Project Start
Complete the existing hub schematic and resolve interface and power evidence
Independently review the completed schematic and fix blocking findings
Complete the existing hub schematic and resolve interface and power evidence
Independently review the completed schematic and fix blocking findings
Waiting for input
Table
| Load | Rail | Maximum / allocation | Status |
|---|---|---|---|
| CY7C65642 hub | 3.3 V / internal domains | 105.4 mA published maximum for the retained operating condition | Datasheet evidence retained |
| 4× TUSB320LA + logic | 3.3 V | Not yet bounded from worst-case datasheet values | Open |
| Internal AC1200 card | 5 V | 2.7 W / 5 V = 540 mA | Vendor maximum; transients unknown |
| Three external ports | 5 V | 500 mA each provisional USB2 allocation | Not approved simultaneously |
| Switch and copper losses | 5 V | Depends on load and layout | Open |
Status
Load Inventory
Demand Cases
Provisional Hardware Limits
Qualification Procedure
Release Rule