This project was created on October 11, 2026, at 12:18 UTC, according to its metadata; its last recorded update was October 12 at 11:58 UTC. I haven’t started an autorouting job—the HTTP 500 came from the feasibility-check call I made in the previous turn, not from an old project error.
I’ll try starting the router directly, bypassing the failed standalone feasibility check—not the board’s clearance or routing rules. I’ll preserve the existing bottom-only configuration and placement, then check the result.
I bypassed the standalone check and attempted autorouting, but the router rejected its input: missing required field netClasses[0].viaPriority (BOARD_DEFINITION_GENERIC). No routes were added; 120 airwires remain, and fresh checks also report three capacitor escape errors at C1–C3; placement, outline, and stackup are unchanged. The missing provider field needs Contact Support—bypassing the HTTP check alone doesn’t resolve it.
The blocker is the router input missing netClasses[0].viaPriority, not your permissions or request wording; I can’t repair that provider field through the available design controls. Please Contact Support with this project and job ID auto-layout-e8f952dd-87c4-46a4-b934-5b20c80d200f so they can investigate the rejected input. Your board is unchanged—there’s no evidence that moving components or relaxing clearances would resolve this error.
Date: 2026-10-11. Document short ID: 9v. Assigned copper-clearance and nine silkscreen/mask-overlap repairs are complete and independently verified in the latest exports. This is not an unconditional manufacture-ready certification: C1/C4 placement warnings and broader exported KiCad rule/zone discrepancies remain documented below. The earlier text-only silk restriction was superseded by explicit authorization for project-local non-electrical graphic repair.
Scope outcomes
Table
Assigned item
Status
Evidence / remaining limitation
Fresh checks and actual defect identification
Completed
Native checks and independent exported geometry measured.
LED_OUT4_DRV/GND clearance repair
Completed
Three existing GND tracks changed; 0.105 → 0.130 mm.
Nine silk/mask-opening overlaps
Completed
9 → 0 regions; top overlap area 1.508774 → 0 mm²; bottom remains 0.
Orientation and polarity preservation
Completed
Three readable IC pin-1 rings recreated clear of mask; C4 polarity and all non-target silk unchanged to numerical tolerance.
Constraints preservation
Completed
52 unchanged top-side footprints; pads, mask, copper, placements, connections and board outline unchanged in this silk pass.
C1/C4 warning inspection
Completed
Two warnings remain; no safe localized routing-only remedy identified. Capacitor repair unattempted.
Updated Gerber/KiCad exports and independent verification
Completed
All Gerber geometry tests pass; zero native airwires and exported unconnected/short findings.
Overall manufacturing certification
Unattempted
Exported KiCad still reports pre-existing rule/zone and silk-to-silk discrepancies; no blanket readiness claim.
Order/payment
Unattempted, as required
No order or payment.
Exact latest downloads
These supersede the earlier partial-remediation exports:
The original GND horizontal bridge below U3 LED_OUT4_DRV ran from (22.705,-25.180) to (21.880,-25.180) mm. It now runs from (22.705,-25.205) to (21.880,-25.205) mm; its two adjacent diagonal join endpoints follow that 0.025 mm shift. Actual exported width remains 0.150 mm. The pad-to-bridge spacing improved 0.105 → 0.130 mm, meeting the unchanged 0.127 mm minimum with only 0.003 mm margin.
Original repair used two attempts: an atomic remove-and-reroute was blocked and applied no changes; surgical endpoint edits succeeded. A temporary width override was removed when export evidence showed it ineffective. Copper-stage mutations: 3 track geometries changed through 3 local UID rulesets, plus one ruleset cleanup update. This silk continuation made zero copper/via/pad/mask changes and retains the successful fix exactly. More copper margin would need a different escape topology or authorized placement change, not a relaxed limit.
Project-local silkscreen repair
The nine regions were not text: six capacitor duplicate fab-outline crossings and three IC pin-1 circles over pad-mask openings. A local UID ruleset suppresses 6 artwork nodes: C1/C2/C3 Fab Shapes and U1/U2/U3 Silk Shapes. Capacitor normal silk outlines and references remain. For the ICs, 6 standalone top-silk nodes were added: 3 body outline rectangles matching existing dimensions and 3 external pin-1 rings. Published library parts were not changed.
U1 outline: 8.8×3.04 mm at (0,-27); U2/U3 outlines: 6.66×3.54 mm at (−20,-27)/(20,-27). All recreated strokes are 0.15 mm. Final orientation rings:
Table
IC
Flux center mm
Diameter mm
Measured ring-to-mask clearance mm
U1
(−5.000,−29.770)
0.500
0.582139
U2
(−23.550,−29.870)
0.400
0.145998
U3
(16.450,−29.870)
0.400
0.145998
One cleanup pass shifted/reduced the U2/U3 rings after initial exported DRC found six new silk-to-silk interactions with C2/C3 graphics; those six findings are absent in the final DRC. No further attempts were needed. Silk-stage mutation counts: 1 suppress-artwork ruleset targeting 6 nodes, 6 added silk nodes, 2 marker-position/size rulesets. No text changes, component moves, component additions/removals, schematic edits, or manufacturing-limit changes.
