767ca8ea8436ced10a7099be1550218dba7a9db50307fea770a70bd096fa5755
bee4823e…,8e225834…; shared U9/U17 EP selector 50e5a005… (U9 geometry unchanged); U22/U23 lands/rows ca1d57c4…,c465bcaf…,83439ee3…; U18/U19/U20 lands/rows/pitch 9c14821c…,835683eb…,a0859f50…,80c89847…,849f13d8…; J10 contacts 4116b184…. No new parts/nets or pad identities were created or deleted.Table
| Assigned item | Status | Evidence / remaining action |
|---|---|---|
| U7 nominal footprint retention | Completed | All 32 exported pads remain 0.70 × 1.80 mm; native paste readback retains R0.175, 1:1 openings, rows at ±7.40 mm and existing pin orientation. Official KiCad nominal baseline accepted for engineering layout. Manufacturer revision applicability remains advisory; no further datum loop required. |
| U9 copper and EXP_RTN retention | Completed | Native PAD/RTN/OVP effective net remains 718fbc2f-c70e-484e-b7f3-287d0a315ce7; diagnostic KiCad identifies EXP_RTN. GND remains separate. Actual copper Gerber contains the repaired custom EP region, 1.65 × 3.40 mm outer bounding box, and ten 0.60 × 0.24 mm perimeter lands. |
| U9 native six-window paste | Failed to demonstrate a safe supported native implementation | No rejected paste-layer mutation was retried. Source asset inspection and rule definitions did not establish an independent paste-only layer/import path that preserves existing component-owned pad bindings. Asset replacement/import was unattempted, rather than risking the completed copper and terminal mapping. Native and Gerber paste still contain one continuous EP region. |
| U9 final export correction specification | Completed | Exact six-window, transform and acceptance requirements below. Execution on the final routed export is unattempted and remains a stencil-release gate. No corrected production stencil is claimed. |
| J2 inactive duplicate ambiguity | Completed — absent from actual exports | Diagnostic Gerber/Excellon contains exactly four shell slots, two locating holes and no three inactive shell-node duplicates. The drawing discrepancy in layout_2d was not a duplicate physical hole. No duplicate deletion or drill deduplication is required. |
| J2 locating-hole stencil paste | Completed — native correction | Actual initial paste Gerber had two Ø0.60 mm flashes over locating holes. One two-node selector ruleset suppresses those nonsoldered locating-hole apertures. Re-export proves both are gone, with copper/drill/mask retained. |
| J5 / J7 repaired tabs | Completed — retained | Each exported footprint has eight 0.60 × 1.55 mm contacts and two 1.20 × 1.80 mm tabs. Native tab positions ±4.80, −1.935 mm and matching paste openings read back. |
| Full manufacturing qualification / final production export | Unattempted | Unrouted board; concurrent circuit writer active. These diagnostic snapshots must not be ordered. |
863d3171-b7f7-4179-b2a4-c59c213cf050, setting solderPasteMaskExpansion = -0.31mm !important on exactly these two component-owned nodes:68ca8427-aace-4956-bdc8-36480bd9bf57__d5150ac1-7fac-4e9b-8ed4-ab4b4aff04b8.defaultFootprint.mounts.a77877e08178fc1a3b0e726bd7c2549e68ca8427-aace-4956-bdc8-36480bd9bf57__d5150ac1-7fac-4e9b-8ed4-ab4b4aff04b8.defaultFootprint.mounts.394588911379d6b6624272c8e38cd8bfesp32-lorawan-can-battery-monitor-f_paste.gbr, inside the final fabrication/stencil ZIP. Identify by TF.FileFunction,Paste,Top, not filename alone. Do not change top copper, masks, drills, bottom paste, netlist or placement files. If the assembler uses ODB++/IPC-2581 or generates its own stencil from copper, provide the same six-window specification and obtain written acceptance; a corrected Gerber is ineffective if the assembler ignores it.Table
| Window | Centre x (mm) | Centre y (mm) | Width × height (mm) | Corner radius (mm) |
|---|---|---|---|---|
| Main upper | 0 | +0.63 | 1.50 × 1.06 | 0.05 |
| Main lower | 0 | −0.63 | 1.50 × 1.06 | 0.05 |
| Prong upper left | −0.25 | +1.53 | 0.25 × 0.34 | 0.05 |
