Schematic Layout and Wiring


I’ll arrange the schematic into readable functional blocks, draw local wires and net labels, and verify that every electrical connection stays unchanged.
Thought for 11 mins 25 sec
Thought for 7 sec
Created 2 tasks.
1/2 Arrange and wire every functional block without changing connectivity.

Arrange and wire every functional block without changing connectivity.

Verify schematic readability and unchanged electrical connections.

Thought for 17 sec
Awaiting 1 task
"Schematic Layout and Wiring" completed.
Created a project doc

Schematic drafting handoff

View Document

Schematic drafting handoff Request
Arrange all existing components into readable functional blocks, draw local wires and net labels, and preserve all electrical connections. Do not alter component values, components, net names or net membership.
Session state
The full schematic drafting task was dispatched. The dispatch returned executor reference 8a (persisted ID), initially active. A subsequent completion notification states that "Schematic Layout and Wiring" completed. Its detailed result has not been retrieved or reviewed, so actual mutations, connectivity preservation, and drawing quality are not yet verified. Do not assume the schematic is untouched or finished.
Execution stopped because the account ran out of ACUs before result reconciliation.
Resume
The schematic arrangement and wiring pass reported completion, but I haven’t yet inspected the result or verified that all electrical connections stayed unchanged. I saved the remaining verification steps in Schematic drafting handoff.
Execution stopped because your ACUs ran out.

Waiting for input


Project Specification
Project Overview
Status: Draft — architecture validation, not approved for fabrication or energization.
A carrier for the TI LAUNCHXL-F28P55X LaunchPad controlling a 25 kW three-phase hybrid inverter. The requested measurement limits are 400 V RMS AC line-to-neutral and 1200 V DC. The user clarified an approximately 300 V battery/capacitor DC bus and confirmed 300 V as the maximum battery charging voltage; 1200 V is the requested sensing-range maximum, not the stated operating voltage. Abnormal bus overshoot and transient limits remain unspecified. The user authorized revisions to unsafe protection and sensing requirements.
The uploaded design proposal is retained as the detailed requirements baseline, including its complete socket map, component values, floorplan, connector pin assignments, and deliverables. Its statements that dimensions and pinouts are verified are not accepted as evidence. The changes and unresolved constraints below take precedence. All baseline requirements remain tracked rather than silently discarded.
Intended Use
  • Controller carrier, not the inverter power stage; intended use involves hazardous mains and DC-link potentials.
  • Development use of accessible LaunchPad USB/debug creates an important isolation boundary.
  • Confirmed installation: indoors, approximately 770 ft (235 m) above sea level. Contamination, condensation and operating temperature remain unspecified.
  • Market, applicable product standard and prototype/production qualification are not yet supplied.
  • Do not connect this unvalidated design to hazardous voltages.
What the Device Should Do
  • Measure three AC voltages, one DC-link voltage, four external Hall-sensor currents and four NTC temperatures.
  • Provide galvanically isolated voltage measurement, not insulation-resistance monitoring or earth-leakage detection. This clarification is consistent with the isolated voltage channels in the original proposal.
  • Supply the LaunchPad and carrier electronics from external +15 V / 0 V / -15 V.
  • Provide six inverter PWM signals, two MPPT PWMs, driver enable and driver fault feedback.
  • Communicate over isolated CAN and isolated RS-485, plus nonisolated RS-232.
  • Connect an external display and eight buttons, with status indicators and test access.
  • Default to a defined gate-driver-safe state during reset, loss of power and faults; precise safety behavior remains to be specified.
Main Features
Four isolated voltage channels; four +/-100 A nominal external current sensors; four 10 kohm NTC channels; external 3.000 V ADC reference; LaunchPad sockets; communication termination options; display backlight switch; service test points.
Mechanical System Architecture
Bare carrier PCB with a plug-in LaunchPad, off-board sensors, display and buttons. An enclosure is not requested, but enclosure and mounting insulation affect safety qualification.

