Chat


How can I help you?

Explain project
Write a project description
Find schematic issues

Pre-layout footprint review
Active charging-footprint repair — 2026-10-23
Bounded geometry batch; not manufacturing release. Existing component and pad identities and electrical bindings were preserved. No schematic wiring, placement, routing or manufacturing-profile changes were made. The dimensions in the following table are final native readbacks, not independent assembly qualification.

Table


Assigned itemStatusNative implementation / remaining qualification
C11, C17, C55Completed — copper geometryTwo lands each 0.875 × 1.375 mm at x±0.850 mm, y0; intended Samsung CL21A106KAYNNNE 2012 geometry. Mask +0.05 mm, paste 1:1.
C52, C53, C54Completed — copper geometryTwo lands each 0.825 × 1.325 mm at x±0.800 mm, y0; intended Samsung CL21A226MAQNNNE 2012 geometry. Mask +0.05 mm, paste 1:1.
C48, C49Completed — copper geometryTwo 1.10 × 2.05 mm lands at x±1.70 mm, y0, following the inspected Holy Stone C1210X475K101T target. Mask +0.05 mm; paste 1:1. Two new silk label-overlap warnings remain.
R45Completed — nominal 2512 copperTwo 1.225 × 3.35 mm lands at x±2.9625 mm, y0; retains P1→CHGR_SHUNT_MID and P2→VBAT. Mask +0.05 mm, paste 1:1. Nominal land pattern, not a claimed exact manufacturer-recommended pattern. Kelvin layout and assembly qualification remain later tasks.
R96Completed — nominal 0805 copperTwo 1.025 × 1.40 mm lands at x±0.9125 mm, y0; mask +0.05 mm, paste 1:1.
Q12, Q13 CSD17304Q3Completed — copper repair and net readbackPreserved all nine original terminal-bound pad IDs per component. G/S lands 0.50 × 0.63 mm, y−1.435; main D land 2.45 × 1.90 at (0,+0.390); four D fingers 0.50 × 0.41 at y+1.545. Four column centres x−0.975,−0.325,+0.325,+0.975. Main rectangle meets fingers at y1.340, reproducing the comb-shaped copper union rather than filling its notches. Mask +0.05 mm; paste currently 1:1. Final stencil and thermal qualification are not completed.
U25 BQ24610RGET exposed padFailed / blocked — source terminal mappingReal 2.45 mm-square pad25 remains unbound. Source declares both GND and EP with pin_number17: EP binds perimeter17; GND creates a synthetic fallback circle. No safe layout-rule-only terminal-binding repair was demonstrated. Do not treat overlapping grounded copper as a repair.
C16, C61, C41, D18 and Q6Completed — retention checkExisting components retained; Q6 remains DNP. C16 native 0805 lands remain 1.00 × 1.45 at x±0.95; C61 native1206 lands 1.15 × 1.80 at x±1.475; C41 lands0.80 ×0.90 at x±0.70. No new changes to these parts.
Other inspected active passivesCompleted — retention check onlyNative footprint/pad readback covered C3/C4 (1210), C7/C8/C9 (1206), C13/C15/C18/C19/C20 (0805), C10/C14/C37/C50/C51/C56/C57/C58/C60/C67 and R7 (0603). These were not independently requalified or edited.
Inherited silk/body assets and label cleanupUnattempted completionSome newly enlarged generic parts still render their old small inherited body/silk outlines. Actual pad copper is corrected, but this is not a complete source-footprint/3D-asset replacement. Resolve silhouettes and C48/C49 label overlap before placement/assembly release.
Final fabrication export, full-board DRC, assembly releaseUnattemptedBoard is unrouted; this batch provides no production export or order approval. Prior U9/U17 stencil gates below remain applicable.
Verification evidence and severity
Read-only native tree checked all24 pads of C48/C49/R45/Q12/Q13 after the final ruleset mutation. Separate native mask/paste SVG covered all14 instances C11/C17/C52/C53/C54/C55/C48/C49/R45/R96/Q12/Q13/C61/C41, confirming the dimensions and apertures above. Additional native tree covered66 footprint/pad nodes of the retained-passive set. This is native readback, not independent Gerber verification or a complete netlist checksum.
Q12 G remains CHGR_HIDRV (c85cecb4-33b0-498e-a817-8b05dbb454f1), all S remain CHGR_SW (e643368c-cebc-4c23-94d3-292e497a5e66), all D including main drain remain CHGR_IN (c64d927d-473d-4895-b2b2-1c73a20f3b2e). Q13 G remains CHGR_LODRV (50c6b9fb-c6e4-4918-891d-f43314f15a20), S remain GND (7bbe76d5-294c-4c12-87f0-7337e3143ddc), D including main drain remain CHGR_SW. No pad deletion/recreation or board-owned substitute pads were used.
Latest mutation feedback reported Warning: two C48/C49 silk-label overlaps and two Component Overrides findings. The latter indicate local overrides and are not themselves evidence of electrical errors. Error: U25 real EP25 remains unbound; source mapping must be corrected before placement/release. Warning: generic inherited silk/body mismatch and final stencil/thermal qualification remain. No overall DRC-clean claim is made.
U25 exact repair handoff
Published source part 33149353-d3e8-4671-880a-7633ad594aa7, version 56e4f30a, reproduces the duplicate17 mapping outside this board. Correct the source EP terminal's physical number to25, retain GND17 and every other perimeter pin, then update/replace the consuming U25 with explicit terminal/net preservation. After that change verify exactly24 perimeter pads plus one real EP25, GND17→GND and EP25→GND, and absence of the synthetic1.6 mm fallback circle. Do not modify the EP25 mount's copper shape as a substitute for binding it. Source creation/publishing and consuming replacement were unattempted in this geometry-only batch; this specification is not an already-created replacement part.
TI RGE0024B drawing4219013/A (05/2017) was visually inspected, showing distinct pad25 and perimeter17. The retained drawing is

commentFileId-4973a4b7279b326049d910390fe2f62355509fa1f4a4f2062462627dea6f2a4e

bq-rge24-board.png. Automated claim-level datasheet citation validation is unverified for these graphical dimensions; do not confuse visual evidence with a validated inline citation.
Retained source evidence and local rules
  • bq, SHA256 2150eadcf8fe436b7a3e126c6227451ab6339f35b991d0c3eee4ccf17e4950bd.
  • csd, SHA256 005a59d174f8a9f826ecee7889ba34ae6ef103162361bdd2fd6341e7cf445f07; visually inspected TI M0143-01 geometry used for Q12/Q13. Automated claim-level citation validation remains unverified.
  • uniroyal, SHA256 ca5a79b1d6516b7d80f1e4e25e4743af374b498e41b249080d589aa893ee99fa; LR12 body/termination evidence supports the selected nominal2512 pattern, not an exact recommended land-pattern claim. Automated claim-level citation validation remains unverified.
  • Samsung and Holy Stone source-to-dimension claims in this section are citation-unverified; the numeric entries above are verified native implementation measurements. Preserve this distinction in release review.
Final14 local rulesets are named C48 C49 Holy Stone 1210 lands, its negative/positive land rules; R45 LR12 nominal 2512 copper, its negative/positive land rules; and the eight Q12 Q13 TI M0143 .../Q12 Q13 drain copper mask paste rules. Existing earlier Samsung/R96 repair rules remain. Keep these selector overrides through layout; changing Package metadata alone is not an equivalent repair.
Part-quality feedback was successfully filed for both CSD17304Q3 (source 6842dc67-5949-47eb-af67-6c83da2cd70e, version 764aa8a7) and BQ24610RGET, with exact source defects and local workaround limitations. Assigned batch reporting is complete; U25 repair and overall manufacturing completion are not.
Final adjacent DFM and sense-block verification — 2026-10-22
This section supersedes the older J1 follow-up and J2 locator-PTH warning below. The prior D15 review is historical: the circuit writer removed D15 and added Q10/D16. This footprint writer changed only J1 contact positions and the two J2 mechanical locator classifications/clearance. No placement, routing, nets, terminal bindings, U7, or other prior repaired rules were changed.