| Prong upper right | +0.25 | +1.53 | 0.25 × 0.34 | 0.05 |
| Prong lower left | −0.25 | −1.53 | 0.25 × 0.34 | 0.05 |
| Prong lower right | +0.25 | −1.53 | 0.25 × 0.34 | 0.05 |
u9-stencil-current
thru_hole, and the actual exported Excellon marks their Ø0.60 tool as Plated/PTH, with copper discs equal to hole diameter (no nominal annular ring). This classification was not changed because the task required retaining corrected copper/slots and there is no verified purchased-stock plating requirement. Before fabrication, obtain the fabricator's disposition of these mechanical locating holes: approved finished Ø0.60 plated mechanical holes, or a documented NPTH correction with appropriate copper clearance. Do not silently relabel the shared Ø0.60 tool NPTH: the same tool also cuts the four plated shell slots. If an export-only NPTH correction is selected, split the two round locator hits into a separate NPTH drill artifact and verify copper clearance; shell slots must remain PTH. This is a specific DFM action, not evidence of duplicate drills.Table
| Assigned item | Follow-up outcome | Remaining blocker / qualification |
|---|---|---|
| U4 independent rounded EP paste | Failed — supported mutation path not demonstrated. Earlier copper and 1.55-square paste retained. | Exact independent R0.05 aperture needs supported paste-only implementation or assembler acceptance of existing square corners. |
| U9 copper repair | Completed. Ten perimeter lands and custom EP copper corrected; read back in tree and copper SVG. | Does not close stencil qualification. |
| U9 segmented EP paste | Failed — supported mutation path not demonstrated. Full continuous custom-shape paste remains. | Six separate apertures must be implemented/verified or an alternative approved by assembly engineering before release. |
| U7 pad repair | Completed to official KiCad nominal CAD. All 32 lands resized/repositioned; mask and paste read back. | Manufacturer drawing/CAD side-normal interpretation and assembly stencil acceptance are not certified by this CAD match. Informational Invalid Pads remains. |
| J2 drawing reconciliation and geometry | Completed against visually inspected HRO 2020-12-08 pattern, replacing the older 2015 reference target; same MPN retained. Copper and drill readback completed. | Purchased-stock revision, slot manufacture, and inactive duplicate-node Gerber/drill behavior still need release verification. |
| U13 PW0014A | Completed. Same verified correction as U11, all 14 lands and effective net IDs read back. | No new local blocker. |
| U12 and U14 DBZ0003A | Completed. Six lands corrected and orientation retained; copper-size mask/paste geometry and effective nets inspected. | No new local geometry blocker; automated citation validation of the visually inspected stencil detail remained unavailable. |
| U11, J5, J7 | Completed in preceding batch; retained. | No additional edits attempted in this follow-up. |
| Fabrication export, assembly approval, full PCB completion | Unattempted, outside this batch. | PCB remains unrouted and not manufacturing-ready. |
size field is not its bounding box. EP, RTN and OVP retain net UID 718fbc2f-c70e-484e-b7f3-287d0a315ce7 (EXP_RTN); GND remains the separate 7bbe76d5-294c-4c12-87f0-7337e3143ddc. Final paste SVG explicitly shows the continuous EP outline, not six windows. Earlier TI target and validated stencil citation remain in the historical U9 section below.commentFileId-0fcef6edb260eec13544eb4d345c8931775b8ff125cb2ec075e8a2111e939635
commentFileId-b0b2ac33856dd14e9973024cd9a3cf861aa50a1c4bea3027994c1f02d34ed6a5
commentFileId-768a3fa2b0286e97654bfeecfd16047ec55b3e8895604faf9c9c6136c8dd91a8
