Update Pad Specifications and Route Traces


Change VIN and V- pads to through holes. Also fix all of the Airwires
I’ll update the VIN and V− pads to through-hole footprints, then inspect and route the remaining airwires and verify the result.
I found J1 pin 1 is VIN and J2 pin 1 is V−/VNEG; I’m applying explicit through-hole pad rules to those two pads, then I’ll rerun routing.
The two power pads now have explicit through-hole settings. The router check flagged congestion, so I’m going to spread the crowded center components slightly before routing.
Done: J1 Pin 1 (VIN) and J2 Pin 1 (V−/VNEG) are now explicit through-hole pads, and auto-routing completed successfully with 94 routing nodes added.
Open items:
  • Airwire check now reports no open/error/warning airwires.
Suggested next steps:
  1. Run a full DRC/ERC pass.
  2. Review routed trace paths around U1 and the trimmers.
  3. Export manufacturing files when ready.
Run checks and export
Run full DRC/ERC
Review critical routing
Check manufacturability
Export fab files

Last modified 4mo ago

Board Bring-Up Plan — Compact AD620 IA Module
Before Power
  • Inspect solder joints on U1, RV1, RV2, J1, J2, and 0402 passives.
  • Confirm no shorts between VIN, GND, and V- with a multimeter.
  • Set RV1 near mid-scale before first power-up.
  • Set RV2 near mid-scale before first power-up.
Power-Up Checks
  1. Apply current-limited supplies to VIN/GND/V-.
  2. Verify VIN to GND is the intended positive rail.
  3. Verify V- to GND is the intended negative rail.
  4. Confirm U1 +VS sees VIN and U1 -VS sees V-.
  5. Confirm REF voltage changes when RV2 is adjusted.
Functional Checks
  • Short SIGNAL+ to SIGNAL- and confirm VOUT is approximately REF.
  • Apply a small known differential input and adjust RV1 to verify gain changes.
  • Confirm VOUT remains within the available output swing for the applied supplies.
Pass/Fail Criteria
  • No supply rail short or excessive current draw.
  • REF adjustment is smooth and stable.
  • VOUT follows REF when differential input is zero.
  • VOUT changes polarity and magnitude correctly with SIGNAL+ vs SIGNAL- input polarity.
Notes
AD620 gain is approximately G = 1 + 49.4kΩ/RG. With the current 100Ω series limit and 100kΩ trimmer, expected gain range is roughly 1.5 to 495 depending on pot setting.
  • Before Power

  • Power-Up Checks

  • Functional Checks

  • Pass/Fail Criteria