Table


Assigned itemOutcomeEvidence
J1 contact alignmentCompletedBoth original contact nodes now y+2.77 mm, x±1.00, size1.00×3.80; tabs remain x±3.35,y−2.93,size1.50×3.40. Native tree, copper/paste SVG and diagnostic KiCad agree. Pin1 remains VEH_IN, pin2 GND; tab NC bindings retained.
J2 mechanical NPTH correctionCompleted nativelyOnly the two unnumbered NC plastic-peg locator nodes use padHoleType=HOLE; nominal Ø0.60 and centres x±2.89,y+1.21 unchanged. Native ruleset adds0.20mm keepout; existing−0.31mm paste suppression retained. No copper or paste image remains at either hole.
J2 plated shell preservationCompletedFour original terminal-bound shell slots remain GND/PTH at x±4.325,y+1.71/−2.47: two0.60×1.70 and two0.60×1.40; copper0.90×2.00 and0.90×1.70 respectively. No duplicate shell nodes export.
Q10 pinning / physical orientation / bindingsCompleted — retainedManufacturer G1/S2/D3 agrees with schematic and CAD: G1 at(−1.20,+0.95)→VSENSE_GATE, S2 at(−1.20,−0.95)→VSENSE_FET, D3 at(+1.20,0)→VSENSE_EXT. Top-view single drain lead is on the right, gate upper-left/source lower-left. No schematic mismatch.
D16 polarity / landsCompleted — retainedCAD K/pad1 at(−1.55,0)→VSENSE_FET; A/pad2 at(+1.55,0)→VSENSE_GATE. Source footprint's silk diode cathode bar is on the left, agreeing with K. Physical cathode band must face pad1/source. No schematic mismatch.
Final routed export, independent full-board DRC, assembly releaseUnattemptedBoard remains unrouted. These diagnostic exports are DO NOT ORDER. U9/U17 segmented top-paste execution remains a final stencil gate, not completed by this batch.
Sources, implementation and verification
J1 uses the same previously inspected JST SM4 component-side drawing and derivation as J10 below: tab outer edge−4.63, contact near edge+0.87, difference5.50mm; overall span9.30mm. See the retained JST drawing and PDF in the expanded closure. Graphical source dimensions remain visually inspected evidence rather than invented machine citations. New J1 ruleset 925d8a1e-aa2f-4246-8d26-038a82361a1b targets exactly the two original contact UIDs.
J2 retains the previously inspected HRO2020-12-08 drawing geometry and local datum, including insertion toward−Y; no dimensions or tolerances were invented. New ruleset c5b6a561-d93e-4f9e-be81-775607f1b7de targets exactly the two locator UIDs listed in the stable section, with HOLE !important and keepOut=0.20mm !important. Native rule-source readback confirms these win, while the earlier holeSize/position and no-paste rules remain effective. This is an intentional mechanical DFM correction, not an attempt to hide U7 Invalid Pads. The0.20mm design clearance follows JLCPCB NPTH guidance; it is a design clearance, not a fabricated-hole tolerance.
Actual diagnostic drill export uses one MixedPlating Excellon file with distinct tools, not separate files: T1 Ø0.600 explicitly Plated,PTH,ComponentDrill contains only the four shell G85 slots; T3 Ø0.600 explicitly NonPlated,NPTH,ComponentDrill contains exactly two round locator hits. Thus no shared-tool global relabelling occurred. CAM must preserve the embedded plating attributes; if a fabricator requires separate drill files, split by these explicit tool attributes into PTH/NPTH files, retaining origins/units and hits unchanged. No copper-removal postprocess is needed because native HOLE already removes locator copper.
Gerbonara1.6.3 reparsed top, bottom and both inner copper layers plus top paste: zero objects overlap either locator. Conservative object-bounding-box hole-edge gaps are 0.20009999mm top and 0.685mm bottom/inner, satisfying the0.20mm local clearance at this unrouted snapshot. Both locator drills remain Ø0.60; all four shell slots match the prior corrected dimensions and nets. Recheck clearance after routing/pours. KiCad diagnostic export omits native clearance overrides; do not round-trip it as a substitute project or assume its external DRC inherits native rules.
Q10 source: Vishay Si2325DS PDF, page1: G=1,S=2,D=3. The actual top-view graphic was visually inspected and agrees directly with live orientation.

commentFileId-eb4a2b9ad3b22e14670474ddd37dc0c2db7a0cb1c4076bb443d21742baf4b12d

Retained pinning image. Three existing1.00×0.70mm lands at x±1.20 with1.90mm two-pin pitch exactly match the selected published SOT-23W CAD asset; retained as a standard nominal footprint, not claimed an exact copy of Vishay's smaller minimum-pad example.

commentFileId-c8476db49e1a9f46bd3f656d6503571996df46c1b5f6ad470d7b7b00f1bd8932

Inspected minimum-pad example. No geometry defect requiring mutation was identified.
D16 manufacturer package is SOD123, and band=cathode. Manufacturer suggested pads0.900×0.950mm with overall span4.050mm imply centres±1.575mm; actual1.00×1.20 at±1.55 contain those smaller suggested lands, so retain them. Manufacturer does not assign numeric diode pins in this drawing; K1/A2 is the inspected project CAD mapping, not a manufacturer numbering claim. Exact source footprint. Info / source-property handoff: its inherited Package or Case Code says SOD-123F, while the exact manufacturer PDF says SOD123. Geometry is adequate; this writer did not change procurement/source properties.
Diagnostic KiCad exports use terminal names G/S/D and K/A rather than numerical pad strings. Numerical mapping was therefore checked against the native schematic (G::1,S::2,D::3; K::1,A::2) and original numbered CAD asset, not inferred solely from exported names. Native schematic confirms all three sense nets exactly as specified. Selected native checks at 2026-10-22T16:48:12Z: overlapping copper, invalid layer, missing footprints and no-connect violation Success; U7 Invalid Pads remains Informational. Airwires remain Error, expected for the unrouted board. Full external board DRC/placement/thermal/assembly qualification were not run.
Remaining finite gates: U9 and U17 each require the six-window final top-stencil procedure below or a documented assembler-approved alternative; J2 shell pin-in-paste versus selective/hand soldering still needs assembly-process disposition. J1 alignment and J2 locator PTH/zero-annulus are now closed, not outstanding owner questions. Exact example paste-corner radius alone is not a separate hard release blocker. Batch completion does not imply manufacturing release.
Expanded new-part closure — 2026-10-22
This later section expands the preceding writer's scope to U22/U23, D14, J10, D15, U15, U17, U18/U19/U20, U13 and D13. It supersedes the earlier statement that U15 and later parts were outside scope. No schematic connections, part identities, placements, routing or manufacturing-profile rules were changed by this footprint writer. Batch completion is not board/manufacturing completion.

