Both placement and routing need work: I found 112 unrouted connections, overlapping parts, and parts outside the board. I’ll keep the current 22 × 80 mm outline and four-layer stackup, correct placement, and check a suspect DDR connection to a memory power pin before routing it.
Thought for 16 mins 27 sec
20 days ago
Thought for 7 sec
2/3 Apply the required placement and auto-routing changes.
Inspect board placement, routing, and layout blockers.
Apply the required placement and auto-routing changes.
Verify the applied result and report remaining blockers.
Outside-board check: 1 error (L5), 13 warnings. Aggregate component extents 79.07 × 49.23 mm; do not infer actual outline orientation from summary alone.
Missing-power check: 8 errors: OSC1 VCC undriven on Net 1 1.8V; IC1 VDDIO, VBAT, VDD18, VDD33, VBUS unconnected; U3 VDD_7 and VDD_8 unconnected.
flux
20 days ago
I confirmed that both placement and routing need work: the initial checks found 112 unrouted connections, three overlapping component pairs, and outside-board violations.
The auto-layout task reported completion, but I couldn’t retrieve and verify its applied results before execution stopped; a suspect DDR address-to-power connection also needs confirmation. I saved the findings and recovery steps in Auto-layout inspection and resume notes.
2026-10-19. Both component placement and trace routing were needed. Placement edits were applied directly; this is a partial result, not a completed layout or manufacturing release.
Table
Assigned item
Status
Evidence / blocker
Inspect outline, stackup and placement
Completed
Read layout summary, tree, image, nets and fresh placement checks.
Preserve board and critical anchors
Completed
No board/stackup mutation; edge connector, U2, U3 and U4 were not moved or rotated.
Apply electrical-component placement cleanup
Completed with qualification
Last placement response reports 0 component overlaps, 0 keepout violations, and 1 remaining bounds finding: standalone MH1. Independent final checks remain unattempted because ACUs expired.
Mechanical compliance / MH1 correction
Unattempted
Preserved existing mechanical geometry; no authoritative mating datum was established for relocating MH1. No M.2 compliance claim.
Remove redundant copper
Completed
Deleted only the three check-reported redundant segments listed below; mutation reported redundant findings resolved. No independent final redundant check was possible.
Routing preflight
Failed
Two HTTP 500 failures during PCB bake; details below.
Neckdown generation and auto-routing
Unattempted / blocked
Confirmed dangerous DDR_A1 connectivity; no supported full-board net exclusion was established, and routing preflight also failed. Zero routing jobs; no run IDs.
Final read-only routing/placement checks
Unattempted after final mutation
ACUs expired immediately after the last placement edit. Earlier read-only checks and per-mutation findings are recorded below; do not treat them as final fresh checks.
High-speed EM, impedance and DDR timing validation
Unattempted
No EM/timing validation or length matching was performed.
Preserved constraints
Existing rectangular outline remains 22 x 80 mm, existing layout rotation 90 degrees, existing standard four-layer stackup approximately 1.30 mm thick. No resize or outline modification.
Placement API and PCB tree use layout-local coordinates, with the board spanning x = -11 to +11 mm and y = -40 to +40 mm. The summary reports rotated world coordinates; do not interchange them.
Edge Connector M.2 Key B retained local position (-9.3466, 37.8504) mm and its existing orientation. This does not establish a mechanically compliant M.2 card: the outline is still a plain rectangle and no mating geometry was validated.
U2 and both DDR devices U3/U4 retained their existing positions, orientations and top side. All ICs and RF connectors remain top side. RF baluns and connectors remain together at the negative-y end.
Five supporting passives are now bottom side: R5, R6, R7, R8 and L8. Other components remain top side.
No schematic connectivity, component values, footprint geometry, net widths, clearance rules, or historical DDR 0.08/0.06 mm rules were applied or changed. Functional Group properties were not added because schematic changes were outside this brief.
Applied placement
Twenty components were repositioned; five were also flipped. Final commanded/read-back positions below are layout-local millimeters. Existing rotations were retained except L7, rotated from 0 to 270 degrees local so its switch-connected P2 faces U13.
Table
Component
x
y
Side
U1
4.65
-16.0
Top
OSC1
9.0
-24.2
Top
U8
5.4
-24.2
Top
U16
0.0
-30.0
Top
L8
1.3
-27.4
Bottom
L7
8.2
34.2
Top
L5
8.5
10.8
Top
L1
8.4
-33.0874
Top
L2
2.8
-33.0771
Top
L3
-2.8
-33.0874
Top
L4
-8.4
-33.0873
Top
RF4
8.4
-37.3
Top
RF5
3.2
-37.3
Top
RF6
-2.0
-37.3
Top
RF7
-7.2
-37.3
Top
R5
5.0
32.5
Bottom
R6
5.0
29.0
Bottom
R7
8.0
29.0
Bottom
R8
6.3
34.1
Bottom
C2
6.6
31.0
Top
An initial L7 move used rotated summary coordinates incorrectly; it was immediately corrected to layout-local coordinates before continuing. L7's final state is the table above, not the intermediate out-of-board position.
