Fix Pad Holes 25 and 26


How can I help you?

Explain this part
Write a part description
Describe each pin

Manufacturer Clarification Request
Status: Draft only — not sent externally. Not for fabrication.
Product: HOOYA USB-307B-B-SU, LCSC C309374
Scope: Two mirrored L-shaped shell-mounting openings, identified as pads 25 and 26 in our footprint. These are our CAD pad numbers; please confirm their correspondence to your mechanical features.
Prepared: 2026-10-29
Draft message
To: HOOYA technical support / connector engineering
Subject: USB-307B-B-SU — clarification of recommended PCB L-shaped mounting holes and copper lands
Dear HOOYA Engineering Team,
We are preparing a PCB footprint for USB-307B-B-SU and would like your authoritative recommended PCB geometry before releasing it for manufacture. Our questions concern the two mirrored L-shaped shell-mounting openings shown in the recommended PCB layout, top view.
The drawing under review is 2408200921_HOOYA-USB-307B-B-SU_C309374.pdf. Please confirm that this is the current drawing for the exact USB-307B-B-SU variant and provide the latest revision if not.
Please help resolve the following:
1. Authoritative PCB CAD and coordinate datum
  • Please supply the recommended PCB footprint as dimensionally authoritative DXF/DWG, IPC-2581, native EDA library, or an equivalent fully dimensioned land-pattern drawing. A dimensioned PCB drawing is needed in addition to any connector-body STEP model.
  • Please identify the top-view orientation, mating direction, PCB edge position, origin, units, and coordinate datums.
  • Please identify which shell features correspond to the two mirrored L-shaped PCB openings and confirm that this land pattern applies to USB-307B-B-SU rather than another suffix or mounting variant.
2. Exact vertical placement of both L openings
  • Please dimension each opening relative to an explicit mechanical datum, preferably the rear straight mounting-slot centerline or the locating-hole centerline.
  • Is the full height of each L opening centered on the horizontal reference line used in the recommended PCB drawing? If so, please confirm the dimension and tolerance explicitly.
  • Please give the X/Y coordinates of the contour landmarks or equivalent complete position dimensions, including positional tolerances. The drawing overlay alone is not being treated as a manufacturing measurement.
3. Hole contour, corner radii, and acceptable machining relief
  • Please provide the complete intended contour, including radii at the ends, outside corners, and re-entrant corner of each L.
  • Which radii are mandatory, and what minimum/maximum radii are acceptable for shell-tab insertion?
  • Are cutter-radius fillets or relief features permissible? If so, please specify their locations and maximum envelope; we will not assume dogbones or enlarge the holes without approval.
  • Please provide shell-tab dimensions/tolerances or the minimum required insertion clearance so that the PCB fabricator's achievable routing geometry can be checked against fit.
4. Plated versus unplated construction
  • Should these two L openings be plated through, non-plated, or made using another specified construction?
  • Are the shell tabs intended to be soldered to lands on both PCB faces? Please identify required copper layers, shell/ground connection, and soldering method.
  • If plated, please specify minimum barrel/slot-wall copper thickness and any relevant plating or surface-finish requirements. We are not inferring PCB-hole plating from the connector shell's surface finish.
5. Finished-hole dimensions and tolerances
  • Do the recommended PCB opening dimensions refer to finished openings after plating and surface finish, or to pre-plating drill/router dimensions?
  • Please confirm nominal dimensions and separate size, position, and profile tolerances for the L apertures; please identify any exceptions to general drawing tolerances.
  • Please confirm whether the specified PCB thickness is mandatory, and provide its allowable range and tolerance.
  • If the stated tolerance is not achievable with a standard routed slot process, what manufacturer-approved alternative geometry or tolerance is acceptable? We do not intend to substitute oval openings or overlapping drill hits without explicit approval.
6. Complete copper-land and solder-mask geometry
  • Please provide complete outer copper contours for both lands, including overall height, leg widths, corner/end radii, and position relative to the hole contours.
  • Please confirm required annular copper around the full L shape and whether the same land geometry is required on the top and bottom faces.
  • Please specify solder-mask opening contours or expansion, any mask-defined requirements, and solder-paste apertures or explicit omission of paste, as applicable.
  • Please identify any copper, mask, or mechanical keepouts around the shell openings.
7. Final confirmation for fabrication and assembly
Please provide an annotated drawing or CAD file answering the above and confirm the intended finished geometry. We will obtain separate PCB-fabricator approval of routing capability and tolerances, review its CAM preview, and check a prototype assembly before production release.
Thank you.
Interpretation table for manufacturer confirmation
All entries below are provisional interpretations from the prior drawing investigation, unverified for manufacturer release. They are questions to confirm, not approved specifications.

Table


FeatureProvisional interpretation — please confirm or correct
L opening overall envelope1.20 mm horizontal × 1.60 mm vertical
Width of both legs0.60 mm
Spacing of vertical-leg centerlines8.64 mm
OrientationMirrored, with vertical legs outboard and horizontal legs directed inward
Copper outer width1.54 mm
Copper vertical-leg width1.00 mm
Copper overall height and detailed radiiNot resolved; complete contour requested
Drawing PCB thickness0.60 mm; applicability and tolerance to be confirmed
General PCB-layout tolerance±0.05 mm; scope and exceptions to be confirmed
Vertical centeringAppears centered on a drawing reference line, but no explicit ordinate is established
Plating and finished-size conventionNot established
Optional supporting material
The following diagnostic material can be supplied by the user after review. It has not been sent or attached to an external message.
Internal release holds — not part of the email body
  • Pad 25, left shell opening: blocked on confirmed Y datum, full contour/radii, plating, finished-size convention and associated copper/mask geometry.
  • Pad 26, right shell opening: same blockers, with mirrored geometry to be confirmed.
  • Production output for pads 25 and 26: blocked on complete corrected board exports, PCB-fabricator written acceptance, CAM-preview review and prototype fit check. A mechanical annotation alone will not replace obsolete oval drill definitions.
  • No electrical open-net condition is asserted by this request; these holds concern mechanical fit and fabrication geometry.
  • The footprint, its pad UIDs, and all electrical connectivity remain unchanged by preparation of this document.
  • No manufacturer or fabricator has been contacted, and no approval has been obtained.
  • Draft message

  • 1. Authoritative PCB CAD and coordinate datum

  • 2. Exact vertical placement of both L openings

  • 3. Hole contour, corner radii, and acceptable machining relief

  • 4. Plated versus unplated construction

  • 5. Finished-hole dimensions and tolerances

  • 6. Complete copper-land and solder-mask geometry

  • 7. Final confirmation for fabrication and assembly

  • Interpretation table for manufacturer confirmation

  • Optional supporting material

  • Internal release holds — not part of the email body