Getting Started with Flux
Qualify remaining capacitor MPNs against value, package and electrical requirements
Resolve or document actual IMU/USB ERC causes without suppressing checks
Repair evidenced routing blockers and verify fresh airwire/DRC counts
Waiting for input
Table
| Check category | Initial | Final |
|---|---|---|
| DRC Airwire Errors | 76 | 67 |
| Other DRC Errors in Error/Warning filter | 0 | 0 |
| DRC redundant-trace Warnings | 1 | 1 |
| Placement Warnings | 5 | 5 |
| ERC Errors | 10 | 10 |
Table
| Item | Status | Result |
|---|---|---|
| MOTOR2 output network | Completed | R8:P2–R12:P1, J3:2–D3:I/O2, R12:P1–D3:I/O2 saved; lengths8.839,15.072,49.351mm; five vias total; airwires76→73. MOTOR2_MCU remains unattempted. |
| MOTOR3 J3/ESD/pulldown island | Completed | J3:3–D3:I/O3 and J3:3–R13:P1 saved;12.581/23.307mm; three vias;73→71. |
| MOTOR3 R9:P2 to output island | Failed | One blocked attempt; final endpoint is trace39562657-4597-42a5-8963-4ac2f3431bab. |
| MOTOR4 J3/ESD/series-resistor island | Completed | J3:4–D3:I/O4 and R10:P2–J3:4 saved;13.052/16.814mm; two vias;71→69. |
| MOTOR4 R14:P1 pulldown branch | Failed | One blocked attempt; R10:P2–R14:P1 still unrouted. |
| VBAT_DIVIDED | Completed | R28:P2–R29:P1–R32:P1 saved;2.222/23.930mm, no new vias reported;69→67. |
| IMU_CLKIN | Failed | U1:PB15–U2:INT2/FSYNC/CLKIN blocked twice. Second attempt used only a nonpersisted Bottom steering keepout:4.1,-8.2 5.4,-8.2 5.4,-6.9 4.1,-6.9. |
| IMU_CS local pullup branch | Failed | R4:P1–U2:AP_CS blocked once; no blind repetition of historical rejected whole-net batch. U1:PA4 connections remain. |
| MOTOR1 output network | Failed | R7:P2/J3:1/R11:P1/D3:I/O1 batch atomically rejected: would introduce1 Airwire error. |
| ADC_CURRENT | Failed | U1:PC5/C22:P1/R33:P2/D7:I/O2: three blocked joins; zero saved. |
| ADC_VBAT | Failed | U1:PC1/C21:P1/R32:P2/D7:I/O1: two blocked joins and one rejection; batch would introduce1 Airwire error; zero saved. |
| CURRENT_DIVIDED | Failed | R30:P2/R31:P1/R33:P1 batch rejected: would introduce3 Airwire errors. |
| IMU_MISO, IMU_MOSI, FLASH_SCK | Unattempted | Fresh airwires confirmed. Prior file documents blocked escapes; no concrete upstream repair was established here, so identical retries were avoided. Historical blockers are not claimed as freshly measured. |
| IMU_INT, IMU_SCK; FLASH_CS/MISO/MOSI | Unattempted | No fresh airwires reported on these nets; existing copper preserved. No timing/SI qualification performed. |
| MOTOR1–4_MCU, raw sensing inputs and all other nets | Unattempted | Outside the selected ten-net batch. |
| Placement adjustment, full-board autoroute, USB repair, rule changes, EM, ESC mutations | Unattempted | No such edits/tests made. |
Scope and fresh measurements — 2026-10-11
Item results
Concrete blockers from this pass
Preserved constraints and unresolved gates
Next safe action