Edge13 Schematic Review


The PCB Placement Pass was already reconciled against the live board; no additional project changes were made this session.
Verified state:
  • All 134 footprints are placed: 81 top / 53 bottom
  • J3 USB-C: (27, −32.9) mm, bottom edge
  • J4 USB-A: (44.72, −21) mm, right edge
  • J5 USB-B: (−44.5, −21) mm, left edge
  • BT1: provisional bottom-side placement at (0, 2) mm
  • J1/J2 remain locked at (±17, 12.5) mm, 90° rotation, preserving the official 34 mm CM5 spacing
  • Board remains 110 × 75 mm, four copper layers
  • No reported component-body overlaps or out-of-bounds footprints
  • No routed traces exist; 285 airwires remain
  • The 18 pre-existing legacy GND via nodes remain
Remaining issues:
  • BT1’s 94.6 × 26 mm body conflicts with the fixed CM5/antenna region. Its position cannot be accepted until enclosure and vertical-clearance geometry are resolved.
  • D3 retains a library/differential-pair warning that must be reviewed before USB routing.
  • Routing congestion is expected near J1, U5, R17, R18, and TP11.
  • Connector plug/enclosure clearance has been planned geometrically but still requires enclosure-level validation.
Execution stopped because your ACUs ran out.
Received notification from "PCB Placement Pass" that it finished — picking the work back up.
The PCB Placement Pass was already fully reconciled against the live board. This is a duplicate completion notification, so no further changes were made.
Placement is complete; remaining unresolved items are the provisional BT1/CM5 mechanical conflict, the D3 USB warning, and enclosure-level connector clearance validation. No routing or schematic changes were performed.
stop all work
Stopped. No further project changes will be made.
Received notification from "PCB Placement Pass" that it finished — picking the work back up.
This is a duplicate completion notification. The placement pass was already reconciled, and the user subsequently ordered all work stopped. No further inspection, placement, routing, or project changes were performed.

PCB Pre-Placement Foundation Report
Scope status

Table


Scoped itemStatusEvidence / limitation
Board outline and four-layer stackupCompletedLive readback: 110.0 mm × 75.0 mm rectangle, four copper layers, reported total thickness 1.60 mm.
CM5 J1/J2 mechanical patternCompletedJ1 = (17.0, 12.5) mm, 90°; J2 = (-17.0, 12.5) mm, 90°. Center spacing = 34.0 mm. Both have !important position/rotation/layer anchor rules.
Four CM5 M2.5 holesCompletedFour 2.7 mm NPTH holes added at official datum-derived centers.
Wireless antenna keepoutCompleted15.0 mm × 8.0 mm all-layer HOLE/keepout zone reaches the +Y board edge.
CM5 top-side no-component regionCompletedSeven non-copper placement-exclusion zones cover the 55 mm × 40 mm CM5 body except the two connector footprint envelopes.
Four enclosure M3 holesCompletedFour 3.2 mm NPTH holes at practical 5 mm edge-center clearance.
USB differential-pair declarationsCompletedFour 90 Ω pair groups read back with correct partners.
Special/current net classesCompletedMax-current metadata and named minimum-width rules created.
Erroneous HOST_VBUS_500MA impedanceCompletedJ4 Part Type auto-mapping changed from USB-A to Connector; HOST_VBUS now reads only Power, 0.5 A, and a unique non-pair override—no controlled impedance. J4 MPN and connectivity were unchanged.
Obsolete 56-via GND gridCompleted with platform workaroundThe vias are virtual children of a legacy fill and cannot be directly deleted. The sole legacy fill is disabled with an active=false selector rule; live readback shows the remaining clipped virtual via nodes inactive. No replacement stitching was added.
Routing/general placement/schematic connectivityCompleted (not performed)Live layout has zero routeSegment nodes. Only J1/J2 were moved. No pin/net connectivity operation was performed.
Mechanical datum and exact geometry
Board coordinates use the board center as (0,0), +X right, +Y up. The CM5 is oriented with its antenna short end flush with the board top edge at Y=+37.5 mm. The 55 mm module axis runs downward; the 40 mm axis runs left/right.
Official source geometry
Sources used:
The official module-coordinate mounting centers (X,Y) are (3.5,3.5), (51.5,3.5), (3.5,36.5), (51.5,36.5) mm. Under the selected orientation they map to:

Table


HoleBoard X (mm)Board Y (mm)Drill / type
CM5_MH1+16.5+34.02.7 mm NPTH
CM5_MH2+16.5-14.02.7 mm NPTH
CM5_MH3-16.5+34.02.7 mm NPTH
CM5_MH4-16.5-14.02.7 mm NPTH
CM5 connectors

Table


ConnectorFunctionX (mm)Y (mm)RotationSide
J1CM5 pins 1–100+17.0+12.590°Top
J2CM5 pins 101–200-17.0+12.590°Top
Both footprints are Amphenol 10164227-1001A1RLF. The center-to-center vector J2→J1 is (+34.0, 0.0) mm. The official reference has both connector long axes parallel and both pin-1 ends toward the module antenna end; live pad readback confirms the selected 90° orientation places pin 1 toward +Y. Separate !important anchor rules are the strongest available locking mechanism because Flux exposes no dedicated component-lock property.
Antenna and CM5 body keepouts
  • Antenna keepout: center (-4.0,+33.5) mm, size 15.0 × 8.0 mm; bounds X=-11.5…+3.5 mm, Y=+29.5…+37.5 mm.
  • It maps to module coordinates X=0…8 mm, Y=16.5…31.5 mm, covering and exceeding the datasheet's 6.5 mm × 11 mm minimum antenna cutout and matching the recommended 8 mm × 15 mm size.
  • Rules: padHoleType=HOLE, connectedLayers=All, and keepout targets for elements, pads, vias, route segments, polygons, and zones.
  • CM5 body outline: center (0,+10.0) mm, 40.0 × 55.0 mm, bounds X=-20…+20 mm, Y=-17.5…+37.5 mm.
  • Because the selected 1.5 mm stacking connector provides no underside clearance, seven top-side element keepouts cover the body while excluding the mandatory connector envelopes.
Body exclusion rectangles:

Table


RegionCenter (mm)Size (mm)
Center(0,10)29.2 × 55
Left edge(-19.7,10)0.6 × 55
Right edge(19.7,10)0.6 × 55
J2 top(-17,30.775)4.6 × 13.45
J2 bottom(-17,-8.275)4.6 × 18.45
J1 top(17,30.775)4.6 × 13.45
J1 bottom(17,-8.275)4.6 × 18.45
Enclosure mounting holes

Table


HoleX (mm)Y (mm)Drill / type
ENC_MH1-50.0+32.53.2 mm NPTH
ENC_MH2+50.0+32.53.2 mm NPTH
ENC_MH3-50.0-32.53.2 mm NPTH
ENC_MH4+50.0-32.53.2 mm NPTH
Each center is 5.0 mm from its two nearest board edges. The bottom pair lies beyond the ±47.3 mm half-length of the 94.6 mm battery-holder envelope; the battery holder was not placed or moved.
Stackup
Live readback reports total thickness 1.60 mm:

Table


OrderLayerTypeMaterialThicknessDk / copper
1Top SilkscreenOverlay—0.000 mm—
2Top Solder MaskSolder MaskSolder mask0.020 mmDk 4.0
3Top CopperSignalCopper0.035 mm1 oz
4Prepreg 1DielectricFR-4 prepreg0.180 mmDk 4.2
5Mid-Layer 1Ground PlaneCopper0.035 mm1 oz
6CoreDielectricFR-4 core1.170 mmDk 4.3
7Mid-Layer 2Power PlaneCopper0.035 mm1 oz
8Prepreg 2DielectricFR-4 prepreg0.180 mmDk 4.2
9Bottom CopperSignalCopper0.035 mm1 oz
10Bottom Solder MaskSolder MaskSolder mask0.020 mmDk 4.0
11Bottom SilkscreenOverlay—0.000 mm—
Configured standard through via: 0.60 mm pad / 0.30 mm drill, L1–L4.
USB rules
All pair members are Net Type=High Speed, Controlled Impedance=90 Ω, tolerance 7.5%, and share explicit pair and bus-group names:

Table


Pair groupPositive netNegative net
HOST_USB2HOST_USB_DPHOST_USB_DM
SERVICE_USB2SERVICE_USB_DPSERVICE_USB_DN
ROSEPOINT_CONN_USB2ROSEPOINT_USB_DP_CONNROSEPOINT_USB_DM_CONN
ROSEPOINT_IC_USB2ROSEPOINT_USB_DPROSEPOINT_USB_DM
Physical rule: nominal/minimum width 0.15 mm, intended edge gap 0.15 mm, Top routing over continuous Mid-Layer 1 GND, matched within 0.5 mm, avoid layer changes. Flux's persistent PCB-rule schema supports width and pair metadata but does not expose a direct persistent differential-gap or length-tolerance rule; the gap/matching/via requirements are therefore recorded in the named ruleset description and must be supplied as routing constraints during the later routing run. Final impedance must be confirmed against the selected fabricator's actual pressed dielectric and copper values.
Current and special-net rules

Table


ClassNetsMax current metadataMinimum width
Battery/protection 10 APACK_POS, CELL_NEG_RAW, BQP_COMMON_DRAIN10 A3.0 mm
System/boost 10 ASYS_BATTERY_BUS, BOOST_SW10 A2.0 mm
USB-C/eFuse 3.3 AUSB_C_VBUS_RAW, EFUSE_5V_OUT3.3 A1.0 mm
CM5 5 V 3 A5V_CM53.0 A0.9 mm
Charger power 3 ACHARGER_SW, CHARGER_PMID3.0 A0.9 mm
Host VBUSHOST_VBUS_500MA0.5 A0.3 mm
GroundGNDGround type0.5 mm minimum if traced; use plane/pours
Routing-stage requirements not directly expressible as persistent width rules:
  • Use broad polygon pours rather than long traces for all 10 A paths.
  • For any 10 A layer transition, use at least six 0.30 mm finished-drill / 0.60 mm pad through vias in parallel as a starting requirement; validate current density and temperature rise after placement.
  • For 3–3.3 A layer transitions, use at least three such vias in parallel.
  • BOOST_SW and CHARGER_SW must be compact local switch-node copper, kept away from USB and sensitive feedback/sense nets.
  • GND intent is a continuous solid Mid-Layer 1 reference plane, with local top/bottom pours and later targeted stitching; no final stitching was added now.
Live verification notes and limitations
  • Board: 110 × 75 mm rectangle; four copper layers; 1.60 mm readback.
  • J1/J2: correct 34.0 mm relative spacing, same 90° rotation, fixed-rule anchors present.
  • Mechanical primitives: eight NPTH mounting holes, eight keepout zones, one 55 × 40 mm CM5 silkscreen outline, and one keepout label present.
  • Legacy grid: old fill reads active=false; virtual stitching vias also read active=false. Because virtual nodes cannot be deleted by UID, disabled virtual nodes may still appear in scene-tree counts but do not create active copper/drills.
  • Routing: zero route-segment nodes; 350 expected airwires remain.
  • General placement was intentionally not performed. Existing unrelated component coordinates were left untouched, so many components remain outside the resized board and some stale pre-placement coordinates intrude on the new CM5 area. They must be resolved by the later general placement run while respecting the new keepouts and J1/J2 anchors.
  • R14 readback remains 100 kΩ; R15 remains 8.2 kΩ; U9 remains MCP1700T-3002E/TT.
  • Schematic connectivity was not altered.
  • Scope status

  • Mechanical datum and exact geometry

  • Official source geometry

  • CM5 connectors

  • Antenna and CM5 body keepouts

  • Enclosure mounting holes

  • Stackup

  • USB rules

  • Current and special-net rules

  • Live verification notes and limitations