Relay Board Schematic Design


Here’s the schematic plan I’d use for the separate 10-channel 220 VAC relay board.
High-level architecture

Text


Control board harness
10x coil drive signals
        │
        ▼
Relay coil interface / flyback protection
        │
        ▼
10x 24 VDC relay coils

AC mains input
L / N / PE
        │
        ▼
Main protection ~50 A
        │
        ▼
AC live bus
        │
        ├── CH1 fuse 15 A ─ relay contact ─ output terminal CH1
        ├── CH2 fuse 15 A ─ relay contact ─ output terminal CH2
        ├── ...
        └── CH10 fuse 15 A ─ relay contact ─ output terminal CH10

Neutral and protective earth distributed to all output terminals
Schematic blocks to create 1. AC mains input
Use a high-current terminal block for:
  • AC_L_IN
  • AC_N_IN
  • PE_IN
For 220 VAC and high current, I would keep this as a physically separated high-voltage section with clear labeling and wide spacing.
2. Main input protection
Add one main protection device before the per-channel distribution.
Recommended options:
  • Panel-mount / chassis-mount breaker or fuse, not PCB-only, for ~50 A mains input.
  • If represented on the PCB schematic, use a connector or symbol for an external 50 A breaker/fuse.
  • Do not rely on a small PCB fuse holder for 50 A mains protection.
Suggested net flow:

Text


AC_L_IN → MAIN_FUSE_OR_BREAKER → AC_L_PROTECTED
AC_N_IN → AC_N_BUS
PE_IN   → PE_BUS
3. Ten relay output channels
Each channel should have:
  • HANKUK HR85AKS-DC24 relay
  • Replaceable 15 A fuse on the live output path
  • AC output terminal, preferably 3-pin:
    • switched live
    • neutral
    • protective earth
Recommended per-channel topology:

Text


AC_L_PROTECTED → CHx_FUSE_15A → relay COM
relay NO → CHx_L_OUT
AC_N_BUS → CHx_N_OUT
PE_BUS   → CHx_PE_OUT
I’d use the relay in normally-open mode unless you explicitly need fail-on behavior.
4. 24 V relay coil power input
Add a low-voltage power connector:

Text


+24V_COIL_IN
0V_COIL_IN
Then distribute:

Text


+24V_COIL → one side of all relay coils
coil low side → harness drive signal / transistor driver return path
Important question: are the 10 incoming control signals already low-side coil drivers, or are they just ESP32/logic-level signals?
  • If they are already ULN2803/open-drain low-side outputs from the control board, this relay board only needs coil connections and flyback handling.
  • If they are logic-level signals, this relay board needs transistor/MOSFET/ULN2803 drivers.
5. Harness connector from control board
Use a harness connector with at least:
  • COIL_DRV_1
  • COIL_DRV_2
  • …
  • COIL_DRV_10
  • 0V_COIL
  • optional +24V_COIL if coil power is also delivered through the harness
  • optional spare / key / detect pin
For reliability, I’d prefer the 24 V coil supply on a separate higher-current connector, not the signal harness, unless the harness is sized for relay coil current.
6. Coil flyback protection
Each 24 V relay coil needs suppression.
Options:
  • Diode across each coil: simple, low-cost, slower relay release.
  • TVS or diode + Zener: faster release, better for relay contact timing.
  • If the control board already has ULN2803A, note that ULN2803 includes clamp diodes, but the relay board still needs the correct COM clamp connection to +24V.
For a separate relay board, I’d put local flyback diodes or TVS protection on the relay board so protection stays close to the coils.
Safety/layout constraints to carry into the schematic
  • Keep low-voltage harness/24 V coil section physically isolated from 220 VAC contact/output section.
  • Use large creepage/clearance between:
    • AC live/neutral/PE and low-voltage control
    • relay contact pins and coil pins
    • adjacent high-current channels
  • Use wide copper or copper pours for 15 A paths.
  • Consider using slots/cutouts between relay coil/control pins and contact pins.
  • Label all high-voltage nets clearly.
  • Prefer external/chassis wiring for the full 50 A main feed if PCB copper thickness/width cannot safely support it.
Open design decisions before schematic capture
  • Are the incoming 10 control signals logic-level inputs or already coil-driver low-side outputs?
  • Should each output socket switch live only, or live and neutral?
  • Should the board include current sensing or status feedback per channel?
  • What connector style/current rating do you want for the AC input and outputs?
  • Will the 50 A main protection be on-board, panel-mounted, or external?
My recommended starting schematic is: external/main 50 A breaker → live bus → 10× 15 A fused normally-open relay channels, with neutral and PE distributed directly to each output, and local flyback suppression for all 24 V relay coils.
Use low-side drivers
Add relay drivers
Switch live only
Specify connectors
Create schematic plan