Verification and before/after evidence
Initial layout read: 36 components, 952 pads, 87 nets, 35 route segments, 11 vias. Aggregate rotated-world component extents were 79.07 x 49.23 mm. Initial task handoff reported 112 airwires; this agent did not independently refresh that count before ACUs expired.
Fresh initial placement check at 18:56:29Z:
3 overlap warnings: U2/U1, RF4/RF5, RF6/RF7.
Bounds: 1 error (L5) and 13 warnings, including one standalone pad.
2 switching-stage errors at L7/U13.
1 board-density error; zero edge-placement and keepout findings.
Read-only check at 19:03:21Z, BEFORE the final corrective moves and redundant cleanup:
1 component overlap (L7/edge connector).
Bounds: zero errors and one standalone-pad warning.
6 overlapping-copper errors; 2 via-in-pad errors.
Switching Power Stage and Neckdown Escape: zero findings.
Later placement responses resolved the connector overlap and introduced via-in-pad conflicts. The LAST mutation response reports:
3 existing overlapping-copper issues resolved and 1 new overlapping-copper issue introduced.
1 via-in-pad issue resolved.
Estimated top utilization approximately 88% of usable area, still dense.
These are mutation feedback, not an independent final DRC. The latest total copper-error count, via-in-pad count, current airwire count, final aggregate extents, and final switching-stage status are NOT freshly verified. The board must not be described as DRC-clean or routed.
Copper preservation
Deleted exactly these redundant route segments, and no other copper:
32cfb132-aeec-467c-b266-c72ab6889a31
51ade9ed-6054-4053-8d98-3579877a9b65
fafd5f38-5d6b-4bf0-b155-9fb4889d2449
All other routes/vias were retained. Expected route-segment inventory is 32 after these deletions, but this was not independently re-read after the last mutation. No autorouter-generated routes were added.
Critical routing blocker: DDR_A1
Actual schematic net inspection, not merely a routing label, returned:
DDR_A1: U2:PS_DDR_A1_502, U3:VDDQ_1, U4:VDDQ_1
The U3 library pin map explicitly maps VDDQ_1 to package ball A1; its address pin named A1 is separately mapped to P7. This is consistent with accidentally using the package ball designation instead of the address-signal pin name. The Micron datasheet lookup verified that ball A1 of the x16 96-ball FBGA is VDDQ.
Therefore DDR_A1 must not be physically routed as currently connected. The U2 datasheet lookup was unsuccessful because its stored AMD URL did not return a PDF; the U2 package-level function was not independently datasheet-verified. This does not remove the concrete schematic fact that the named DDR address terminal is connected to both memory VDDQ_1 terminals.
The attempted datasheet query also suggested address A1 is P7, but that particular claim was not machine-verified; the P7 statement above is based on the inspected library pin map, not a verified datasheet extraction. Any repair must verify the authoritative pinout before changing connectivity.
Additional audit needed: full schematic wiring output includes nets named U2 PS_DDR_A2_502 - U3 DQ13, U2 PS_DDR_A3_502 - U3 DQ15, and U2 PS_DDR_A7_502 - U3 DQ12 associated with U2 address terminals. Do not confuse these with misleadingly named DDR_A2/A3/A7 nets that carry upper-byte DQ signals. Their actual merged connectivity needs a focused fresh net inspection before routing; no repair was attempted here.
Previously identified missing logical power connectivity also remains outside scope: OSC1 VCC on undriven Net 1 1.8V; IC1 VDDIO/VBAT/VDD18/VDD33/VBUS unconnected; U3 VDD_7/VDD_8 unconnected. Routing cannot repair absent schematic power connections.
Routing service failure
run_auto_route_check was called twice and failed identically:
No preflight result, neckdown output, routing run ID, or route application was produced. No additional retry should be made without resolving the service failure. An attempt to submit internal feedback failed; no ticket/report submission is confirmed.
Continuation checklist
Run fresh read-only placement and routing/DRC checks FIRST, including airwires, copper overlap, via-in-pad, redundant traces, switching stage and neckdown escape. Inspect the newly introduced copper issue from the last U1/L8 move; fix only that specific conflict within the retry budget.
Preserve the mechanical connector and current 22 x 80 rectangle/four-layer stackup. MH1 is a pre-existing standalone mechanical pad outside the outline: establish its intended datum before any move; do not guess M.2 compliance.
Investigate/repair DDR_A1 in a separately authorized schematic task with verified pinouts. Audit other suspect address/data wiring and missing power connections. Until then, only a routing method that provably excludes unsafe nets may run.
Resolve the PCB-bake feature-flag error before routing preflight. Determine current-based power widths and fabrication constraints before neckdowns; no power budget or fabrication target was established in this task.
When routing is safe, document the actual layer strategy and pass orthogonal preferences to every routing call. No new layer orientations or critical-net assignments were applied here. Preserve useful existing routes; delete only freshly verified redundant copper.
Generate safe fine-pitch escapes, route with at most three passes and stop on nonprogress, then freshly check placement, airwires and DRC. No high-speed, RF, USB impedance or DDR timing performance is validated by this placement result.
Execution stopped because the account ran out of ACUs immediately after the final placement mutation, before the planned final inspection.