Table


Assigned itemStatusFinal disposition
U22 / U23 INA237AIDGSRCompletedCorrected both DGS0010A footprints to ten 0.30 × 1.45 mm lands, 0.50 pitch, y±2.20 mm rows, R0.05, mask +0.05, paste 1:1. Original was 0.30 × 1.30 at y±2.35. All20 pad identities/bindings retained. DGS is the exact ten-pin package, not DGK.
U17 TPS26621DRCR copperCompletedApplied the already sourced U9 DRC0010J custom EP outline and ten 0.60 × 0.24 mm perimeter lands at x±1.40, 0.50 pitch. EP/RTN/OVP remain USB_RTN, distinct from GND and U9 EXP_RTN. Mask +0.05; perimeter paste 1:1.
U17 segmented pasteUnattempted native implementation; final stencil remains blockedSame independently segmented-paste limitation already demonstrated for U9. Native readback explicitly shows continuous EP paste. Apply the six-window final-file procedure below separately to both U9 and U17; neither stencil is claimed repaired.
U18 / U19 / U20 TPS3700DDCRCompletedCorrected all18 lands to TI DDC example: local 0.60 × 1.10 mm, retaining 90° pad rotations (effective footprint dimensions 1.10 × 0.60); rows x±1.35, y0/±0.95; mask +0.07 and paste 1:1. Original row centres x±1.25 and pitch0.98 were not the reference nominal.
J10 S2B-PH-SM4-TB(LF)(SN)CompletedRetained 2mm pitch, 1.00 × 3.80 contacts and 1.50 × 3.40 tabs. Moved only the two contact centres y2.93→2.77 mm to satisfy the catalog's 5.50mm maximum near-edge setback; tabs remain x±3.35,y−2.93. Pin1 remains VSENSE_EXT; pin2 and tabs remain NC.
U15 ADS1115IDGSRCompleted — retainedTen existing1.45 ×0.30mm lands at x±2.20, pitch0.50 match TI DGS0010A nominal. No geometry mutation needed.
U13 TMUX1511PWRCompleted — retainedAll14 previously repaired0.45 ×1.50mm lands at y±2.90, pitch0.65 retained. Prior sourced PW0014A correction is still present.
D13 exact UMW SS34B / C2758511Completed — retained SMBManufacturer PDF confirms SMB/DO-214AA, not SMA; page1 explicitly shows pin1 cathode/pin2 anode and page5 orders UMW SS34B (body marking SS34). Live pads2.50 ×2.30mm at x±2.15 exactly match the nominal KiCad D_SMB dimensions/centres. No geometry correction required. K remains VCHG_IN, A remains5V_VEH. Source-property correction is assigned to the circuit writer, not done here.
D14 SMCJ33CA-13-FCompleted — retainedActual3.03 ×3.82mm lands at x±3.43 contain the manufacturer's smaller suggested2.50 ×3.30mm lands at x±3.45. Existing enlarged pattern is retained, not falsely described as an exact nominal match. Bidirectional part has no functional anode/cathode orientation requirement.
D15 BAT54WS-7-FCompleted — retained; polarity provenance resolvedExisting1.00 ×0.75mm lands at x±1.17 contain the manufacturer's smaller suggested0.590 ×0.450mm lands at x±1.055. Library CAD pad1 is left, at its cathode stripe; symbol's cathode is also left. Manufacturer establishes band = cathode, but does not assign numerical pins in this drawing: pin1=K is the verified project CAD convention, not a claimed manufacturer numbering statement. Current pin1→VSENSE_BUS, pin2→GND is consistent; no rewiring performed.
Full final manufacturing release, routed export and assembly qualificationUnattemptedThe board remains unrouted. No production stencil or assembly acceptance is claimed.
Sources and derivation
  • TI INA237 datasheet, DGS0010A land/stencil dimensions. TI ADS1115 datasheet, same nominal DGS land pattern.
  • TI TPS3700 datasheet, page21 4218552-3/A,05/13, visually inspected: six0.60×1.10 lands,2.70 row centres,0.95 pitch, mask0.07 all around,0.127mm stencil. Page22 is DSE/WSON and was not used for these DDC parts.

    commentFileId-c67f0c72fa79023e6f62dfb5be243775d1a7aeacc768dd5a9c05c0fe43024561

    Retained DDC drawing.
  • 2102031704_JST-S2B-PH-SM4-TB-LF-SN_C295747.pdf, page1 component-side SM4 side-entry pattern.

    commentFileId-ffc67d1ffb8262d76f087903db72f925f355e4321d4f98e607c3970888781a51

    Retained detail. Tab outer edge=−2.93−3.40/2=−4.63; contact near edge=2.77−3.80/2=0.87; setback=5.50≤5.50max. Overall land span=2.77+1.90−(−4.63)=9.30≥9min. Lateral tab-inner-edge to adjacent contact centre=3.35−0.75−1.00=1.60; tab1.50×3.40 matches guideline. Warning / adjacent-part handoff: J1 uses the same original library geometry and may need the same 0.16mm contact alignment correction; J1 was outside this expanded assignment and was not edited.
  • C2758511.pdf, Feb2025, pages1/4/5: exact SMB identity, package limits, polarity and ordering.

    commentFileId-d7192bc023e1a1d87a2d9652a2613ffb0d629708b6f9a6c096f166a274c3f234

    Pinning evidence. Nominal open-source comparison: retained KiCad10 D_SMB reference, SHA256 e25e9f4acef5b55585afebc48c685e151fd0d2f33a5c3c61f9fdf0389e19ae67; this supports nominal layout, not independent tolerance/thermal qualification.
  • 2304140030_Diodes-Incorporated-SMCJ33CA-13-F_C135163.pdf, page5 suggested pad layout C6.90,G4.40,X2.50,X1=9.40,Y3.30mm; actual D14 gap3.83 and span9.89 provide enlarged pads without bridging.
  • 1806121749_Diodes-Incorporated-BAT54WS-7-F_C124205.pdf, page1 band=cathode and page4 pad layout G1.520,X0.590,X1=2.700,Y0.450.

