Project Specification — 10-Channel 24V Relay AC Distribution Board
Summary
This board is a 10-channel relay output board that pairs with a separate control board. The control board already provides low-side coil drive outputs using ULN2803A arrays plus per-channel 2N2222 manual override paths combined by diode-OR, so this board contains no additional coil drivers.
Electrical Architecture
- Relay: HANKUK HR85AKS-DC24 target relay, 24 VDC coil, 640 ohm, 37.5 mA, 0.9 W, 40 A / 240 VAC contact rating.
- Library limitation: exact HR85AKS-DC24 was not available in Flux; the schematic uses G4A-1A-E DC24 as a temporary SPST-NO schematic carrier. The relay BOM fields are overridden to HR85AKS-DC24 and the footprint must be custom-verified before layout.
- Coil supply: +24V_COIL shared across all 10 relay coils; total current about 375 mA.
- Coil drive inputs: CH1_COIL_DRV through CH10_COIL_DRV are already low-side coil-driver outputs from the separate control board.
- Flyback: one local 1N4007 diode per relay coil; cathode to +24V_COIL, anode to the channel low-side drive return.
AC Power Topology
- Main 50 A protection is external and chassis-mounted; the PCB receives the already protected live feed on AC_L_PROTECTED.
- Live only is switched.
- Per channel: AC_L_PROTECTED -> CHx 15 A replaceable fuse holder -> relay COM -> relay NO -> CHx live output terminal.
- Neutral and PE are distributed directly to every output terminal block; they are not switched.
- Output terminal blocks are 3-position per channel: live output, neutral, PE.
Connector Plan
- J1: protected AC live input terminal block.
- J14: AC neutral input terminal block.
- J15: protective earth input terminal block.
- J2-J11: per-channel AC output terminal blocks.
- J12/J13: two 6-position low-voltage harness terminal blocks for +24V_COIL, CH1-CH10 coil drive returns, and one spare terminal.
Safety and Layout Requirements
- Treat AC_L_PROTECTED, AC_N, PE, CHx_FUSED_L, and CHx_L_OUT as mains/high-current nets.
- Use wide copper or copper pours for high-current AC paths; final trace width must be calculated from copper weight, board thickness, permissible temperature rise, and per-channel current.
- Maximize creepage/clearance between AC section and low-voltage coil/harness section.
- Keep 24 V coil harness and flyback diode wiring physically isolated from relay contact/fuse/output live copper.
- Verify fuse holder AC voltage rating, agency approvals, accessibility, and fuse type before manufacturing.
- Verify terminal block ratings, conductor gauge, enclosure strain relief, and code compliance before connecting mains.
Open Items Before Layout
- Create or import the exact HANKUK HR85AKS-DC24 symbol/footprint from datasheet dimensions.
- Confirm relay contact pin mapping for HR85AKS-DC24 against its datasheet before routing.
- Confirm per-channel fuse value and fuse holder safety rating for the target load type.
- Define board dimensions, copper weight, creepage/clearance rules, and conductor current targets.