U.FL Connector Guide
U.FL-R-SMT-1(01) Application and Usage Guide
Table
| Parameter | Value | Classification / practical meaning |
|---|---|---|
| Nominal characteristic impedance | 50 Ω | Transmission-line target, not a resistor value to add across the connector. |
| Frequency range, stored catalog | DC to 6 GHz | Catalog operating range; current exact-part page lists 8 GHz maximum as noted above. |
| Operating temperature, stored catalog | −40 to +90 °C | Catalog operating range, not a junction-temperature rating; current exact-part page lists +105 °C as noted above. |
| Operating humidity, stored catalog | 90% RH maximum | Catalog environmental operating limit. |
| Continuous operating voltage | Unverified | No separate voltage rating was identified in the retrieved catalog ratings table; do not substitute the withstand-test voltage. |
| Continuous operating current / RF power rating | Unverified | No separate operating-current rating identified in the retrieved catalog. The 10 mA maximum is a contact-resistance test condition, not an allowable load-current rating. No RF wattage is claimed. |
| Dielectric withstand | 200 V AC for 1 minute | Qualification/test requirement: no flashover or insulation breakdown. Not a continuous operating-voltage limit. |
| Initial contact resistance | Center ≤20 mΩ; outer ≤10 mΩ | Catalog specified maxima under the contact-resistance test conditions. |
| Package / interface | Straight SMT U.FL receptacle; one coaxial position | Three solder terminals in this Flux part: one signal and two grounds. Hirose; library pin inspection. |
| Pitch | Not a uniform-pitch header | Use the released recommended land pattern. Exact pad dimensions, spacing, and tolerances were not reliably verified during this research. |
| Receptacle occupied area | 7.7 mm² | Catalog mounting-area figure; not the complete courtyard or cable-access clearance. |
| Mated height | Plug-dependent | U.FL-LP(V)-040HF: 1.9 mm nominal / 2.0 mm maximum; U.FL-LP-040HF, -066HF, or -068HF: 2.4 mm nominal / 2.5 mm maximum. Specify the cable plug before reserving enclosure height. |
| Mating/unmating durability | 30 cycles | Listed on the current exact-part page; not a connector intended for frequent user cycling. Hirose |
| Catalog reflow-profile peak | 250 °C maximum for 10 seconds | Assembly-process limit from the retrieved catalog, not operating temperature. Verify the entire current process profile before production. |
| Semiconductor-style absolute maximum ratings | Not identified as a separate table | Connector specifications use operating ratings, test requirements, and process limits. Do not relabel qualification-test values as absolute maximum operating ratings. |
SIN; that name does not imply the connector is input-only. Confirm physical pad-to-contact mapping against Hirose's released drawing before production or substitution.Table
| Pin Number | Pin Name | Description | Best Practice |
|---|---|---|---|
| 1 | GND | One outer-contact / shell solder terminal in the library model | Tie directly to RF ground; provide a short, low-inductance connection to the reference plane. |
| 2 | SIN | Center-contact RF signal terminal in the library model | Connect to the radio's matched RF port through a 50 Ω controlled-impedance line. No pull-up or pull-down is required by the connector. |
| 3 | GND | Second outer-contact / shell solder terminal in the library model | Tie to the same RF ground as pin 1; do not leave this pad electrically floating. |
Text
Radio RF port → radio-specific matching/filter network → 50 Ω PCB transmission line → pin 2 / SIN → compatible U.FL cable plug → 50 Ω coax → antenna RF ground / reference plane → pins 1 and 3 / GND → coax shield
Table
| Manufacturer / Part | Verified basis | Compatibility classification | Substitution action |
|---|---|---|---|
| Amphenol RF A-1JB in Flux | Amphenol identifies an AMC straight SMT 50 Ω jack and explicitly states AMC compatibility with Hirose U.FL. Manufacturer page | Mating-interface compatible; PCB footprint and numeric pin compatibility not verified. Not approved here as a drop-in. | The found Flux model has 4 terminals, versus 3 for this Hirose model; compare ground-pad arrangement and the recommended PCB pattern. Amphenol's web page and customer drawing have differing temperature listings, so confirm the applicable specification rather than transferring Hirose's rating. |
| I-PEX 20279-001E-03 / MHF I | The manufacturer lists it as the recommended 3-pad MHF I receptacle and as the alternative to the older 20279-001E-01 packaging variant. Manufacturer page | Functionally similar; cross-brand mating, footprint, and numeric pin compatibility not verified in this research. | Compare the released I-PEX and Hirose drawings and qualify the actual cable assembly. Do not choose 20279-001E-01 for a new design merely because it appears in older references: I-PEX lists it under “Plan to EOL.” |
I-PEX P/N 20279-001E-03 in its MPN field, but links a Taoglas RECE.20279.001E.01 datasheet. Treat that as an unverified alias/model, not a validated exact I-PEX part or proof of footprint compatibility.Table
| Attribute | Details |
|---|---|
| Primary Distributors | Exact-part listings found at LCSC, C598199 and TME. For PCB assembly, JLCPCB C598199 identifies this exact MPN as an Extended part. DigiKey's exact-part SKU is reported by distributor aggregation, but its direct listing and Mouser's exact-MPN listing were not independently verified here; check them before ordering. A listing does not establish manufacturer authorization. |
| Packaging Options | (01): 100 pieces per pack. The catalog also lists (60): 4,000 pieces per reel and (80): 10,000 pieces per reel. Those are different full ordering codes; do not describe (01) as a factory tape-and-reel code. |
| Standard MOQ | Hirose catalog sales unit for (01): one 100-piece pack. Distributor repacking can differ: TME's exact-part listing states minimum 1 piece, multiple 1. The reel quantities above apply to their respective suffixes, not (01). TME listing |
| Sourcing Advice | Prefer Hirose-franchised distributors verified through the manufacturer's current channel list; request traceability and avoid untraceable marketplace stock. Confirm the full code U.FL-R-SMT-1(01) and Hirose identifier CL0331-0472-2-01, not merely “U.FL.” Verify pack type, feeder/repacking arrangements, and substitutions with the assembler. Do not infer a reel quantity from an assembly-service field labeled “Full Reel.” Check live stock and lead times when ordering; no availability guarantee is made here. Hirose |
1=GND, 2=SIN, 3=GND; A-1JB and the I-PEX alias search results. These are library-model observations, not manufacturer numbering or dimensional validation.1. Quick Specifications
2. Pinout & Connections
3. Standard Application Circuit
4. PCB Layout & Routing Guidelines
5. Common Pitfalls / Things to Watch Out For
6. Popular Alternatives & Equivalents
7. Sourcing & Purchasing Guide
Sources