Top Solder Paste was rejected as a supported pad/shape layer in the exercised native path. Seven temporary paste-test rectangles were disabled after deletion was rejected; they are not active stencil apertures. Do not infer a universal platform limitation or count them as a completed stencil repair.layout_2d; actual export behavior remains unverified. Do not mistake that inspection rendering for proof of physical duplicate holes. Attempts to submit follow-up tool feedback failed; no new feedback ticket is claimed.U7..., U9..., J2 HRO 2020..., U13 TI..., and U12/U14 TI DBZ.... Historical ten-ruleset accounting below applies only to the preceding batch. The current repair is intentionally not represented as a fresh library-part release.Table
| Item | Review | Mutation / disposition |
|---|---|---|
| U4 BQ24075RGTR | Completed | Completed: nominal copper, mask and paste-size correction. Unattempted: independent exposed-pad paste corner-radius refinement; exact stencil-example compliance remains open. |
| U11 TMUX1511PWR | Completed | Completed: all 14 lands and row positions corrected and read back. |
| J5 SM08B-SRSS-TB(LF)(SN) | Completed | Completed: two reinforcement lands corrected; signal lands retained. |
| J7 SM08B-SRSS-TB(LF)(SN) | Completed | Completed: same correction as J5. |
| U7 RAK3172-T-9-SM-I | Completed comparison; full geometry qualification failed | Unattempted repair: unresolved side-pad normal-offset/body-datum reconciliation. Unchanged; quality report filed. |
| U9 TPS26621DRCR | Completed comparison; reference-pattern qualification failed | Unattempted repair: full custom-copper and segmented-stencil repair not demonstrated in this bounded pass. Unchanged; exact repair specified below and quality report filed. |
| J2 TYPE-C-31-M-12, C165948 | Completed comparison; current-revision qualification failed | Unattempted repair: retrieved manufacturer drawing revision not reconciled with current stock; latest attached LCSC URL returned HTML. Unchanged; quality report filed. |
commentFileId-ea75f40138dc6db53d2f4d290dd4ea631e00f827128d92718f11e224875c63ea
Table
| Feature | Final live geometry | Manufacturer example / conclusion |
|---|---|---|
| Perimeter pads 1–16 | 0.24 × 0.60, corner R0.05 | Matches nominal land example |
| Pitch | 0.50 | Matches |
| Opposing pad centres | 2.80; radial positions ±1.40 | Matches |
| EP17, GND | 1.68 × 1.68 centred at 0,0 | Matches nominal copper example |
| Mask | +0.05 per side; EP opening 1.78 × 1.78 | NSMD implementation; verified in live SVG |
| Perimeter paste | Same nominal size as copper, R0.05 | Verified live |
| EP paste | 1.55 × 1.55, inset −0.065 per side | Nominal size/approximately 85% area matches example; actual live aperture corners are square, not example R0.05 |
commentFileId-29e28b5464546df2fa5743694aec259992282d7c2e6a958fc36d338ec6f11dd7
Table
| Feature | Final live | Manufacturer example |
|---|---|---|
| Pads 1–14 | 0.45 × 1.50, R0.05 | 0.45 × 1.50 |
| Pitch | 0.65 | 0.65 |
| Opposing row centres | 5.80, y = ±2.90 | 5.80 |
| Mask opening | 0.55 × 1.60 | +0.05 per side implementation |
| Paste opening | 0.45 × 1.50, R0.05 | Nominal 1:1 pattern |
commentFileId-9a8c3c1942be3c07df839fd1e0089893066aec51a91a76ecdcbf70ed68ea31c4
Table
| Feature | Before | Final live / guideline |
|---|---|---|
| Eight signal lands | 0.60 × 1.55, 1.00 pitch | Retained; matches nominal guideline |
| Reinforcement pads 9,10 | 1.50 × 2.00 | 1.20 × 1.80 |
| Reinforcement x centres | ±4.80 | Retained |
| Reinforcement y centre | −1.940 | −1.935, relative to unchanged signal row y=1.940 |
| Mask/paste expansion | 0 | Retained; SVG shows matching copper-size openings |
pad_layout
mechanical_dimension
commentFileId-35982a4781266689f8aedfbb4ac080576d33142fab22d895460119a50d593b62
commentFileId-496f35c3908c5ddc6025230f7c61d4eef701eb3799c8205626a105820f5b27be
Table
| Feature | Live, unchanged | Reference / qualification |
|---|---|---|
| 32 pads | 0.80 × 1.80 | Drawing nominal 0.70 × 1.80 |
| Pitch | 1.00 | Matches nominal |
| Top/bottom row y | ±7.288 | Drawing-derived nominal ±7.40 in present orientation |
| Top-row x span | −5.32 … +5.68 | Body/drawing-derived −5.25 … +5.75 |
| Side-row x | ±7.569 | Unresolved normal-offset datum, not safely inferred from pitch alone |
