Topology and Power Budget - HV Arbitrary Waveform Amplifier
Latest design baseline
- Signal input: +/-10 V arbitrary waveform
- Target output: +/-1000 V peak
- Load capacitance: 1.5 nF
- Frequency range: 0 to 500 kHz
- Overcurrent threshold: 6 A peak
- Burst operating assumption: full-scale 500 kHz operation is designed as a burst condition; initial sizing target is 10 ms maximum full-scale burst duration
- External interface limit: only three categories remain: voltage power supply interface, signal input interface, signal output interface
- Sourcing preference: domestic / China supply-chain preferred, but safety isolation, voltage rating, SOA, and thermal reliability have higher priority
Key calculations
10 ms full-scale burst update
Assumption: 500 kHz, +/-1000 V peak sine into 1.5 nF for 10 ms.
- Number of cycles in one burst: 5000 cycles
- Load peak current remains 4.712 A
- Load RMS current is about 3.33 A
- Reactive apparent power is about 2.36 kVA
- Energy stored in the load at peak voltage is 0.75 mJ
- Capacitive load energy is mostly exchanged back and forth; the 10 ms burst does not mean the load consumes 23.6 J as real power, but the output stage, bus capacitors, damping network, and energy recovery/dump paths must tolerate the instantaneous reactive flow.
Conservative early power-stage rule: size the local HV bus and dump/absorption network for at least one 10 ms full-scale reactive burst before relying on regenerative recovery. Using the apparent-power envelope gives about 23.6 J per burst for 1.5 nF. If the load is later changed to 2.5 nF, the same estimate becomes about 39.3 J per burst and the current rises to about 7.85 A peak, exceeding the 6 A limit.
Initial bus-capacitor sizing target: do not try to run the burst directly from the offline converter control loop. Use local HV bulk storage near the output stage. As a conservative placeholder, supporting roughly 25 J with a 650 V to 600 V rail droop requires about 800 uF total effective capacitance on the stressed HV storage rail. This is a sizing placeholder; final values depend on the selected BTL rail partition, recovery method, allowed droop, and real output-stage loss model.
Full-scale 500 kHz sine load current
Ipk=2πfCVpk
Ipk=2π⋅500000⋅1.5×10−9⋅1000=4.712 A
Conclusion: full-scale 500 kHz sine output needs about 4.71 A peak, below the 6 A overcurrent threshold. Peak-current margin is about 27%.
Maximum slew rate from 6 A current limit
dtdv=CI=1.5×10−96=4.0×109 V/s=4000 V/μs
Conclusion: arbitrary waveforms must be hardware/software slew-rate limited to 500 kHz
- 6 A peak analog hardware current limit; do not rely only on firmware
- Protection and interlock
- Overcurrent, overvoltage, undervoltage, overtemperature, short/arc detection
- Discharge rails and output to safe voltage after shutdown
- Enclosure interlock and HV-present indicator implemented internally, not as separate external interfaces
Schematic freeze blockers
Do not freeze power-stage schematic or PCB until these are resolved:
- Continuous full-scale 500 kHz vs burst / low-duty operation
- Floating differential output acceptable? If ground-referenced output is mandatory, topology changes
- Waveform fidelity: THD, phase error, flatness, overshoot, settling time
- Load tolerance: cable capacitance, open load, short, arc conditions
- Current-limit behavior: clamp, foldback, latch-off, or hiccup
- Cooling method: forced air, liquid cooling, heatsink size limits
- Power supply interface voltage range and maximum input power
- Safety standard target: IEC 61010, IEC 62368, medical, lab equipment, etc.
Next component-search priorities
- 1200 V / 1700 V SiC MOSFETs, prioritizing domestic or LCSC/JLCPCB-available parts
- Isolated SiC/MOSFET gate drivers with Miller clamp and sufficient CMTI
- HV feedback divider resistors and compensation capacitors
- Wideband current-sense devices or non-inductive shunts
- Certified AC/DC or isolated HV supply modules
- HV output connector, bleeder resistors, fuses, MOVs, and EMI filters