    commentFileId-767ca8ea8436ced10a7099be1550218dba7a9db50307fea770a70bd096fa5755

    Inspected pad drawing. Actual D15 gap1.34mm remains generous. Assembly instruction: place cathode band toward project pad1/VSENSE_BUS; retain this in assembly polarity review. Numeric labels alone must not replace that physical marking.
Verification and finite release gates
Read-only native tree covered all83 pads across the12 expanded-scope instances after mutation. Independently reparsed the UNROUTED diagnostic KiCad snapshot with KiCad10.0.7: pad counts, sizes, row coordinates and key net names match the final table; size/count assertions passed. Expanded export readback. U9 remains EXP_RTN and U17 remains USB_RTN in exported EP/RTN/OVP. KiCad warns about zero-sized anchors for custom pads; do not round-trip this diagnostic file as replacement native copper. U9 Gerber behavior was already verified in the stable batch; new expanded-part final Gerber qualification has not been performed.
Native mask/paste readback separately checked U17, U22, U18 and J10: corrected perimeter/contact openings follow the lands; U22 mask0.40×1.55/paste0.30×1.45; U18 local mask0.74×1.24/paste0.60×1.10; J10 four matching land apertures; U17 perimeter mask0.70×0.34/paste0.60×0.24. U17 EP paste is visibly continuous, not six windows. Native selected checks at 2026-10-22T16:26:42Z: Overlapping Copper, Invalid Layer, Missing Footprints and No-Connect Violation Success, zero errors; U7 Invalid Pads remains Informational. No cosmetic or hole-type U7 changes were attempted after the procurement warning.
Error / final stencil gate: apply the exact six-window U9 procedure in the next section to each of U9 and U17, using separate final placement transforms and retaining their independent nets. Final top-paste must contain six isolated EP islands per device, not a full EP under the windows. Other copper/mask/drill/perimeter apertures must remain unchanged. Native implementation was not retried; final-file execution is unattempted until the board is frozen/routed. Exact example corner radius alone is not a separate hard release blocker when an assembler-approved nominal alternative is documented; segmentation/coverage still requires disposition.
Warnings retained: J2 locator PTH/zero-annular-ring disposition and shell solder-process qualification from the stable batch; J1 analogous contact-setback follow-up; normal final assembly polarity/stencil DFM. Overall placement, routing, thermal verification, full-board DRC and procurement release are not certified here.
New project-local rulesets: U17 perimeter bee4823e…,8e225834…; shared U9/U17 EP selector 50e5a005… (U9 geometry unchanged); U22/U23 lands/rows ca1d57c4…,c465bcaf…,83439ee3…; U18/U19/U20 lands/rows/pitch 9c14821c…,835683eb…,a0859f50…,80c89847…,849f13d8…; J10 contacts 4116b184…. No new parts/nets or pad identities were created or deleted.
Stable-footprint closure — 2026-10-22
This bounded section supersedes earlier open dispositions for U7, U9, J2, J5 and J7 only. It is not manufacturing release approval. Circuit work, U4, U15 and later parts, board outline, placement, routing, part identities and net mutations were outside this writer's scope. No completed copper repair was repeated or undone.

Table


Assigned itemStatusEvidence / remaining action
U7 nominal footprint retentionCompletedAll 32 exported pads remain 0.70 × 1.80 mm; native paste readback retains R0.175, 1:1 openings, rows at ±7.40 mm and existing pin orientation. Official KiCad nominal baseline accepted for engineering layout. Manufacturer revision applicability remains advisory; no further datum loop required.
U9 copper and EXP_RTN retentionCompletedNative PAD/RTN/OVP effective net remains 718fbc2f-c70e-484e-b7f3-287d0a315ce7; diagnostic KiCad identifies EXP_RTN. GND remains separate. Actual copper Gerber contains the repaired custom EP region, 1.65 × 3.40 mm outer bounding box, and ten 0.60 × 0.24 mm perimeter lands.
U9 native six-window pasteFailed to demonstrate a safe supported native implementationNo rejected paste-layer mutation was retried. Source asset inspection and rule definitions did not establish an independent paste-only layer/import path that preserves existing component-owned pad bindings. Asset replacement/import was unattempted, rather than risking the completed copper and terminal mapping. Native and Gerber paste still contain one continuous EP region.
U9 final export correction specificationCompletedExact six-window, transform and acceptance requirements below. Execution on the final routed export is unattempted and remains a stencil-release gate. No corrected production stencil is claimed.
J2 inactive duplicate ambiguityCompleted — absent from actual exportsDiagnostic Gerber/Excellon contains exactly four shell slots, two locating holes and no three inactive shell-node duplicates. The drawing discrepancy in layout_2d was not a duplicate physical hole. No duplicate deletion or drill deduplication is required.
J2 locating-hole stencil pasteCompleted — native correctionActual initial paste Gerber had two Ø0.60 mm flashes over locating holes. One two-node selector ruleset suppresses those nonsoldered locating-hole apertures. Re-export proves both are gone, with copper/drill/mask retained.
J5 / J7 repaired tabsCompleted — retainedEach exported footprint has eight 0.60 × 1.55 mm contacts and two 1.20 × 1.80 mm tabs. Native tab positions ±4.80, −1.935 mm and matching paste openings read back.
Full manufacturing qualification / final production exportUnattemptedUnrouted board; concurrent circuit writer active. These diagnostic snapshots must not be ordered.
Exact native change and layout handoff
Only one native ruleset was added: J2 locating holes no stencil paste, UID 863d3171-b7f7-4179-b2a4-c59c213cf050, setting solderPasteMaskExpansion = -0.31mm !important on exactly these two component-owned nodes:
  • 68ca8427-aace-4956-bdc8-36480bd9bf57__d5150ac1-7fac-4e9b-8ed4-ab4b4aff04b8.defaultFootprint.mounts.a77877e08178fc1a3b0e726bd7c2549e
  • 68ca8427-aace-4956-bdc8-36480bd9bf57__d5150ac1-7fac-4e9b-8ed4-ab4b4aff04b8.defaultFootprint.mounts.394588911379d6b6624272c8e38cd8bf
Rule-source readback confirms the value wins on both nodes; their position remains x±2.89, y1.21 mm, size/drill Ø0.60 mm. Negative expansion extinguishes these apertures; it does not resize copper or drill. Retain this rule through layout. No new placement, edge, clearance, routing or net constraints were added. Preserve existing repaired U7/U9/J2/J5/J7 selector overrides and pad UIDs. Existing J2 drawing-relative board-edge target remains local y−4.58 mm, insertion toward −Y; this is a handoff reference, not a newly enforced edge rule.
U9 exact final stencil postprocess requirements
Artifact requiring modification: the final top-paste Gerber, currently named esp32-lorawan-can-battery-monitor-f_paste.gbr, inside the final fabrication/stencil ZIP. Identify by TF.FileFunction,Paste,Top, not filename alone. Do not change top copper, masks, drills, bottom paste, netlist or placement files. If the assembler uses ODB++/IPC-2581 or generates its own stencil from copper, provide the same six-window specification and obtain written acceptance; a corrected Gerber is ineffective if the assembler ignores it.
Use the retained repaired EP centre as local (0,0), in the component-side X-right/Y-up orientation of this review. Replace all and only the continuous U9 EP paste image with six isolated rounded rectangles:

Table


WindowCentre x (mm)Centre y (mm)Width × height (mm)Corner radius (mm)
Main upper0+0.631.50 × 1.060.05
Main lower0−0.631.50 × 1.060.05
Prong upper left−0.25+1.530.25 × 0.340.05
Prong upper right+0.25+1.530.25 × 0.340.05
Prong lower left−0.25−1.530.25 × 0.340.05
Prong lower right+0.25−1.530.25 × 0.340.05
These graphical dimensions and R0.05 typical were visually rechecked on TI DRC0010J drawing 4218878/B, 07/2018, current downloaded PDF page45. Automated claim-level citation support for the graphical dimensions remains unverified; the image is the retained visual evidence, not an invented machine citation. TI explicitly specifies a 0.125 mm stencil and nominal 80% printed EP coverage.

