9.2VC Clamp 21.8A Ipp TVS DIODE SOD-123FL
The SMF5.0A is a unidirectional Transient Voltage Suppressor (TVS) diode designed to protect sensitive electronic circuits from electrostatic discharge (ESD), lightning surges, and other transient overvoltage events. It is commonly used on 5V power rails, USB VBUS lines, DC inputs, and general-purpose power protection applications. The device comes in a compact surface-mount SOD-123FL/SMF package suitable for space-constrained PCB designs.
Key Features
5V reverse standoff voltage (VRWM)
200W peak pulse power dissipation (10/1000µs waveform)
Fast response time for transient suppression
Low clamping voltage (~9.2V max)
Unidirectional TVS protection
Excellent ESD and surge protection capability
Compact SOD-123FL / SMF surface-mount package
Low leakage current
Operating temperature up to +150°C
RoHS compliant and halogen-free variants available
Published the metadata-only repaired fork: terminal 1 = Cathode, 2 = Anode, preserving Passive pin types, pin numbers, symbol and footprint; the original part and charger board were untouched.
Part UID:5de499b5-b62f-41d1-afd4-210e1b83d3ef · Published version:b01fb0f1-bfcd-46f9-adc2-4bbd139dd1a7.
Saved roles are verified; Terminal Type is not a supported property API, publication metadata/history are inconsistent, and empty part/ERC check results do not prove the consuming-board warning cleared—no warning was waived.
The Liown SMF5.0A is a unidirectional silicon-avalanche transient-voltage-suppressor (TVS) diode for shunting short overvoltage events away from a protected 5 V-class rail. Its most common use is across an exposed DC input, VCC bus, or connector power line, with the cathode on the positive rail and the anode connected to the local surge-return ground.
Exact project variant: Liown Semiconductor SMF5.0A, LCSC C2990427, SOD-123FL. The authoritative Liown document is titled SMF Series Datasheet, revision V2; no publication date is printed in the document.
1. Quick Specifications
The ratings below apply at the datasheet test conditions; transient ratings are not continuous operating ratings.
Table
Parameter
Classification
Value / Condition
Reverse stand-off voltage, VRWM
Normal maximum continuous reverse voltage
5 V
Breakdown voltage, VBR
Electrical characteristic
6.4 V min, 7.0 V max at IT = 10 mA
Maximum clamping voltage, VC
Transient electrical characteristic
9.2 V at IPP
Peak pulse current, IPP
Absolute transient rating
21.8 A, associated with the specified 10/1000 µs pulse
Peak pulse power, PPPM
Absolute transient rating
200 W minimum, 10/1000 µs waveform
Peak pulse power, short surge
Absolute transient rating
1000 W minimum, 8/20 µs waveform
Reverse leakage, IR
Electrical characteristic
500 µA max at VR = 5 V
Steady-state power dissipation
Thermal rating
1.0 W at TL = 75 °C; do not confuse with the 200 W pulse rating
Thermal resistance, junction-to-lead
Thermal characteristic
100 °C/W typical
Thermal resistance, junction-to-ambient
Thermal characteristic
220 °C/W typical
Junction and storage temperature
Absolute rating
−55 °C to +150 °C
Package
Mechanical
SOD-123FL, surface mount
Body dimensions
Mechanical
A: 3.50–3.90 mm; B: 2.60–3.00 mm; height C: 0.75–1.10 mm
Compliance stated by Liown
Qualification
IEC 61000-4-2 15 kV air / 8 kV contact, RoHS, UL 94V-0, MSL 1
The SMF5.0A electrical row verifies VRWM, VBR, IT, VC, IPP, and IR. The pulse, thermal, and temperature ratings are listed in the maximum-ratings table. The package dimensions and height are specified in the SOD-123FL mechanical section.
Selection warning: A 5 V stand-off rating means the protected rail should not normally exceed 5 V, including tolerance, ripple, hot-plug overshoot, and charging-source variation. Because the device may clamp as high as 9.2 V at its rated pulse current, confirm that downstream components can tolerate the residual clamped voltage and any additional PCB-inductance overshoot.
2. Pinout & Connections
The current project symbol exposes terminals 1 and 2, but the Liown datasheet identifies polarity by the cathode band rather than publishing an explicit numeric pin map. Verify the footprint pad numbering against the cathode-band orientation before production.
