Sensirion Handling and Packaging
Mandatory factory rules
- ESD controls are mandatory throughout receiving, kitting, placement, rework, test and packaging.
- Do not apply board wash or expose the sensor to cleaning agents, alcohols, ketones, solvents, strong air blasts, oils, fingerprints, uncured polymers, flux residues, or concentrated VOCs.
- Use no-clean type ≥3 solder paste and assemble SHT45 in the last reflow cycle.
- No ultrasonic cleaning is permitted by project policy. The current SHT handling document does not explicitly use the word ultrasonic, so this is a conservative product requirement rather than a quoted Sensirion statement.
- Do not touch, press, wipe aggressively, clamp, gasket-load, or use the membrane/package as an axial stop.
Coating and potting control
- Dimensioned PCB no-coat zone: entire sensor end from the exposed tip through the end of the narrowed neck, approximately the first 9 mm of the 35 mm blade in the current layout; enlarge to include all of U1/C1 and the isolation transition on the released drawing.
- No coating on top, sides, membrane, underside keepout, or airflow cavity around U1.
- Coating/potting is allowed only at the connector/rear section after material compatibility and cure/outgassing validation.
- Use a physical mask and inspection witness; do not rely on operator aiming.
- Do not use adhesive-lined heat shrink, hot melt, silicone, epoxy or label adhesive near the sensor/neck unless fully cured and qualified.
Reflow and rework
- Use a qualified Pb-free convection profile per J-STD-020; current Sensirion handling guidance allows peak 260 °C for up to 30 s.
- Manual sensor soldering is not the production method. If exceptional rework is authorized, limit local solder contact to 5 s at up to 350 °C and protect the membrane from hot-air blast.
- Expect a temporary negative RH offset after reflow. Do not set tight final RH limits immediately after soldering without rehydration/conditioning.
Storage and packaging
- Keep sensors in original sealed packaging until use and process within the manufacturer-recommended shelf period.
- Use metal-in shielded ESD bags, clean paper/cardboard, or qualified PE/PET/PP trays.
- Do not use ordinary antistatic polyethylene bags, bubble wrap, foam, or large adhesive labels inside the sealed package.
- Package only after all adhesives, inks, coatings and potting are fully cured and the assembly has been ventilated.
- Include a clean, non-shedding tip guard that does not contact the membrane and is removed before use.
Conditioning and reconditioning
- Normal post-reflow recovery can occur over several days at approximately 50–70 %RH.
- If a formal reconditioning process is needed, current handling guidance suggests baking at 100–105 °C and <5 %RH for 10 h, then rehydrating at 20–30 °C and about 75 %RH for 12 h.
- Apply that process only to an assembly whose PCB, connector, wires and materials are rated for it; otherwise recondition bare sensor/PCBAs before enclosure assembly or use the slower ambient recovery route.
- Reconditioning is recovery, not a substitute for contamination prevention.