u9-stencil-current

Release-processing acceptance checklist:
  1. Freeze the final board revision and export together; archive original files and their SHA-256 hashes. Resolve U9 by designator and EP terminal, not a remembered coordinate or aperture number.
  2. Derive the component-to-Gerber rigid transform from the final board/placement data and at least three noncollinear known U9 perimeter pad centres. Check side, units, handedness and rotation. Apply that transform to every window and its arcs. Do not infer Gerber Y sign from screen appearance.
  3. At the transformed EP location, identify the full continuous EP paste region and any coincident duplicate flashes. Remove only that image; abort on ambiguous ownership or overlap with another component. Do not add six windows on top of existing full paste, and do not globally alter a shared aperture definition.
  4. Insert the six positive, isolated R0.05 windows. Leave all ten perimeter apertures exactly unchanged. Do not rely on polarity clearing that could erase unrelated paste.
  5. Reparse and render the corrected file. Require exactly six EP islands, 0.20 mm vertical web between the main windows, 0.20 mm between each main/prong pair, and 0.25 mm horizontal web between each pair of prongs. Nominal total rounded opening area is 3.50712389 mm² (3.52 mm² before corner rounding); this is a dimensional check, not a command to rescale to an exact percentage.
  6. Compare corrected/uncorrected paste by geometric symmetric difference: zero difference outside the U9 EP region; perimeter paste unchanged; copper/mask/drill files byte-identical. Confirm apertures fit the EP copper. Validate both native and final exported checks and obtain stencil/assembly DFM acceptance.
  7. Repackage the corrected paste as the sole authoritative top-stencil file, label its revision, and prevent the assembler from using the uncorrected native stencil. Repeat after every new export or placement change.
No fixed export-origin assumption is safe: between this task's two diagnostic exports, the tagged contact/drill data shifted +8.04 mm in exported X while the scoped local geometry remained unchanged. The first snapshot U9 EP Gerber centre was (243.6244, −118.6250) mm; the second was (251.6644, −118.6250) mm. These are diagnostic evidence only, not final processing coordinates.
J2 actual export findings
Both exports contain four shell slots: two 0.60 × 1.70 mm and two 0.60 × 1.40 mm, at local x±4.325 mm and y+1.71/−2.47 mm. Excellon uses a Ø0.60 tool with 1.10 and 0.80 mm routed centreline lengths respectively, yielding those total slot lengths. No Ø0.80 legacy shell drill exists. Actual top/bottom copper shows four corrected shell lands, not seven. Coincident same-net power/GND contact flashes remain intentionally duplicated as commands but have identical geometry: sixteen terminal-bound contact flashes resolve to twelve physical contact lands. They neither enlarge a land nor double a stencil thickness and must not be removed by deleting terminals.
The second export has 20 J2 paste commands: sixteen contacts (twelve unique contact images) plus four shell apertures, versus 22 before correction. The two locating-hole paste flashes are absent. Top copper remains 22 commands and bottom copper six, including the two locating-hole discs; masks/drills are unchanged locally.
Warning — separate from the closed duplicate issue: the original J2 library source labels its two unnumbered locating holes thru_hole, and the actual exported Excellon marks their Ø0.60 tool as Plated/PTH, with copper discs equal to hole diameter (no nominal annular ring). This classification was not changed because the task required retaining corrected copper/slots and there is no verified purchased-stock plating requirement. Before fabrication, obtain the fabricator's disposition of these mechanical locating holes: approved finished Ø0.60 plated mechanical holes, or a documented NPTH correction with appropriate copper clearance. Do not silently relabel the shared Ø0.60 tool NPTH: the same tool also cuts the four plated shell slots. If an export-only NPTH correction is selected, split the two round locator hits into a separate NPTH drill artifact and verify copper clearance; shell slots must remain PTH. This is a specific DFM action, not evidence of duplicate drills.
Warning: four shell paste apertures remain. Confirm whether the assembler uses pin-in-paste/reflow for these shell stakes or selective/hand soldering, and qualify shell paste volume accordingly. No unsupported shell stencil volume was invented here. Purchased-stock applicability of the retained HRO 2020-12-08 drawing remains a revision caveat, not a reason to revert the repaired geometry.
Finite severity and verification
  • Error / stencil release gate: unsegmented U9 EP paste still exists natively and in the diagnostic Gerber. Implement the exact final-file correction above or obtain a documented assembler-approved alternative before stencil manufacture. This does not block preserving and placing the corrected copper footprint.
  • Warnings: J2 locating-hole plating/zero-annular-ring DFM disposition; J2 shell solder process; stock/drawing revision applicability. These are distinct from the duplicate-hole ambiguity, which is closed.
  • Info: U7 Invalid Pads remains informational; do not change hole type to silence it. Official KiCad nominal baseline is accepted. U9 KiCad import warns about a zero-size anchor pad; actual Gerber has a valid full custom EP region and an approximately 0.00092 mm redundant copper anchor flash entirely inside it, not a missing EP. Do not round-trip that anchor as replacement copper.
  • Native checks at 2026-10-22T16:09:54Z: Overlapping Copper, Invalid Layer, Missing Footprints and No-Connect Violation all Success, zero errors in these selected checks. U7 Invalid Pads Informational. Airwires are Error on the unrouted board; full manufacturing, full-board external DRC, paste DFM and assembly approval were not run.
  • Scoped before/after export comparison passed: object-type/local-bounding-box multisets for U7/U9/J2/J5/J7 top copper, bottom copper, top mask and top paste were unchanged except removal of the two intended J2 locator paste circles. This is a scoped geometry check, not a whole-board checksum, full polygon equivalence proof or final assembly validation. Tool versions: KiCad 10.0.7; Gerbonara 1.6.3.
Diagnostic evidence only — UNROUTED / DO NOT ORDER: first Gerber snapshot, first KiCad snapshot, after-locator-paste Gerber snapshot.
The assigned closure batch is complete with the explicitly failed native-paste implementation and deferred final-artifact execution above; overall layout and manufacturing completion are not claimed.
Follow-up disposition — 2026-10-20
This section supersedes the historical batch dispositions below. This bounded follow-up is complete, but stencil and manufacturing release are NOT complete. Only local footprint geometry was changed; no schematic, terminal binding, part identity, placement, routing, outline or manufacturing-profile changes were made.

