Audit the 20 existing components against the specification and remove/replace incorrect parts.
Complete the schematic BOM: power protection, regulator support parts, relay drivers, light MOSFET/protection, battery ADC divider, ultrasonic interfaces, whisker input, connectors, and test points.
Wire all nets, including the exact J1/J2 assignments.
Finalize whisker sensing using the measured states: WHISKER_A relative to WHISKER_B is +5 VDC open and 0 V hit, with galvanic isolation maintained.
Run ERC and independent design review, correcting all actionable faults.
Verify the TE DTM13-12PC-12PD-R008 footprint orientation, cavity numbering, and mating-face mapping against the official customer drawing.
Start PCB layout only after schematic approval; then place, route, run DRC, and validate outdoor/high-current constraints.
Release fabrication files only after connector mapping, whisker bench loading, battery transients, lighting current, and ultrasonic sensor model/pinout are validated.
No project changes were made this turn. Execution cannot resume because your ACUs ran out.
I can’t see your ACU balance or renewal date. Check your Flux account’s usage/billing page for the reset date or purchase options; if it looks incorrect, contact Flux support at https://docs.flux.ai/Introduction/getting-support.
No project changes were made, and execution remains stopped because your ACUs ran out.
I can still help with text-only engineering guidance, such as reviewing requirements you paste here, planning tests, explaining circuits, or preparing measurement procedures.
I cannot inspect, edit, wire, or verify the Flux project until ACUs are available. The last confirmed state remains 20 components and 0 nets; execution stopped because your ACUs ran out.
LiftLink is an outdoor ESP32-based controller for a ShoreStation-style boat lift. It controls lift UP/DOWN, curtain OPEN/CLOSE, canopy lighting, monitors the existing upper-limit whisker circuit without interfering with it, measures battery voltage, and interfaces with two waterproof 5 V ultrasonic sensors.
Intended Use
Installed outdoors on a 12 V or 24 V nominal boat-lift battery system near motors, relays, long cables, moisture, and electrical transients. This is a prototype/validation design and is not approved for fabrication until all pre-production validation gates are closed.
What the Device Should Do
Provide four isolated dry-contact outputs emulating existing ShoreStation controls.
Control battery-powered canopy lights through a protected low-side MOSFET.
Monitor the existing two-wire whisker switch through a galvanically isolated, high-impedance input.
Measure battery voltage on ESP32 ADC1 GPIO34.
Power and read two 5 V waterproof ultrasonic sensors.
Support ESP32 manual boot/reset and a six-pin UART programming header.
Main Features
ESP32-WROOM-32UE-N16 Wi-Fi/BLE module.
12/24 V nominal battery input with reverse-polarity, overcurrent, surge, and EMI protection.
LMR33620 buck regulator producing +5V_SYS.
TLV76733 LDO producing +3V3_SYS.
ULN2803A relay-coil driver and four 5 V relays.
Two 12-position right-angle Deutsch-family external connectors.
Test points for BATTERY_POS, GND, +5V_SYS, +3V3_SYS, BATTERY_ADC, and WHISKER_GPIO.
ESP32 antenna keepout applies on every copper layer and to components/enclosure obstructions.
Relay Outputs
Four 5 V relay coils driven low-side by ULN2803A.
ULN2803A COM connects to +5V_SYS for internal flyback diodes.
Relay contacts remain electrically separate from LiftLink logic and emulate the ShoreStation switches.
Isolated Whisker Input
WHISKER_A and WHISKER_B remain isolated from LiftLink GND and all logic rails.
Optocoupler LED input network connects only across WHISKER_A/B.
Field measurement with the original ShoreStation controller powered normally: open/not-hit = approximately +5.0 VDC from WHISKER_A to WHISKER_B; hit/closed = approximately 0.0 VDC. WHISKER_A is the positive side in the open state.
Use Vishay VOM617A-8X001T or a validated equivalent whose minimum CTR is specified at 1 mA input current.
Nominal input network: 3.3 kOhm series resistor from WHISKER_A to the optocoupler anode, optocoupler cathode to WHISKER_B, and an antiparallel diode across the optocoupler LED for reverse-voltage protection. At 5.0 V and approximately 1.2 V LED drop, nominal LED current is approximately 1.15 mA.
Maintain creepage/clearance and copper separation across the isolation barrier; no logic-ground copper may enter the whisker-side isolation region.
Logic side: collector to WHISKER_GPIO, emitter to GND, 10 kOhm pull-up to +3V3_SYS, 100 nF to GND.
Logic interpretation: open/not-hit drives WHISKER_GPIO low; hit/closed releases it high after RC filtering.
Retain a schematic note recording the measured condition: FIELD VERIFIED: OPEN = +5 VDC A-TO-B; HIT = 0 VDC. WHISKER INPUT MUST REMAIN GALVANICALLY ISOLATED.
Battery ADC
GPIO34 (ADC1) dedicated to battery measurement.
Divider and clamps must be sized against maximum charging and protected transient voltage, not nominal battery voltage.
Proposed 150 kOhm / 10 kOhm divider is provisional until worst-case input limits are established.
Ultrasonic Interfaces
Sensors powered from +5V_SYS with local 100 nF bypass.
Trigger outputs: GPIO32 and GPIO25.
PWM returns level shifted to 3.3 V using resistor dividers: GPIO33 and GPIO26.
Canopy Light Output
BATTERY_POS feeds LIGHTS_POS through dedicated circuit protection.