| Mask/paste | 0 expansion, full rectangular copper-size openings on all32 pads | Inspected; no separately qualified stencil prescription |
commentFileId-9d4d52e8bdb1f834bcf7d58a884ac30ad82dbbb23fd4fc64ea8052c4f8c96c01
Table
| Feature | Live, unchanged | TI nominal example / repair target |
|---|---|---|
| Pads1–10 | 0.80 × 0.30 | 0.60 × 0.24, R0.05 |
| Pitch | 0.50 | 0.50 |
| Opposing row centres | 3.00, x±1.50 | 2.80, x±1.40 |
| EP11 main body | 1.62 × 2.50, yoffset−0.01 | 1.65 × 2.40, centred |
| EP overall height including prongs | 3.52 | 3.40 |
| EP prongs | Existing custom shape | Four0.25-wide prongs, x centres±0.25, R0.05 pattern |
| EP paste | Continuous full custom shape, 0 inset | Two1.50 × 1.06 main windows plus four0.25 × 0.34 prong windows |
commentFileId-29e542efa9be976ea88b8ec2eea0105964fecb793a7e810a95ed44996c4bbae7
Table
| Feature | Live, unchanged | Retrieved HRO drawing |
|---|---|---|
| Small contact lands | Sixteen0.30 × 1.30, adjacent same-net power/GND lands touching | Twelve physical lands: eight0.30 × 1.45 and four merged0.60 × 1.45 |
| Merged power/GND centres | Separate terminal-bound pads | x±2.45 and±3.25 |
| Shell x centres | ±4.33 | ±4.32 |
| Shell row span | 4.18 | 4.18 |
| Shell slots, longer pair | 0.80 × 1.70 | 0.60 × 1.70 |
| Shell slots, shorter pair | 0.80 × 1.40 | 0.60 × 1.20 |
| Shell copper, longer pair | 1.20 × 2.10 | 1.00 × 2.10 |
| Shell copper, shorter pair | 1.20 × 1.80 | 1.00 × 1.60 |
| Locating holes | Ø0.75 at x±2.90 | Ø0.65 at x±2.89 |
Table
| Ruleset | UID | Scope |
|---|---|---|
| U4 TI RGT0016C pad geometry | ef6e9685-feab-47d0-9cd7-6eaf6933bc96 | All17 U4 pads: corner and mask only |
| U4 TI left row2.8mm | 38f07c24-30a1-493d-b76a-eeea7bc5ade1 | TS, BAT_1, BAT_2, ~CE |
| U4 TI right row2.8mm | 8f69a84d-d8fa-4b1b-a95d-4927b5e4e1bc | ~CHG, OUT_1, OUT_2, ILIM |
| U4 TI top row2.8mm | 0f7921aa-ecd9-45f6-9ae9-d8cc5f69d8c0 | ISET, SYSOFF, TMR, IN |
| U4 TI bottom row2.8mm | bee36cd7-f7c7-4d1f-bba8-9135e54b922c | EN2, EN1, ~PGOOD, VSS |
| U4 TI exposed pad and paste | 644b581b-e26e-49bb-9fe1-2b316ca29386 | EP17 size and paste inset |
| JST reinforcement lands | 8587f9bb-0936-44d4-9409-6aada72c8b28 | J5/J7 pads9,10 only |
| U11 TI PW0014A lands | 18e9832e-efed-47f9-9f38-e1283d52bf4e | All14 U11 lands |
| U11 TI pins1 through7 | 28610f06-5cc8-4db0-b0fd-19457f16d515 | Bottom row y−2.90 |
| U11 TI pins8 through14 | 2a045e81-e5cf-4ed5-b7ab-69bfe6e6fd4b | Top row y+2.90 |
__ + terminal UID. U4 component: bd9f82b7-6e86-4d67-897d-ed47f3fb4792; EP17 terminal: 80cd6337-6c66-4186-b16c-41eea87dc85a. U11 component: 74f1a6a8-3668-46a2-a745-b9c8deb8c9ca, pads1–14 retained. J5 component: beb8b6a3-7cf4-4563-b54f-a7715f1b0b98; J7 component: bcc39374-79ad-4160-9006-600b3b519495; pad9 terminal: d8b269f5-7197-41ec-b7a9-ab3e1abefc99; pad10 terminal: 42959fa1-c578-47c6-9b58-dc590320af5c. Full perimeter UID selectors are retained in the rulesets above.rak-pin
u9-stencil
j2-detail-full
Active charging-footprint repair — 2026-10-23
Verification evidence and severity
U25 exact repair handoff
Retained source evidence and local rules
Final adjacent DFM and sense-block verification — 2026-10-22
Sources, implementation and verification
Expanded new-part closure — 2026-10-22
Sources and derivation
Verification and finite release gates
Stable-footprint closure — 2026-10-22
Exact native change and layout handoff
U9 exact final stencil postprocess requirements
J2 actual export findings
Finite severity and verification
Follow-up disposition — 2026-10-20
Final live geometry and evidence
Tool limitations and final checks
Historical initial batch (retained for traceability)
Scope and disposition
Measured versus manufacturer reference
U4 — BQ24075RGTR, RGT0016C
U11 — TMUX1511PWR, PW0014A
J5 and J7 — JST SM08B-SRSS-TB(LF)(SN)
U7 — RAK3172-T-9-SM-I
U9 — TPS26621DRCR, DRC0010J
J2 — HRO TYPE-C-31-M-12, LCSC C165948
Local changes and traceability
Verification evidence and limits
Retained additional source evidence