Table


Assigned itemFollow-up outcomeRemaining blocker / qualification
U4 independent rounded EP pasteFailed — supported mutation path not demonstrated. Earlier copper and 1.55-square paste retained.Exact independent R0.05 aperture needs supported paste-only implementation or assembler acceptance of existing square corners.
U9 copper repairCompleted. Ten perimeter lands and custom EP copper corrected; read back in tree and copper SVG.Does not close stencil qualification.
U9 segmented EP pasteFailed — supported mutation path not demonstrated. Full continuous custom-shape paste remains.Six separate apertures must be implemented/verified or an alternative approved by assembly engineering before release.
U7 pad repairCompleted to official KiCad nominal CAD. All 32 lands resized/repositioned; mask and paste read back.Manufacturer drawing/CAD side-normal interpretation and assembly stencil acceptance are not certified by this CAD match. Informational Invalid Pads remains.
J2 drawing reconciliation and geometryCompleted against visually inspected HRO 2020-12-08 pattern, replacing the older 2015 reference target; same MPN retained. Copper and drill readback completed.Purchased-stock revision, slot manufacture, and inactive duplicate-node Gerber/drill behavior still need release verification.
U13 PW0014ACompleted. Same verified correction as U11, all 14 lands and effective net IDs read back.No new local blocker.
U12 and U14 DBZ0003ACompleted. Six lands corrected and orientation retained; copper-size mask/paste geometry and effective nets inspected.No new local geometry blocker; automated citation validation of the visually inspected stencil detail remained unavailable.
U11, J5, J7Completed in preceding batch; retained.No additional edits attempted in this follow-up.
Fabrication export, assembly approval, full PCB completionUnattempted, outside this batch.PCB remains unrouted and not manufacturing-ready.
Final live geometry and evidence
All dimensions in this section are measured live implementation values, in millimetres, rather than a claim of independent fabrication qualification.
  • U9: perimeter 0.60 × 0.24, R0.05, x = ±1.40, pitch 0.50. EP body spans x±0.825 and y±1.20; four 0.25-wide prongs at x±0.25 extend to y±1.70, with rounded outer tips. Copper SVG confirms the actual custom outline; the generic computed size field is not its bounding box. EP, RTN and OVP retain net UID 718fbc2f-c70e-484e-b7f3-287d0a315ce7 (EXP_RTN); GND remains the separate 7bbe76d5-294c-4c12-87f0-7337e3143ddc. Final paste SVG explicitly shows the continuous EP outline, not six windows. Earlier TI target and validated stencil citation remain in the historical U9 section below.
  • U7: adopted official KiCad RAK3172 nominal footprint at pinned commit, transformed into the existing pin orientation. All 32 pads are 0.70 × 1.80 with R0.175; top/bottom rows y±7.40, side rows x±7.40. Top x runs −5.25 through +5.75 at 1.00 pitch; bottom retains its pin gap. Side pads retain their 270° rotation. All 32 mask/paste openings read back 1:1 with zero expansion. This replaces the previously unresolved implementation datum with a concrete CAD datum; it does not assert that every interpretation of the manufacturer's graphical body drawing is identical.
  • J2: the newly inspected same-MPN drawing is dated 2020-12-08, not 2015. Its visual evidence, rather than the older KiCad HRO geometry, governs this implementation.

    commentFileId-0fcef6edb260eec13544eb4d345c8931775b8ff125cb2ec075e8a2111e939635

    Retained component-side drawing detail. Automated claim-level citation validation for this new graphic was not obtained; source-revision applicability to purchased stock remains unverified. Final live eight small contacts are 0.30 × 1.14 and four merged power/GND lands 0.60 × 1.14, all y=2.28; merged centres x±2.40 and ±3.20. Each merged land retains both original same-net terminal-bound pads coincident, so neither terminal was orphaned. Shell centres x±4.325, y=1.71 and −2.47; rear copper/slot 0.90 × 2.00 / 0.60 × 1.70, front 0.90 × 1.70 / 0.60 × 1.40. Locating holes Ø0.60 at x±2.89, y1.21. Native SVG confirms these active-node drill dimensions. Contact mask/paste expansion is zero. Datum is the unchanged locating row; component-side Top view and insertion toward −Y are retained. The drawing-relative board-edge target is local y−4.58; board placement/edge was not changed.
  • U13: 14 pads 0.45 × 1.50, R0.05, 0.65 pitch, y±2.90; paste 1:1 and mask +0.05 per side. Same TI PW0014A reference as U11.
  • U12/U14: effective lands 1.30 × 0.60, R0.05; pin1 GND at (1.05,−0.95), pin2 RESET at (1.05,0.95), pin3 VDD at (−1.05,0). U12's original −90° pad rotations are preserved using local size 0.60 × 1.30. Final mask opening is 1.40 × 0.70; paste is 1.30 × 0.60. Original TI DBZ0003A drawings were visually inspected:

    commentFileId-b0b2ac33856dd14e9973024cd9a3cf861aa50a1c4bea3027994c1f02d34ed6a5

    board pattern,

    commentFileId-768a3fa2b0286e97654bfeecfd16047ec55b3e8895604faf9c9c6136c8dd91a8

    stencil pattern. These links preserve the inspected graphical evidence; they are not substituted automated citation validation. U12 RESET remains VBUS_OK and VDD remains VBUS; U14 RESET remains SENSE_EN and VDD remains 3V3.
Tool limitations and final checks
Independent paste-only mutation was attempted, but Top Solder Paste was rejected as a supported pad/shape layer in the exercised native path. Seven temporary paste-test rectangles were disabled after deletion was rejected; they are not active stencil apertures. Do not infer a universal platform limitation or count them as a completed stencil repair.
Read-only checks at 2026-10-20T08:37:18Z: Overlapping Copper, Invalid Layer, Missing Footprints and No-Connect Violation all Success, zero selected-check errors. Component Overrides reports 12 Warnings reflecting deliberate local overrides; U7 Invalid Pads remains Informational, not an Error. No pad-hole type override was used to silence that finding. Airwires and full manufacturing review remain outside this local check pass.
Final readbacks additionally confirmed all 31 pads across U9/U12/U13/U14, all 32 U7 mask/paste openings, and J2 active copper/drill geometry and terminal-net associations. Three old J2 duplicate shell nodes are tree-inactive but still drawn by layout_2d; actual export behavior remains unverified. Do not mistake that inspection rendering for proof of physical duplicate holes. Attempts to submit follow-up tool feedback failed; no new feedback ticket is claimed.
Follow-up rulesets are project-local and named U7..., U9..., J2 HRO 2020..., U13 TI..., and U12/U14 TI DBZ.... Historical ten-ruleset accounting below applies only to the preceding batch. The current repair is intentionally not represented as a fresh library-part release.

Historical initial batch (retained for traceability)
2026-10-20 — bounded footprint-only batch. Not manufacturing release approval.
Scope and disposition
Reviewed U4, U7, U9, U11, J2, J5 and J7 against live footprint geometry, library identity and manufacturer drawings. Original graphical drawings were downloaded and visually inspected where text extraction omitted dimensions; missing extracted text was not treated as missing evidence. All dimensions below are millimetres, in each footprint's local orientation unless stated otherwise. Manufacturer examples/guidelines are reference patterns, not proof that every alternative pattern is unmanufacturable.