LIGHTS_NEG switches through a 3.3 V logic-level N-channel MOSFET to GND.
MOSFET voltage, current, thermal design, fuse, and copper width remain dependent on measured/nameplate light current.
Interfaces and Connections
J1 Main Lift/Power — C-Key Bank of DTM13-12PC-12PD-R008
BATTERY_POS
BATTERY_NEG
LIFT_COMMON
LIFT_UP_SIGNAL
LIFT_DOWN_SIGNAL
CURTAIN_COMMON
CURTAIN_OPEN_SIGNAL
CURTAIN_CLOSE_SIGNAL
LIGHTS_POS
LIGHTS_NEG
WHISKER_A
WHISKER_B
J2 Sensors — D-Key Bank of DTM13-12PC-12PD-R008
HEIGHT1_5V
HEIGHT1_GND
HEIGHT1_DATA/TRIGGER
HEIGHT1_PWM
HEIGHT2_5V
HEIGHT2_GND
HEIGHT2_DATA/TRIGGER
HEIGHT2_PWM
SPARE1
SPARE2
SPARE3
SPARE4
External Connector Definition
Use one TE Connectivity / DEUTSCH DTM13-12PC-12PD-R008 right-angle, through-hole, 24-position combined header.
Treat the C-key 12-position module as schematic bank J1 and the D-key 12-position module as schematic bank J2; each bank retains cavity numbering 1 through 12.
Manufacturer data confirms two 12-position, two-row modules with 4.19 mm contact pitch; the individual-module mating-face convention is upper row 1–6 and lower row 12–7.
The exact combined C/D module orientation, board-hole coordinates, mounting features, and PCB-view-to-mating-face mapping are not locked. No production footprint may be approved from inferred geometry.
Firmware-Relevant Hardware Requirements
Use only safe non-flash GPIOs for outputs.
Avoid GPIO12 and other boot-strapping conflicts.
GPIO34 is input-only and ADC1-compatible with Wi-Fi.
Relay commands must default inactive during reset/boot.
Firmware must interlock opposing relay commands so UP/DOWN and OPEN/CLOSE cannot energize simultaneously.
Wide copper for battery and light paths; relay contacts separated from low-voltage logic.
Short regulator power loops and local capacitors.
Keep noisy relay/light currents away from RF and sensing circuits.
Outdoor enclosure, condensation protection, conformal coating, and connector sealing to be addressed at system level.
Important Design Decisions
Relay dry contacts provide isolation for ShoreStation command signals.
Existing whisker circuit is never referenced to LiftLink ground.
Whisker voltage/polarity field validation is complete; the isolated circuit values must still be confirmed by schematic review and bench test before release.
No manufacturing files or ordering until the schematic is validated and field-dependent values are resolved.
Assumptions
Battery system may reach charging voltages above 24 V nominal; exact steady-state maximum and transient environment are not yet supplied.
Maximum canopy-light current is not yet supplied.
Exact waterproof ultrasonic sensor model and timing/electrical behavior are not yet supplied.
Connector MPN is fixed as TE Connectivity DTM13-12PC-12PD-R008; the exact combined assembly footprint, C/D bank orientation, cavity numbering view, and PCB-to-mating-face mapping still require verification against the official combined customer drawing or manufacturer CAD.
ShoreStation whisker field voltage and polarity are measured: open/not-hit is approximately +5.0 VDC from A to B and hit/closed is approximately 0.0 VDC. Source impedance has not been directly measured; bench validation must confirm the approximately 1.15 mA optocoupler load does not disturb the original controller.
Required Pre-Production Validation Items
WHISKER FIELD MEASUREMENT COMPLETE: open/not-hit is approximately +5.0 VDC A-to-B; hit/closed is approximately 0.0 VDC. Before release, bench-test the finalized 3.3 kOhm + VOM617A-8X001T input network on the real controller and confirm it does not alter controller behavior.
Confirm battery minimum, maximum charging voltage, and expected transient/load-dump profile.
Confirm canopy-light maximum continuous/inrush current and cable fuse requirement.
HARD RELEASE HOLD: verify the DTM13-12PC-12PD-R008 footprint orientation, C-key/D-key bank placement, cavity numbering, mounting geometry, and mating-face pin mapping against the official TE combined mechanical drawing or manufacturer CAD before PCB release.
Bench-test relay interlocks and power-up default state.
Verify RF keepout in final board and enclosure.
Manufacturing and Assembly Expectations
Production-intent SMD PCB assembled by a standard PCB assembler. Fabrication export is prohibited while any hard release hold remains open.
Change Notes
Initial specification captured from user requirements.
User authorized normal schematic development with a clearly marked provisional isolated whisker circuit.
User selected TE Connectivity DTM13-12PC-12PD-R008 and fixed the J1/J2 cavity-to-net assignments. Connector production geometry remains under a hard release hold pending official combined drawing/CAD verification.
Field whisker measurements completed: +5.0 VDC A-to-B when open/not-hit and 0.0 VDC when hit/closed. The isolated input is now specified around a low-current VOM617A-8X001T optocoupler; final bench loading validation remains required.
Project Overview
Intended Use
What the Device Should Do
Main Features
System Architecture
Hardware Subsystems
Power Input and Regulation
Compute and Programming
Relay Outputs
Isolated Whisker Input
Battery ADC
Ultrasonic Interfaces
Canopy Light Output
Interfaces and Connections
J1 Main Lift/Power — C-Key Bank of DTM13-12PC-12PD-R008