Diagram


Carrier PCB Plug-in LaunchPad Four voltage connections External sensors and user interface Mounting and enclosure interfaces
  • Target board: 280 x 240 mm, 4 mm corner radius, four layers, 1.6 mm nominal FR-4, 1 oz copper; ENIG, green mask, white silkscreen.
  • Mounting, connectors and LaunchPad keepout follow the uploaded coordinates as targets, pending authoritative geometry and safety validation.
  • The high-voltage floorplan and slots may change if required by spacing, connector ratings or protection hardware.
Electrical System Architecture
Retain isolated analog sensing as the provisional primary topology. AMC3330 suitability is conditional on system isolation requirements; no complete-board safety claim follows from a component rating.

Diagram


400 Vrms AC and 1200 VDC Rated sensing and protection boundary Four isolated analog voltage channels Conditioning and ADC filters External Hall sensors Four NTC inputs LaunchPad controller Default-off PWM interface CAN RS-485 RS-232 Display and buttons
Hardware Subsystems

Table


SubsystemBaseline and disposition
MCU interfaceLAUNCHXL-F28P55X four dual-row sockets, no carrier connection to LaunchPad 3.3 V outputs; complete map in source; verify physical and electrical mapping before capture.
Power+/-15 V input protection, 5 V buck, digital and analog 3.3 V rails; validate currents, startup, TVS coordination and thermal paths.
Reference3 V reference and 1.5 V bias; verify ADC reference connection, load and stability.
TemperatureFour ratiometric NTC dividers with RC filtering and ESD.
VoltageThree 400 Vrms channels plus one 1200 VDC channel with galvanic isolation. Revise the DC divider. User locates MOVs and fuses at the inverter terminals, outside this carrier; actual ratings and residual transient limits remain unverified.
CurrentFour externally powered LEM sensor interfaces, burdens and biased amplifiers; verify actual sensor variant and current envelope.
PWM5 V buffers, output pull-downs and fault input; verify MCU tolerance and hardware shutdown requirements.
CommunicationsIsolated CAN and RS-485 with separately managed isolated domains; nonisolated RS-232. Exact transceiver variants and pinouts remain unverified.
UIEight buttons, SPI/I2C display header and backlight switch.
Interfaces and Connections
The uploaded specification contains all requested connector and socket net assignments. These are proposals requiring manufacturer verification, not permission to connect incompatible pins. External VREF cable, gate-driver interface and USB/debug grounding need explicit integration review. Do not place HV connectors using only nominal pitch: select actual voltage-rated terminals and holders first.
Power and Runtime Expectations
External continuous +/-15 V operation; no battery or runtime target for the carrier. Input tolerance, available current, LaunchPad draw, display consumption and worst-case sensor/transceiver loads remain unspecified. No regulator thermal or current-capacity approval yet.
Power Tree and Power Budget