Table


ItemReviewMutation / disposition
U4 BQ24075RGTRCompletedCompleted: nominal copper, mask and paste-size correction. Unattempted: independent exposed-pad paste corner-radius refinement; exact stencil-example compliance remains open.
U11 TMUX1511PWRCompletedCompleted: all 14 lands and row positions corrected and read back.
J5 SM08B-SRSS-TB(LF)(SN)CompletedCompleted: two reinforcement lands corrected; signal lands retained.
J7 SM08B-SRSS-TB(LF)(SN)CompletedCompleted: same correction as J5.
U7 RAK3172-T-9-SM-ICompleted comparison; full geometry qualification failedUnattempted repair: unresolved side-pad normal-offset/body-datum reconciliation. Unchanged; quality report filed.
U9 TPS26621DRCRCompleted comparison; reference-pattern qualification failedUnattempted repair: full custom-copper and segmented-stencil repair not demonstrated in this bounded pass. Unchanged; exact repair specified below and quality report filed.
J2 TYPE-C-31-M-12, C165948Completed comparison; current-revision qualification failedUnattempted repair: retrieved manufacturer drawing revision not reconciled with current stock; latest attached LCSC URL returned HTML. Unchanged; quality report filed.
The assigned inspection/correction/report batch is complete; the unresolved footprint qualifications and the overall PCB design are not complete.
Measured versus manufacturer reference
U4 — BQ24075RGTR, RGT0016C
Source identity: TI BQ24075 datasheet, package drawing 4222419/E, 07/2025, downloaded PDF pages 53–54.

commentFileId-ea75f40138dc6db53d2f4d290dd4ea631e00f827128d92718f11e224875c63ea

Inspected land-pattern image.

Table


FeatureFinal live geometryManufacturer example / conclusion
Perimeter pads 1–160.24 × 0.60, corner R0.05Matches nominal land example
Pitch0.50Matches
Opposing pad centres2.80; radial positions ±1.40Matches
EP17, GND1.68 × 1.68 centred at 0,0Matches nominal copper example
Mask+0.05 per side; EP opening 1.78 × 1.78NSMD implementation; verified in live SVG
Perimeter pasteSame nominal size as copper, R0.05Verified live
EP paste1.55 × 1.55, inset −0.065 per sideNominal size/approximately 85% area matches example; actual live aperture corners are square, not example R0.05
The source recommends a 0.125-mm stencil and 85% EP paste coverage. Thermal vias are optional and, when used, should be filled, plugged or tented as appropriate.
Warning / remaining action: obtain assembler acceptance of the square-corner EP aperture or implement an independently rounded 1.55-mm aperture. Do not claim the stencil is an exact drawing match. Thermal-via selection and thermal performance were not assessed or changed.
U11 — TMUX1511PWR, PW0014A
Source identity: TI TMUX1511 datasheet, drawing 4220202/B, 12/2023, downloaded PDF page 43.

commentFileId-29e28b5464546df2fa5743694aec259992282d7c2e6a958fc36d338ec6f11dd7

Inspected pattern image.

Table


FeatureFinal liveManufacturer example
Pads 1–140.45 × 1.50, R0.050.45 × 1.50
Pitch0.650.65
Opposing row centres5.80, y = ±2.905.80
Mask opening0.55 × 1.60+0.05 per side implementation
Paste opening0.45 × 1.50, R0.05Nominal 1:1 pattern
Pad size, pitch and row spacing are also confirmed by the datasheet query. All 14 pads and their effective net IDs were read back; pad order/orientation was preserved.
J5 and J7 — JST SM08B-SRSS-TB(LF)(SN)
Source identity: JST SR/SZ manufacturer catalog. The manufacturer host returned 403 on the computer; the same manufacturer drawing was obtained from the 2304140030_JST-SM08B-SRSS-TB-LF-SN_C160407.pdf.

commentFileId-9a8c3c1942be3c07df839fd1e0089893066aec51a91a76ecdcbf70ed68ea31c4

Inspected side-entry layout detail.

Table


FeatureBeforeFinal live / guideline
Eight signal lands0.60 × 1.55, 1.00 pitchRetained; matches nominal guideline
Reinforcement pads 9,101.50 × 2.001.20 × 1.80
Reinforcement x centres±4.80Retained
Reinforcement y centre−1.940−1.935, relative to unchanged signal row y=1.940
Mask/paste expansion0Retained; SVG shows matching copper-size openings
Relative tab-centre calculation: 1.940 + 1.55/2 − 5.55 + 1.80/2 = −1.935. This applies the drawing's overall land span while retaining existing signal positions. The source identifies an SMT eight-circuit side-entry part and states component-side view, noncumulative centre tolerance ±0.05 and guideline status.
Pads 9 and 10 remain electrically unconnected. No mechanical drill was added. Mask/paste were inspected, but no independent JST stencil-thickness qualification was obtained.
U7 — RAK3172-T-9-SM-I
Source identity: RAK official datasheet, explicitly covering RAK3172 and RAK3172-T and including the exact ordering variant. Manufacturer

pad_layout

pad layout and

mechanical_dimension

mechanical drawing were visually inspected. Retained images:

commentFileId-35982a4781266689f8aedfbb4ac080576d33142fab22d895460119a50d593b62

pad layout,

commentFileId-496f35c3908c5ddc6025230f7c61d4eef701eb3799c8205626a105820f5b27be

body.

Table


FeatureLive, unchangedReference / qualification
32 pads0.80 × 1.80Drawing nominal 0.70 × 1.80
Pitch1.00Matches nominal
Top/bottom row y±7.288Drawing-derived nominal ±7.40 in present orientation
Top-row x span−5.32 … +5.68Body/drawing-derived −5.25 … +5.75
Side-row x±7.569Unresolved normal-offset datum, not safely inferred from pitch alone
Mask/paste0 expansion, full rectangular copper-size openings on all32 padsInspected; no separately qualified stencil prescription
Pin ordering aligns with the official pin image after orientation transformation: live top-right pad1 UART2_RX; pad2 UART2_TX; top-left pad12 RF; left13–16; bottom17–19 then gap then20–24; right25–32. No pins were moved or rebound.
A concrete replacement candidate is the official KiCad RAK3172 footprint. It supplies complete coordinates, but its side-centre datum versus the RAK body drawing was not reconciled here. Next action: reconcile manufacturer body/land datum with that CAD pattern, then repair or replace all32 lands preserving pin numbers, verify mask/paste and regenerate the pad-type assessment. Do not blindly change hole types to silence the Informational Invalid Pads result.
U9 — TPS26621DRCR, DRC0010J
Source identity: TI TPS2662 datasheet, drawing 4218878/B, 07/2018, downloaded PDF pages44–45.

commentFileId-9d4d52e8bdb1f834bcf7d58a884ac30ad82dbbb23fd4fc64ea8052c4f8c96c01

Inspected copper drawing.

Table


FeatureLive, unchangedTI nominal example / repair target
Pads1–100.80 × 0.300.60 × 0.24, R0.05
Pitch0.500.50
Opposing row centres3.00, x±1.502.80, x±1.40
EP11 main body1.62 × 2.50, yoffset−0.011.65 × 2.40, centred
EP overall height including prongs3.523.40
EP prongsExisting custom shapeFour0.25-wide prongs, x centres±0.25, R0.05 pattern
EP pasteContinuous full custom shape, 0 insetTwo1.50 × 1.06 main windows plus four0.25 × 0.34 prong windows
TI states 0.125-mm stencil and 80% printed EP coverage. The main paste windows centre at y±0.63; prong paste windows at x±0.25, y±1.53, as visually dimensioned in the retained stencil image.
Repair specification: replace the existing EP custom copper with the DRC0010J outline; correct perimeter sizes/row centres; suppress the continuous EP paste and implement the six independent stencil apertures from the source. Verify aperture clearances, mask definition and all terminal bindings after repair. EP11 must remain EXP_RTN, not board GND. A safe segmented-paste implementation was not demonstrated in this pass; this is not a claim that the platform cannot implement it. Keep this footprint unqualified until repaired or an assembly engineer accepts a documented alternative.
J2 — HRO TYPE-C-31-M-12, LCSC C165948
Library identity search confirmed the exact MPN and C165948, despite the legacy display name “TYPE-C 16PIN 2MD.” Source inspected: HRO manufacturer drawing hosted by Huaqiu, 2015-05-13;

commentFileId-29e542efa9be976ea88b8ec2eea0105964fecb793a7e810a95ed44996c4bbae7

full retained drawing. The newer attached LCSC URL served HTML instead of a PDF.

