Safety Review and Architect Decisions
Status — 6 October 2026
HOLD: Do not energize Charger A. Keep J5 physically OPEN. Charger B and PCB layout have not started.
The captured project now contains 135 components and 83 net identifiers. The independent read-only review checked the first five blocks against saved requirements, actual net connectivity, ERC and focused component evidence. This file records the design-level findings and the decisions needed before protection redesign. It does not supersede the approved operating requirements.
Saved engineering deliverables
The firmware starter compiled but keeps charging disabled. Compilation does not validate active charger control. Simulations are bounded reconstructions of precharge, ADC and behavioral protection, not vendor-model proof of real switching behavior.
Captured blocks
Source fuse/reverse protection/precharge/reservoir, nominal 12 V and 5 V auxiliary supplies, Nano control, fan switch, protected logic-export interfaces, Charger A buck power path, isolated gate bias, current sensing/trip, latch/reset/timeout and ADC interfaces are captured. Physical component qualification and visual drafting remain incomplete.
C14–C16 remain the user's prototype-proven ZHUOYUAN 330 µF, 63 V baseline, explicitly parallel between CAP_A and PGND: 990 µF nominal. They are not rejected or substituted because listing data are incomplete. ESR, ripple/pulse endurance, current sharing and actual dimensions remain qualification tasks.
Confirmed control blockers
Ordinary current clipping incorrectly creates persistent lockout
Current connectivity establishes:
- CLEAR_A_BASE_N = OC_A_OK AND RESET_N.
- CLEAR_A_BASE_N directly clears U14.
- CYCLE_A_CLEAR_N = CLEAR_A_BASE_N AND ARMED_A.
- U14 CLK receives ARM_MANUAL_A; its D input requires PWM and CHG_A_EN low.
An ordinary current trip therefore clears both the cycle latch and the armed latch. Once current recovers, U14 remains disarmed and prevents the next PWM cycle from starting. This is first-trip manual lockout, not the required cycle-by-cycle limiting. Normal discharged-capacitor startup cannot be declared functional.
Correction direction: retain ordinary current-trip termination of the cycle latch and separate the persistent-fault latch. Implement a bounded persistent-short/stale-command qualifier before removing ordinary trip from U14. Simply bypassing U14 would remove required protection and is not approved.
Timeout does not prevent repeated stale-command restart
The enable-triggered window gates the command but does not clear the armed or cycle latches. A later enable edge after window expiry can reopen charging while PWM remains stale high, without a fresh PWM edge. A continuously high enable is bounded, but repeated enable events are not equivalent to persistent shutdown.
Correction direction: latch timeout of an active charge request as a persistent fault, clear the cycle state, and require PWM low plus deliberate safe reset before restart. Normal early completion must remain repeatable. Test enable chatter both during and after window expiry.
Architect decisions required
- Persistent-short qualification: What condition distinguishes valid startup/current clipping from a short? Define the maximum observation interval or retry budget, and whether qualification uses failure of CAP_A to rise, consecutive clipped cycles, or another independent measurement. Current clipping alone is expected during normal charging and cannot be an unconditional persistent fault.
- Timeout policy: Confirm that expiry while charging is still requested is a latched fault, whereas normal early completion does not latch a fault. Confirm that a stale-high PWM cannot restart through enable chatter after expiry.
- Reset policy: Confirm explicit/manual reset only while PWM and channel enable are low. Define whether any automatic retry is permitted and its bounded energy/time limit.
- Source envelope: Provide maximum source voltage/transient limits, available short-circuit current and reversed-reconnection policy. Without these, fuse/TVS coordination, diode reverse margin, and capacitor overvoltage protection cannot be released.
- Export interface: Specify receiver power-off tolerance and acceptable power-good delay. Recommend hardware suppression of PULSE_FIRE when exported power is faulty/not established rather than relying solely on firmware.
Decisions 1–3 change the hardware state machine and require approval before protection rewiring. Detailed thresholds must be checked against actual inductor energy, valid depleted-bank startup and worst-case source conditions.
Other release gaps
- Pulse-rated precharge resistor and retry duty are not qualified.
- Exact charger magnetics meeting the required RMS/saturation ratings remain unverified; generic properties are not qualified MPNs.
- Source fuse interruption, reverse reconnect with an already charged reservoir, TVS coordination and MOSFET-fault capacitor exposure remain open.
- Bank high-frequency/commutation bypass needs selection and verification.
- Export FAULT currently reaches the Nano but does not directly suppress PULSE_FIRE in hardware.
- Visual wire/label records near R24/R25 disagree with canonical net connectivity; reconcile before schematic handoff. This is not proof the canonical gate pull-down is electrically wrong.
- Exact Nano USB-power arbitration, rail-collapse ADC back-power behavior, isolated-bias startup, gate ringing, real trip latency/overshoot, thermal margins and capacitor endurance require hardware qualification.
ERC disposition
The latest inspected electrical checks contain two errors: U1 VIN is externally supplied but not recognized as driven; U3 Nano VIN is intentionally unconnected while +5 V powers the module. These are reviewed dispositions, not the above functional failures. Do not bypass source protection or connect Nano VIN just to silence ERC.
Next implementation and acceptance gates
After Architect approval, correct separated cycle/persistent-fault logic and timeout restart policy; address export health gating and visual-wire coherence. Verify a state matrix covering discharged startup, routine clipping, persistent short, stuck PWM, repeated enable edges, reset/brownout and idle-only reset. Then close component/source qualification and staged bench-test gates before enabling Charger A. Do not duplicate Charger A into Charger B until its corrected protection passes.