Before/after overlap locations
Coordinates use Flux mm. Gerber conversion: gx=x+50, gy=y−50. Each listed region now has zero silk/mask overlap.
Table
Owner
Previous location
Previous area mm²
U1
(−3.810,−30.400)
0.277768
C2
(−25.500,−29.500)
0.159508
C2
(−25.500,−24.500)
0.159508
C1
(−3.810,−21.300)
0.159508
C1
(1.190,−21.300)
0.159508
C3
(14.500,−29.500)
0.159508
C3
(14.500,−24.500)
0.159508
U2
(−22.930,−30.512)
0.136980
U3
(17.070,−30.512)
0.136980
Fresh native and independent final checks
Final native review timestamp: 2026-10-11T16:29:47.567Z. Requested airwire, overlapping-copper, missing-footprint and invalid-layer checks returned no findings. A separate routing-state read reported 0 airwires, 0 redundant traces. Empty native output alone was not treated as exported-geometry proof.
Table
Check
Result
Final Gerber parsing
Passed: 9 layers, 1 drill file, 0 parse errors.
Copper ≥0.127 mm spacing
Passed: 0 subminimum isolated-region gaps on both copper layers.
Top smallest gap
0.130000 mm at Gerber (72.280,−75.065) = Flux (22.280,−25.065) mm.
Bottom smallest gap
0.142698 mm at Gerber (14.6339,−76.5537) = Flux (−35.3661,−26.5537) mm.
Silkscreen over mask openings
Passed: 0 top regions, 0 bottom regions, 0 mm² overlap.
Closed outline
Passed: nominal centerline 80×80 mm; plotted profile extent 80.05×80.05 mm includes stroke.
Component/pad preservation
Passed: all 52 footprints unchanged, all top; positions, rotations, pad dimensions, drills and pad-net assignments unchanged.
Electrical geometry preservation
Passed: exact Gerber geometry equality for top/bottom copper, mask, paste and edge profile versus the successful copper-stage export; exact PCB tracks/vias unchanged.
Silk outside target regions
Passed within 1e−10 mm² numerical area tolerance; residue 7.65e−14 mm². C4 polarity-region residue 2.86e−16 mm².
Exported KiCad connectivity/shorts
0 unconnected items, 0 short-type findings.
Overall KiCad DRC
Failed under exported rules: 879 findings, down from 957. No silk_over_copper findings remain.
Layer renders
Generated successfully and visually inspected; six-switch row and aligned IN/OUT LED rows preserved.
Assembly BOM/CPL/rotation validation
Not run in this scope; placement was independently confirmed unchanged.
KiCad final type counts: clearance 499, drill_out_of_range 79, silk_overlap 80, starved_thermal 22, track_width 199. The 78 silk_over_copper findings disappeared; no new silk-to-silk findings remain compared with the pre-repair export. Remaining silk_overlap includes pre-existing lettering/outline proximity, e.g. R20 and LED8 at board (33.023,58.6755)/(37.45,57.95) mm.
Exported KiCad uses rules different from native Flux: one example flags a 0.1490 mm LED_OUT2_DRV/GND gap against 0.2000 mm clearance, although the requested Flux minimum is 0.127 mm. KiCad also warns that legacy zone fills are converted best-effort; starved-thermal findings concern those zone representations, e.g. LED8 at (33.5,52.73) mm. These findings must not be counted as 879 established physical manufacturing defects, but were not exhaustively dismissed or reconciled. The actual copper and mask/silk categories assigned to this batch were checked directly in Gerber geometry. Gerber isolated-island spacing does not detect a short inside one connected island; native checks plus net-aware KiCad DRC support the zero-new-shorts conclusion.
Remaining C1/C4 warnings
Native Decoupling Loop Area still reports Warnings for C1 and C4. C1 bypass VCC pad (−3.81,−21.30) directly faces U1 VCC (−3.81,−24.23), already connected by a short straight 0.3 mm trace. C1 GND (1.19,−21.30) is approximately 8.87 mm from U1 GND (3.81,−29.77); this warning is principally pad/IC-pin geometry, not a missing route. A meaningful C1 improvement needs a separate placement/rotation decision rather than a speculative routing edit.
C4 is the supply-inlet bulk capacitor at (−35,30), not an IC-local high-frequency bypass. Do not move it away from the inlet just to satisfy an IC-loop heuristic. Both warnings remain documented; capacitor placement, values and schematic remain unchanged. Warning means possibly wrong, not confirmed error.
Render evidence and limitations
top
bottom
The scoped repair batch is complete; overall fab approval is separate. These checks do not replace fabricator DFM. Before ordering, inspect the latest Gerber in a viewer, confirm nominal 80×80 mm outline and drill sizes against selected parts, match BOM quantity to 52 components, and validate assembly rotations if ordering assembly. No manufacturing order or payment was performed.