Power Tree ERC Residuals
Verified fixes
+3V3_RADIO is physically driven by TPS56837 U5 through L2 and is declared a Power net rated 6 A continuous / 8 A maximum.
+3V3_AUX is physically driven by TPS7A2033 U7 OUT and is declared a Power net rated 0.3 A.
- The prior 13 Missing Power errors on U8/U9/U10, U3, and U11/U12/U13 are cleared without adding dummy power sources.
- Generic resistors, capacitors, and inductors now have SMD package assignments. High-current shunts use 2512; bulk and power-stage capacitors and inductors use appropriately larger packages.
Justified future-interface residuals
The only remaining electrical review findings are five single-pin STUSB4500 nets intentionally reserved for the future supervisor/control block:
PD_VBUS_EN_N — U1 VBUS path-enable status/control output
PD_PDO2_OK_N — U1 PDO2 contract status
PD_PDO3_OK_N — U1 PDO3 contract status
PD_FAULT_N — U1 GPIO configured as hardware fault indication
PD_CABLE_SIDE — U1 cable-orientation indication
No dummy components were added. These nets should be connected when the supervisor is introduced. Flux currently reports a single-pin-net error for intentional named interface stubs.
Radio branch status limitation
MP5077 U8/U9/U10 has no digital fault output pin. The design therefore retains RADIO1_EN/RADIO2_EN/RADIO3_EN, hardware current limiting and thermal/short-circuit protection, and analog telemetry nets RADIO1_CURRENT, RADIO2_CURRENT, and RADIO3_CURRENT. No fictitious fault signal was created.
Schematic arrangement blocker
The schematic placement is not acceptably legible: support passives remain in auto-generated banks away from their IC blocks. The current Agent toolset exposes schematic inspection and connectivity/property mutation, but no schematic component-arrangement mutation tool. This prevents completing the requested left-to-right arrangement in this session without deleting/recreating valid wired components.