Fabrication Readiness
DFR0379 LM2596 buck module, but the project does not identify the 7-inch display or its maximum current. Therefore, available current margin cannot yet be confirmed safely.SSW-108-02-G-S 2.54 mm female socket, not a locking cable connector. It is approximately 21.35 × 3.55 mm and located inside the board rather than at an edge. The vertical mating direction is clear, but exact cable/plug clearance cannot be validated without the mating connector housing and cable exit direction.Waiting for input
Table
| Phase | Estimated completion | Current state |
|---|---|---|
| Schematic architecture and component selection | 90% | Major functional blocks are present. Reset and high-side power-switch circuits exist, but final connectivity review is still required. |
| PCB placement and mechanical fit | 90% | All 79 layout elements are placed on a 160 × 185 mm four-layer board. USB1 extends beyond the nominal component bounding limit and should be confirmed as intentional edge placement. |
| PCB routing | 97% | 0 airwires remain. Five dangling-trace groups remain and must be removed or intentionally reconnected. |
| ERC/DRC cleanup | 85% | One ERC error remains (SW2:4 floating) and five dangling-trace warnings remain. No other current open errors/warnings were returned by the full review query. |
| BOM and sourcing | 85% | BOM contains 74 instances across 29 unique part groups. Many parts have MPNs, but generic resistor/capacitor grouping and ratings should be audited before ordering. |
| Manufacturing release | 60% | Final DRC/ERC signoff, mechanical review, fabrication exports, assembly data, and final visual inspection are not complete. |
RESET_EN currently includes two SW2 terminals.SW2:4 is reported floating by ERC.RESET_EN and the opposite full pair to GND.022d, 5441, e215, ee06, and fc18.12V_SW.12V_SW and no board load bypasses the switch.SW2:4 floating)Overall Estimate
Completion by Phase
Remaining Critical Work
Recommended Finish Order
Current Live Metrics