Preliminary Safety Analysis
Status
Draft — architecture stage; not a certification determination.
Applicable Framework
  • EU Low Voltage Directive 2014/35/EU.
  • EN IEC 60335-1 and the correct product-specific Part 2 standard, subject to laboratory classification.
  • EN 55014-1/-2 and EN 61000-3-2/-3-3 for EMC intent.
  • RoHS material compliance.
  • UL/CSA-recognized components where practical.
Hazard Summary

Table


HazardSourceRequired Mitigation
Electric shock115/230 VAC wiring and heater switchProtective earth continuity, reinforced/basic insulation as applicable, barriers, creepage/clearance, touch-safe terminals, strain relief, enclosure controls
Fire/overheatingHeater stuck on, triac short, firmware hangIndependent 650–675°F thermostat in series, correctly rated fuse, nonflammable materials, watchdog, default-OFF gate network
Excessive temperatureThermocouple disconnect or driftDedicated sensor fault detection, plausibility checks, heater inhibit, visible fault state
Unsafe restartBrownout or power restorationHeater command held OFF through reset; deliberate state-machine re-entry
Insulation failureHeat, contamination, assembly damageTemperature-rated wire/insulation, physical segregation, conformal strategy only if compatible with thermocouple accuracy and service
EMC upsetTriac switching and mains transientsZero-cross burst control, surge/EMI filtering, watchdog, brownout supervisor, filtered thermocouple input, PCB partitioning
Safety-Critical Architecture
  • Protective earth is a hardwired path independent of the PCB control function.
  • The mechanical thermostat is hardwired in series with heater power and is independent of the MCU, thermocouple, and isolated supply.
  • The electronic heater switch is galvanically isolated from control electronics.
  • Fuse placement must protect downstream wiring and board faults.
  • Mains-side and SELV-side components must be visibly partitioned in schematic and layout.
First-Pass Schematic Safety Implementation
  • The protective-earth net runs directly from J1 to J2 and has no fuse, switch, relay, semiconductor, or firmware-controlled element.
  • The external mechanical thermostat loop J3 is in series with heater line power ahead of the electronic triac switch and remains functional with the low-voltage supply absent.
  • Heater command is active-high through an NPN driver; a 100 kΩ base pull-down keeps the optotriac LED off during reset and when the MCU is unpowered.
  • A zero-cross optotriac is used for burst/time-proportional control; phase-angle control is not implemented.
  • The mains input includes a replaceable fuse holder, MOV, common-mode choke, X2 capacitor, and discharge resistor. Final safety approvals, impulse ratings, spacing, and flameproof construction must be checked part-by-part during layout/BOM release.
  • The thermocouple input is filtered per the interface architecture and its FAULT output is wired to the MCU. Firmware must immediately de-energize the heater on open-circuit, over/undervoltage, implausible response, watchdog reset, or brownout recovery.
Required Evidence Later
  • Certified AC/DC module and optocoupler/optotriac approvals.
  • Actual creepage/clearance table based on material group, pollution degree, altitude, overvoltage category, and insulation class.
  • Earth-bond, dielectric withstand, leakage current, abnormal operation, locked-on heater, and thermal testing.
  • Final PCB/Gerbers, safety BOM, wire specifications, labels, user instructions, and accredited test reports.
Open Safety Questions
  • Product insulation class and whether protective earth is mandatory in every existing machine configuration.
  • Maximum installation altitude and contamination environment.
  • Exact safety thermostat type, tolerance, reset behavior, approvals, and mounting location.
  • Required branch-circuit fuse rating for both voltage variants.
  • Whether the appliance requires single-pole or double-pole disconnection under its final market/product classification.
  • Required creepage/clearance and any isolation slots for the intended altitude, pollution degree, material group, and overvoltage category.
  • Final heatsink arrangement and touch-safe guarding for Q1 and all exposed mains terminals.