for Q5 what is the max voltage recomennded to come into the anode
6
please explain what Q5 does.
5
if 12v is present at the gate of q3 and 48v is at the drain of q3 will allo q3 t...
11
should i put r4 on the cathode ground side to avoid the voltage dropping too low...
7
do i need r4 at all? precharge to the anode is 3v3
8
for U1 there needs to be a cap connected to VOUT but the datasheet doesnt say th...
12
R7
Resistance
390 Ω
R16
Resistance
1kΩ
confirmed
confirmed
R7 is a power resistor
Q3
U1
Not Recommended for New Designs
Part Type
Sensor
Manufacturer Part Number
ACS70331EOLCTR-005U3