Diagram


External plus 15 V Positive rail protection External minus 15 V Negative rail protection Hall sensor supplies 5 V buck LaunchPad and 5 V loads Digital 3.3 V regulator Filtered analog 3.3 V regulator Reference and bias
Per-rail currents are not yet verified. Prepare a sourced load budget before selecting final regulators, protection and copper dimensions. The original LDO tab-to-GND pour instruction conflicts with its own OUT-tab assignment; never implement that short circuit.
Manufacturing and Assembly Expectations
LCSC preferred sourcing under the current profile; aim for assembly at JLCPCB or an Indian assembler, subject to HV part availability. Required final outputs: validated schematic, routed PCB, 3D view, MPN BOM with DNPs, Gerbers, drill/slot data, centroid file, assembly drawing and complete assumptions/substitutions register. None exists yet. No zero-error ERC/DRC claim has been made.
Firmware-Relevant Hardware Requirements
Validate alternate-function compatibility of the proposed LaunchPad map. Firmware must coordinate ADC scaling/reference, CMPSS protections, communication direction, display control and PWM enable. An independent hardware shutdown path and driver-specific safe state must be defined; firmware alone must not be assumed to ensure safety.
Physical Design Expectations
Preserve uploaded floorplan where feasible, but safety clearances and electrical ratings override geometry. Original requirements for <=60 mm ADC routes from distant voltage lanes to LaunchPad sockets cannot all be met as drawn; filter positions or the floorplan must change. Derive insulation separately for each domain pair, not as a blanket clearance between all divider nodes. Slots do not by themselves establish air clearance.
Important Design Decisions
  1. User-approved revalidation for 400 Vrms line-to-neutral and 1200 VDC replaces the original lower-rated input protection.
  2. Retain the on-board isolated-analog architecture provisionally; final safety selection is not committed.
  3. Retain 10 kohm AC sense resistors provisionally; evaluate 4.02 kohm for the DC channel with the original resistor strings, subject to tolerance, fault and transient analysis.
  4. User places MOVs and fuses at the inverter terminals rather than on the carrier. Their ratings and the residual transient exposure of the sensing taps remain integration requirements; external protection does not establish safe sensing insulation by itself.
  5. No HV footprint placement, routing or manufacturing export before input protection and insulation requirements are resolved.
Assumptions
  • The 400 VAC answer refers to RMS line-to-neutral, as explicitly stated in the preceding question and accepted by the user.
  • The DC source is a battery with bus capacitors, fed directly by MPPT as described by the user. The user confirmed 300 V maximum charging voltage; the requested sensing range extends to 1200 V. Abnormal overvoltage and common-mode voltage to PE/controller ground remain unknown. This source arrangement does not establish whether the bus is floating or earthed.
  • Nominal calculations are not overload or safety qualification.
  • Indoor installation and approximately 235 m altitude are confirmed. Pollution degree, humidity/condensation, temperature, OVC, insulation class, transient environment, earthing and prospective fault currents are not assumed.
  • Provisional DC voltage accuracy target accepted as a starting point: +/-0.5% of reading at 300 V (equivalent to +/-1.5 V), after calibration. This is a design target, not verified performance or a guarantee across the entire 0-1200 V range or temperature range. Suitability for control and protection thresholds remains to be checked. AC accuracy and waveform bandwidth targets remain unspecified.
  • Sensing up to 1200 V does not by itself make the complete inverter or battery system suitable for 1200 V operation. Input circuitry must nevertheless safely accommodate the full specified measurement range if it can be applied continuously.
Change Notes
2026-10-26: Renamed project, recorded confirmed voltages, obtained independent read-only architecture review, identified unsafe baseline protection and divider range, and opened safety-integration questions. No circuitry has been captured or placed. See Voltage Input Validation for calculations and the remaining decision gates.
2026-10-26 clarification: User confirmed galvanically isolated voltage measurement (not insulation monitoring), indoor installation and approximately 770 ft altitude, and located primary MOV/fuse protection at the inverter terminals. DC-link earthing and measurement performance targets remain open.
2026-10-26 DC-range correction: User clarified approximately 300 V battery/capacitor bus, directly fed by MPPT, with 1200 V requested as the sensing maximum only. Earlier references to a confirmed 1200 V operating bus are superseded. User subsequently confirmed 300 V as the maximum battery charging voltage. Abnormal overvoltage and transient limits remain unspecified.
  • Project Overview

  • Intended Use

  • What the Device Should Do

  • Main Features

  • Mechanical System Architecture

  • Electrical System Architecture

  • Hardware Subsystems

  • Interfaces and Connections

  • Power and Runtime Expectations

  • Power Tree and Power Budget

  • Manufacturing and Assembly Expectations

  • Firmware-Relevant Hardware Requirements

  • Physical Design Expectations

  • Important Design Decisions

  • Assumptions

  • Change Notes