Chat


How can I help you?

Explain project
Write a project description
Find schematic issues

ERC/DRC Review — 2026-06-24
Project: SELV Spa-Light Switch Controller
Review timestamp from checks: 2026-06-24T15:06:41.299Z
Executive Summary
Schematic ERC and passive-component checks reported no open ERROR, WARNING, UNCERTAIN, or INFORMATIONAL findings for the selected categories. PCB/layout DRC is not clean: the board has substantial routing and copper integrity issues, including 102 airwire errors, 21 overlapping-copper/short errors, 2 floating-copper errors, 5 dangling-trace warnings, and 28 missing manufacturer part number errors.
Categorized Results

Table


CategoryCheckSeverityCountResult / ImpactRepresentative ItemsRecommended Action
Electrical Rule ChecksDriver conflicts, duplicate refs, floating pins, no-connects, pin-to-pin, shorted components, power pins, similar labels/powers, single-pin nets, undriven nets, dangling wires, unconnected wire endpoints, unannotated refs, multi-unit footprint/net/value mismatchPass0 openNo open schematic ERC findings returned for ERROR/WARNING/UNCERTAIN/INFORMATIONAL/OPEN statuses.None returnedNo ERC remediation required from current automated check output.
Passive ComponentsDecoupling capacitors, resistor power rating, pull-up/pull-down, capacitor voltage ratingPass0 openNo open passive-component findings returned.None returnedNo passive-rule remediation required from current automated check output.
Design Rule ChecksAirwiresCritical / Error102Board has many missing routed connections; PCB is not electrically complete and cannot be released for fabrication.Nets/pins reported include FB, P1, P2, JTMS, JTDO, JTDI, JTCK, RESET, EN, GND, VSS, SCL, OUT, VO, RC0, RB0 and others.Complete routing or rerun autorouting, then re-check airwires until zero remain. Prioritize power, ground, relay/coil, mains-sense, and programming/debug nets.
Design Rule ChecksOverlapping CopperCritical / Error21Copper elements are shorting or violating clearance; this can create electrical shorts and fabrication failure.Items reported around ea05f469, fc962d71, PWR, Trace fc96, PIN1, PIN2, S/D/G pads.Inspect reported copper objects and separate/delete/reshape copper. Re-run DRC after each repair pass.
Design Rule ChecksFloating CopperHigh / Error2Copper islands/traces are not connected to any net and may create EMI, assembly, or safety issues.Trace fc96 instances.Remove floating trace/copper islands or intentionally connect them to the correct net if they are required.
Design Rule ChecksDangling TracesMedium / Warning5Trace segments terminate without a valid connection; may be remnants from partial routing.Trace fc96 instances.Delete stubs or complete their intended connection.
ManufacturingMissing Manufacturer Part NumberHigh / Error28BOM is incomplete for procurement/manufacturing; affected parts cannot be uniquely sourced.R2–R14 selected generic resistors, C2–C14 selected generic capacitors, L1, J5 programming connector.Assign qualified MPN and manufacturer for every generic passive/connector, or mark parts as intentionally generic only if manufacturing flow supports it.
Missing MPN Components Returned by Check
  • Resistors: R2, R3, R4, R5, R6, R7, R8, R9, R10, R11, R12, R13, R14
  • Capacitors: C2, C3, C4, C5, C6, C7, C8, C9, C10, C11, C12, C13, C14
  • Inductor: L1
  • Connector: J5 programming connector
Key Interpretation
The schematic connectivity appears electrically consistent according to the currently returned ERC categories, but the PCB layout is not fabrication-ready. The dominant blocker is incomplete routing: 102 airwire errors indicate many schematic connections have not been implemented as copper. The overlapping-copper errors must be treated as critical because they may represent real shorts.
  1. Fix overlapping copper/short errors first, especially around PWR, MOSFET S/D/G pads, and objects tied to fc962d71/ea05f469.
  2. Remove or reconnect floating/dangling Trace fc96 copper.
  3. Complete routing for all 102 airwires; verify no remaining airwires.
  4. Assign MPN/manufacturer metadata for the 28 BOM-blocking components.
  5. Re-run full ERC/DRC and manufacturing checks before fabrication export.
  • Executive Summary

  • Categorized Results

  • Missing MPN Components Returned by Check

  • Key Interpretation

  • Recommended Remediation Order