Chat
Table
| Hazard | Source | Required Mitigation |
|---|---|---|
| Electric shock | 115/230 VAC wiring and heater switch | Protective earth continuity, reinforced/basic insulation as applicable, barriers, creepage/clearance, touch-safe terminals, strain relief, enclosure controls |
| Fire/overheating | Heater stuck on, triac short, firmware hang | Independent 650–675°F thermostat in series, correctly rated fuse, nonflammable materials, watchdog, default-OFF gate network |
| Excessive temperature | Thermocouple disconnect or drift | Dedicated sensor fault detection, plausibility checks, heater inhibit, visible fault state |
| Unsafe restart | Brownout or power restoration | Heater command held OFF through reset; deliberate state-machine re-entry |
| Insulation failure | Heat, contamination, assembly damage | Temperature-rated wire/insulation, physical segregation, conformal strategy only if compatible with thermocouple accuracy and service |
| EMC upset | Triac switching and mains transients | Zero-cross burst control, surge/EMI filtering, watchdog, brownout supervisor, filtered thermocouple input, PCB partitioning |
Status
Applicable Framework
Hazard Summary
Safety-Critical Architecture
First-Pass Schematic Safety Implementation
Required Evidence Later
Open Safety Questions