This report applies to the common heat-sink-style GM Gen-3 4.8/5.3/6.0 truck smart coil commonly identified as:
ACDelco D585
GM 10457730
Delphi GN10119
Wells C1251
Standard Motor Products UF262
Physical appearance alone is not sufficient because LS coil families use different housings and some online pinouts mix coil types. Verify the molded cavity letters and preferably the part number on the actual coil before wiring.
Four-pin connector pinout
Viewed by the molded cavity letters, not by an assumed left-to-right photo orientation:
Mating connector identifiers reported by MegaManual are GM 12580353 / Delphi 15439568. Connector suppliers may sell these under application descriptions rather than those bare numbers.
Research confirms the D585 pinout: A power ground, B signal ground, C trigger, D switched 12 V. It charges with a >4 V high signal and sparks on the falling edge; start around 3.5 ms dwell at 14 V.
Important finding: firing both coils at every trigger would approach 93% dwell duty at 8000 RPM, so the controller needs alternating cylinder outputs rather than permanently tied triggers. Full details: D585 Coil Research.
I’ll evaluate strategies that work with two potentially identical pickup events—startup wasted spark, trial-and-confirm phasing, crank-acceleration detection, target asymmetry, and adding an index sensor—then rank them by safety and implementation risk.
Startup and Phase IdentificationProblem definition
The Rotax 593 has one VR pickup and appears to produce two crank-reference events per revolution, about 180° apart. If those events are electrically and geometrically identical, the controller knows that one cylinder is approaching its firing position but cannot initially know whether that event belongs to the MAG or PTO cylinder.
This is not a four-stroke cam-phase problem: each two-stroke cylinder fires once per crank revolution. It is a cylinder-label problem caused by two symmetric crank events and two separate single-output coils.
If the targets are truly identical, no passive algorithm can identify MAG versus PTO from the first pulse alone. Additional information must come from target asymmetry, another sensor, store...
Existing MPEM is failed/nonfunctional; the project is a replacement ignition controller, not an add-on to a working stock ignition.
Engine: Rotax type 593, 597 cm³, two-cylinder two-stroke
Bore × stroke: 76.00 × 65.80 mm
Rated maximum-power speed: 8000 ± 100 RPM
Idle: 1500 ± 200 RPM
Factory ignition: CDI function integrated into the MPEM
Published factory timing information
The factory specification is 3.00 mm (0.118 in) piston travel BTDC, verified with a timing light at 3500 RPM with the headlamp on. The service procedure states that advance is unchanged from 3000–4000 RPM, so ±500 RPM during this check does not change the observed mark.
The available factory documents do not publish a complete RPM-versus-advance curve or a degree-BTDC equivalent. Ignition timing is electronic and normally not mechanically adjustable; MPEM programming was the factory adjustment method. Incorrect timing should also prompt a crankshaft-alignment check.
Break-in behavior
For the Summit’s first four operating hours, the MPEM retards timing by 3 degrees from 4500 RPM to maximum RPM. This does not affect the 3500-RPM factory timing check.
Design implication
A faithful replacement curve cannot be reconstructed from published service data alone, and the failed stock MPEM cannot be used for comparison. The only securely sourced operating point is 3.00 mm BTDC at 3500 RPM, with a flat region from 3000–4000 RPM. The safest approximation is to preserve that reference and use a conservative cranking/idle region and high-RPM retard, then validate the replacement controller with a timing light and detonation/temperature monitoring.
Pickup configuration
The engine uses one two-wire variable-reluctance trigger/pickup coil, not one pickup per cylinder.
Table
Item
Factory information
Pickup wires
White/yellow (WH/YL) and blue/yellow (BU/YL)
MPEM connector
11-DC pins 1 and 2
DC resistance
190–300 Ω
Manual-start output
Approximately 0.200–0.350 V AC
Trigger count
One pickup/trigger assembly
The pickup is a low-level bipolar AC source whose amplitude rises with speed. A replacement controller therefore needs a protected VR-sensor conditioner with hysteresis and polarity control; it must not connect directly to a microcontroller input.
Stock magneto and coil arrangement
The stock system has a magneto ignition-generator winding feeding the MPEM and one external dual-output high-voltage coil firing both plugs in a wasted-spark arrangement.
Table
Function
Wiring / specification
Ignition-generator wires
Red (RD) and black/red (BK/RD), connector 11-DB
Generator resistance
11.6–21.6 Ω
Cranking generator output
Approximately 15–30 V AC
Stock coil primary
White/blue (WH/BL) and black (BK), connector 11-DD
Stock coil primary resistance
0.0–0.9 Ω
Stock secondary with caps
17.6–26.4 kΩ
Because a single crank pickup and the original dual-output coil fire the cylinders as a pair, the stock configuration does not provide cylinder-identification information. Two Gen-3 LS coils can still be driven independently as hardware channels, but without another position/index signal they should receive the same spark command (wasted spark). Truly independent cylinder timing requires an added crank/cylinder index or a verified trigger pattern that uniquely identifies each cylinder.
High confidence: engine specification, 3.00 mm BTDC check point, test RPM, pickup resistance/output, wire colors, single pickup, and stock dual-output coil configuration.
Not publicly established: the complete stock MPEM timing curve, trigger edge polarity, exact pickup-to-TDC mechanical angle, and waveform amplitude at operating RPM.
These unresolved facts must be measured before an ignition controller is trusted on a running engine.