Waiting for input


HANKUK HR85AKS Relay Selection
Date: 2026-06-15
Decision
The HANKUK HR85AKS-DC24 relays are off-board parts. The low-voltage PCB contains only J2–J11 relay coil connectors and the driver electronics that energize the external 24 V relay coils.
Relay contacts and 240 VAC load wiring are not on this low-voltage PCB section.
Selected Off-Board Relay
Confirmed Electrical Ratings

Table


ParameterValue
Coil voltage24 VDC
Coil resistance640 Ω ±10%
Rated coil current37.5 mA
Rated coil power0.9 W
Operate voltage18.0 V
Release voltage2.4 V
Max coil voltage31.2 V
Contact rating40 A at 240 VAC resistive / 40 A at 30 VDC resistive
Max switching capacity9600 VA AC / 1200 W DC
Max switching voltage240 VAC / 110 VDC
Correction to Earlier Assumption
The previous driver sizing used 30 mA per relay coil. The HR85AKS-DC24 datasheet lists 37.5 mA nominal at 24 VDC.
Updated all-on relay coil current:
10 × 37.5 mA = 375 mA
Updated coil load power:
10 × 0.9 W = 9.0 W
The 24V_RELAY net is set to 0.375 A nominal with 0.5 A max/current-budget target.
PCB Assignment: J2–J11 Are Coil Connectors Only
J2–J11 were restored as DORABO DB127V-5.08-2P-GN-S terminal block connectors in the BOM.
Each connector is documented as:
  • Connector function: off-board relay coil connector only
  • Connector MPN: DB127V-5.08-2P-GN-S
  • Connector manufacturer: DORABO
  • External relay reference: HANKUK HR85AKS-DC24 / HR85AKS DC024
  • Per-channel coil load through connector: 24 VDC, 37.5 mA nominal
  • Relay contacts: off-board / external high-voltage section only
BOM Handling
The manufacturing BOM for this low-voltage PCB should include:
  • 10× J2–J11 terminal blocks: DB127V-5.08-2P-GN-S
The external assembly / wiring BOM should separately include:
  • 10× off-board relays: HANKUK HR85AKS-DC24
Do not place HR85AKS relay footprints on this low-voltage PCB unless the project later adds a separated mains/high-current relay board section.
Driver Sizing Impact at 37.5 mA Coils
  • ULN2803A path remains within per-channel current capability.
  • 2N2222 manual path remains within current capability.
  • 1 kΩ base resistor from 5 V gives about 4.3 mA base current, forced beta ≈ 8.7 at 37.5 mA, still acceptable for saturation.
  • 1N4148 diode-OR dissipation increases to roughly 30–38 mW per energized channel, still likely acceptable but should be checked against the exact diode package/ambient.
Layout Notes
  • Route J2–J11 as low-voltage 24 V coil wiring only.
  • Keep AC contact wiring off this board unless a separate mains-safe PCB area is explicitly designed.
  • Label J2–J11 clearly by channel and polarity/function during layout.
  • Decision

  • Selected Off-Board Relay

  • Confirmed Electrical Ratings

  • Correction to Earlier Assumption

  • PCB Assignment: J2–J11 Are Coil Connectors Only

  • BOM Handling

  • Driver Sizing Impact at 37.5 mA Coils

  • Layout Notes