Table


FeatureLive, unchangedRetrieved HRO drawing
Small contact landsSixteen0.30 × 1.30, adjacent same-net power/GND lands touchingTwelve physical lands: eight0.30 × 1.45 and four merged0.60 × 1.45
Merged power/GND centresSeparate terminal-bound padsx±2.45 and±3.25
Shell x centres±4.33±4.32
Shell row span4.184.18
Shell slots, longer pair0.80 × 1.700.60 × 1.70
Shell slots, shorter pair0.80 × 1.400.60 × 1.20
Shell copper, longer pair1.20 × 2.101.00 × 2.10
Shell copper, shorter pair1.20 × 1.801.00 × 1.60
Locating holesØ0.75 at x±2.90Ø0.65 at x±2.89
Next action: obtain the drawing applicable to purchased C165948 stock and compare its revision before resizing drills. If the retrieved drawing governs, implement the listed contact/slot/locating corrections while preserving USB D+/D−, CC, VBUS, GND and shell mappings. Merged power/GND geometry must not orphan either terminal. Three pre-existing inactive duplicate shell nodes appeared in the SVG despite tree active=false; check actual drill/Gerber output before asserting a duplicate physical hole. No duplicate node was deleted here. No current-revision assembly qualification is claimed.
Local changes and traceability
Only component-owned pad rules were changed, via ten project-local selector rulesets. Component placements, board outline, routing, part identities, schematic, terminal UIDs and net assignments were not edited. Manufacturing-profile rules were not changed.

Table


RulesetUIDScope
U4 TI RGT0016C pad geometryef6e9685-feab-47d0-9cd7-6eaf6933bc96All17 U4 pads: corner and mask only
U4 TI left row2.8mm38f07c24-30a1-493d-b76a-eeea7bc5ade1TS, BAT_1, BAT_2, ~CE
U4 TI right row2.8mm8f69a84d-d8fa-4b1b-a95d-4927b5e4e1bc~CHG, OUT_1, OUT_2, ILIM
U4 TI top row2.8mm0f7921aa-ecd9-45f6-9ae9-d8cc5f69d8c0ISET, SYSOFF, TMR, IN
U4 TI bottom row2.8mmbee36cd7-f7c7-4d1f-bba8-9135e54b922cEN2, EN1, ~PGOOD, VSS
U4 TI exposed pad and paste644b581b-e26e-49bb-9fe1-2b316ca29386EP17 size and paste inset
JST reinforcement lands8587f9bb-0936-44d4-9409-6aada72c8b28J5/J7 pads9,10 only
U11 TI PW0014A lands18e9832e-efed-47f9-9f38-e1283d52bf4eAll14 U11 lands
U11 TI pins1 through728610f06-5cc8-4db0-b0fd-19457f16d515Bottom row y−2.90
U11 TI pins8 through142a045e81-e5cf-4ed5-b7ab-69bfe6e6fd4bTop row y+2.90
Exact pad identity convention is component UID + __ + terminal UID. U4 component: bd9f82b7-6e86-4d67-897d-ed47f3fb4792; EP17 terminal: 80cd6337-6c66-4186-b16c-41eea87dc85a. U11 component: 74f1a6a8-3668-46a2-a745-b9c8deb8c9ca, pads1–14 retained. J5 component: beb8b6a3-7cf4-4563-b54f-a7715f1b0b98; J7 component: bcc39374-79ad-4160-9006-600b3b519495; pad9 terminal: d8b269f5-7197-41ec-b7a9-ab3e1abefc99; pad10 terminal: 42959fa1-c578-47c6-9b58-dc590320af5c. Full perimeter UID selectors are retained in the rulesets above.
An initial overlapping U4 common size rule incorrectly affected EP17. Readback detected it; the common size/paste rules were removed and perimeter-only size/paste rules moved to disjoint row selectors. Final live mask/paste SVG confirms the EP1.78-mm mask opening and1.55-mm paste opening, consistent with1.68-mm copper. This correction was verified, not merely inferred from mutation success.
Verification evidence and limits
  • Read all scoped live pad/element nodes and schematic pin mappings; read back51 pads of the four changed component instances.
  • Independently inspected final mask/paste SVG for U4, U11, J5 and J7, and all32 U7 openings. U9 and J2 geometry/paste were inspected during the initial comparison.
  • Preserved pad UIDs and effective net assignments in readback; no schematic mutations were performed. This is not a before/after whole-netlist checksum.
  • Fresh selected checks 2026-10-20T08:18:54Z: Overlapping Copper Success; Invalid Layer Success; Missing Footprints Success; No-Connect Violation Success. Zero errors in these selected checks.
  • Component Overrides: one Warning, U4 EP ruleset. This flags a deliberate override; it does not establish a short.
  • U7 Invalid Pads: Informational, not Error. Its generic message does not by itself establish a drill defect.
  • Airwires remain Error because the PCB is not routed. The earlier result total351 was a mixed/paginated check count, not a verified count of351 airwires.
  • No full placement, routing, thermal, paste-release, assembly-tolerance or fabrication-export qualification was performed. Inactive J2 shell-node export behavior remains unverified. Board dimensions and out-of-outline initial placement were not changed.
  • Part-quality reports were successfully filed for U7, U9 and J2 with exact library part UIDs and the source/repair caveats above.
Retained additional source evidence
The dimensions labelled visually inspected above were read from original graphical drawings, not invented machine-extraction citations. Source URLs identify the documents used; they do not imply independent current-stock revision qualification.

rak-pin

u9-stencil

j2-detail-full

  • Active charging-footprint repair — 2026-10-23

  • Verification evidence and severity

  • U25 exact repair handoff

  • Retained source evidence and local rules

  • Final adjacent DFM and sense-block verification — 2026-10-22

  • Sources, implementation and verification

  • Expanded new-part closure — 2026-10-22

  • Sources and derivation

  • Verification and finite release gates

  • Stable-footprint closure — 2026-10-22

  • Exact native change and layout handoff

  • U9 exact final stencil postprocess requirements

  • J2 actual export findings

  • Finite severity and verification

  • Follow-up disposition — 2026-10-20

  • Final live geometry and evidence

  • Tool limitations and final checks

  • Historical initial batch (retained for traceability)

  • Scope and disposition

  • Measured versus manufacturer reference

  • U4 — BQ24075RGTR, RGT0016C

  • U11 — TMUX1511PWR, PW0014A

  • J5 and J7 — JST SM08B-SRSS-TB(LF)(SN)

  • U7 — RAK3172-T-9-SM-I

  • U9 — TPS26621DRCR, DRC0010J

  • J2 — HRO TYPE-C-31-M-12, LCSC C165948

  • Local changes and traceability

  • Verification evidence and limits

  • Retained additional source evidence