Critical Power Path / Backup Hold-Up Item — LM66100, AXP2101, AP63203
Current locked intent from user
- U2 MP2315: 12V input buck to the main +5V rail.
- U8 AP63203: buck converter that generates +3V3 and is the only source of +3V3.
- U7 AXP2101: charger/PMIC connected to the +5V rail for LiPo charging and backup-power management.
- U3A/U3B LM66100: POPULATED ideal-OR / source-selection devices. Do not mark these DNP and do not remove them.
- Power-loss requirement: when 12V disappears, the LiPo path via AXP2101/LM66100 must keep the system rail alive briefly so +3V3 remains up for graceful shutdown and cloud notification.
Important correction
The previous note identified that LM66100 cannot be used directly on a 12V node. That remains true, but the resolution is not to DNP the LM66100 devices. They must remain populated and used only within their allowed voltage domain.
Open EE decision
The exact backup topology is intentionally left open for human EE review:
-
AXP SYS feeds AP63203 VIN
- AP63203 input is battery-backed through the AXP SYS output.
- EE must confirm AXP SYS voltage range and AP63203 minimum input/headroom across LiPo discharge.
-
Battery/AXP output ORs into the 5V/system rail using LM66100
- AP63203 VIN sees a backed-up rail instead of raw MP2315 5V only.
- EE must confirm the ORing voltage domain, current capability, voltage drop, and whether the backed-up node remains inside LM66100/AP63203 limits.
Schematic-capture instruction
Capture the intent that the AP63203 input is battery-backed, not powered only by the MP2315 5V node that dies with 12V. Keep U3A/U3B populated. Label the unresolved node/topology as an OPEN EE REVIEW ITEM rather than deleting or DNP-ing parts.
Constraints to preserve
- +3V3 is generated only by U8 AP63203.
- U7 AXP2101 does not directly generate the final +3V3 logic rail.
- U3A/U3B remain populated ideal-OR elements.
- No LM66100 pin may be connected to a 12V net.
- Human EE must finalize analog/power placement and backup topology before release.