Hardware Project Start
Waiting for input
Table
| Assigned item | Status | Evidence or blocker |
|---|---|---|
| Inspect live copper, persisted notes and preflight | Completed | 24 through-hole components, 62 pads, 17 nets; 160 × 100 mm board; preflight twice reported Board valid, no feasibility anomalies. |
| Clean redundant/incompatible copper | Completed inspection; no deletion needed | Initial and final redundant trace count zero; no Top/inner trace, fill or via existed initially. |
| Preserve topology, values, placement and board size | Completed | No schematic/placement/board mutation; final centers match initial scene read, all 24 rotations remain untouched. |
| Repair scope of Bottom annular rule | Completed rule edit; baked annular verification limited | Existing Home Etch Bottom Annular Copper ruleset selector changed from pad[padHoleType="STD"] to pad, retaining connectedLayers=Bottom !important and forceAnnularLayers=Connected only !important. All pads are TH. No sizes, drills or pad positions changed. The exposed scene read omits pad baked layer values; SVG colors pads according to component side, so that color alone does not prove annular-layer baking. |
| Targeted Bottom-only routing tool | Failed | Two GND attempts connected none of 12 pairs, including adjacent VR1 WIPER/CCW on an otherwise empty board. A real annular-rule adjustment and preflight recheck preceded retry. A later OUT4_FAN Bottom-trace-to-R10:P1 attempt also returned blocked-no-path. This is not evidence that all those connections are physically impossible: native Bottom geometry subsequently connected the same GND terminals. |
| Explicit GND, 12V, fan gate and switched return | Completed | Zero remaining airwires on GND, 12V, FAN_GATE and FAN_NEG. GND has 33 ordinary Bottom segments joining J1:2, C1:P2, C2:P2, U1:GND, R5:P2, R11:P2, Q1:S, LED1–LED4:K, VR1:WIPER and VR1:CCW. |
| Indicator anode nets, VR3_REF, VR4_REF | Completed | LED1_A through LED4_A, VR3_REF and VR4_REF have zero airwires. |
| OUT4_FAN, VR1_REF, VR2_REF, VSENSE | Completed partial copper; failed full completion | U1:OUTPUT4 to R9:P1 connected. R1/R2 and R2/R3 local ladder joints connected. TH1:2 to VR1:CW connected; U1 INPUT_1+, INPUT2+, INPUT3+ joined. Missing endpoints listed below. |
| OUT1, OUT2, OUT3 | Unattempted routing | No safe complete geometry was committed for these paths in the bounded pass. The new GND/power tree constrains their escape corridors; they need a deliberate copper-reroute strategy rather than guessed crossing traces. |
| Full-board autoroute, component moves, jumpers, exports | Unattempted, intentionally | None authorized/performed. Unrestricted bulk autorouting cannot enforce the required hard Bottom/no-via constraint through its exposed API. |
| Physical one-sided stackup conversion | Unattempted this pass; metadata limitation remains | Original four-layer metadata retained; previous attempt found Standard 1 Layer is Top-only. No routing or connection uses inner copper. |
| Final DRC, layers/widths/vias and routing-state readback | Completed | Evidence below. |
-81,-51 81,-51 81,51 -81,51. They persisted no routing. No repeated GND retry was made after its second failure.Table
| Net | Missing connection | Status / local obstacle |
|---|---|---|
| OUT1 | U1:OUTPUT_1 → R6:P1 | Unattempted. C2-to-U1 GND dogleg at x=-7 and y=15 constrains the left upper IC escape. |
| OUT2 | U1:OUTPUT2 → R7:P1 | Unattempted. Existing 12V trunk at x=-7 and GND/VSENSE routes require an alternative corridor. |
| OUT3 | U1:OUTPUT3 → R8:P1 | Unattempted. Direct upward path crosses the GND bus at y=4. |
| OUT4_FAN | U1:OUTPUT4/R9:P1 trace island → R10:P1 | Failed targeted attempt; trace endpoint used was Trace 9cad at (24,22) mm. Direct descent toward R10 crosses the GND fan-return branch. |
| VR1_REF | R1:P2/R2:P1 island → U1:INPUT_1- | Partial. Direct corridor crosses existing supply/ground copper near C2. |
| VR2_REF | R3:P1/R2:P2 island → U1:INPUT2- | Partial. Straight approach crosses the 12V trunk at x=-7. |
| VSENSE | U1:INPUT2+ island → VR1:CW/TH1:2 island | Partial. Sensor and IC islands are separated by existing power/ground routing. |
| VSENSE | U1:INPUT3+ island → U1:INPUT4+ | Partial. Straight same-row connection crosses U1:GND at (3.96875,4) mm; no crossing copper committed. |
Outcome
Live state recovered and work performed
Routing method and bounds
Exact remaining connections
Final verification
Handoff options — no approvals presumed