Pocket_lock
auto-layout-0584140f-8b4f-4969-ba02-dd213280dc33 after adding ACUs.Waiting for input
Schematic is Auto-placed
The schematic has been arranged automatically. Flux can redraw it to be more readable, with components placed in related groups and wires drawn more legibly. This takes about 10-60 mins.
Table
| Rail | Continuous/typical | Peak/worst case |
|---|---|---|
| 5V motor | motor two-phase 0.926A (Rmin 10.8Ω) | 1.3A design allocation including horn/margin |
| 3V3 AO | HS6621 RX/TX ~6.6mA peak plus 3.4uA Halls; COSS TBD | 150mA regulator ceiling |
| Battery @3.6V | — | 5V rail 2.124A @85%; 3V3 allocation 0.162A @85%; total provisional 2.29A |
Key selections
Power budget
GPIO/PINMUX allocation
Reset/wake distinction
HS6621 pin audit
Evidence-gated items
ERC