Table
Pin Number
Pin Name
Description
Best Practice
1*
Cathode (K), provisional mapping
Positive side during normal reverse-biased protection operation; physically identified by the cathode marking/band.
Connect to the protected positive rail only after confirming that project pad 1 is the banded end. Keep the path from connector/source to cathode short and wide.
2*
Anode (A), provisional mapping
Surge-return terminal.
Connect directly to the local ground/negative return only after confirming the pad mapping. Use the shortest practical, low-inductance path and do not route surge current through sensitive logic ground traces.
*The functional polarity is verified by the cathode marking, but numeric pad-to-polarity assignment is not explicitly stated in the Liown datasheet. The 1 = cathode / 2 = anode mapping is consistent with the verified PANJIT SOD-123FL alternative, but remains provisional for this Liown library part until the footprint is checked against the banded package end.
3. Standard Application Circuit
Typical 5 V power-input protection
Text
External +5 V / VBUS ─────┬──────── Protected +5 V rail
│
K ┌──┴──┐
│ TVS │ SMF5.0A
A └──┬──┘
│
External return / GND ────┴──────── Local power ground
Connect the cathode/banded end to the positive rail and the anode to ground. In normal operation the diode is reverse-biased; during a positive transient it avalanches and diverts current to ground.
Place the TVS between the transient source and the protected circuit, ideally immediately behind the connector or cable entry point. The protected circuitry should branch after the TVS connection rather than routing past the device and returning through a long stub.
No bias resistor, pull-up, or decoupling capacitor is required for the TVS itself. Normal rail bulk and high-frequency decoupling may still be needed for the protected load, but those capacitors do not replace the TVS.
If the source can deliver sustained fault current after the TVS conducts, coordinate the TVS with an upstream fuse, resettable fuse, current limiter, or source protection. A TVS is designed primarily for transient energy, not indefinite overvoltage.
The Liown datasheet identifies I/O interfaces, VCC buses, portable devices, business machines, and power supplies as intended application areas.
Suitability limits
USB VBUS: electrically usable for robust 5 V VBUS surge protection when the system can tolerate the 5 V stand-off leakage and up-to-9.2 V specified clamp. It is not a low-capacitance USB D+/D− data-line protector and should not be placed directly on high-speed data pairs.
3.3 V rails: the part will remain off through ordinary 3.3 V operation, but its 6.4 V minimum breakdown may allow excessive voltage for many 3.3 V ICs. Select a lower-voltage protector when the downstream absolute maximum requires tighter clamping.
Negative transients: as a unidirectional TVS, negative excursions are limited by forward conduction rather than avalanche behavior. Check system current paths and ground offsets if negative surge testing is required.
4. PCB Layout & Routing Guidelines
Place it at the entry point. The TVS should be the first shunt device encountered by the incoming transient, before long traces or sensitive loads.
Minimize the surge loop. Keep the connector-to-cathode and anode-to-return paths short, direct, and free of narrow neck-downs. Parasitic inductance adds an L·di/dt overshoot above the datasheet clamping voltage.
Use adequate copper for the pulse path. The 21.8 A value is a short transient, not a continuous-current trace requirement, but both terminals should connect through broad copper rather than thin signal traces. Avoid thermal-relief spokes on surge-current pads when assembly and plane-connect rules permit a solid connection.
Keep surge ground separate from sensitive return routing. Connect the anode to the connector/power-return region with a low-impedance path; do not force surge current through MCU, ADC, oscillator, or communication-interface ground paths.
Use the manufacturer land pattern. The Liown datasheet includes a recommended SOD-123FL solder-pad drawing, but its numeric pad callouts were not extractable from the available document text; validate the library footprint visually against the drawing before release.
5. Common Pitfalls / Things to Watch Out For
Reversing the diode. If the cathode/banded end is connected to ground on a positive rail, the unidirectional device becomes forward-biased and can short the supply. Confirm the physical band, symbol orientation, and footprint pad mapping.
Treating 200 W as a continuous rating. The 200 W specification applies to a defined 10/1000 µs pulse; the datasheet's steady-state rating is only 1.0 W at TL = 75 °C. Also avoid selecting solely by VRWM: the protected IC must survive the 9.2 V maximum clamp plus layout-induced overshoot.
6. Popular Alternatives & Equivalents
Always compare the exact ordering code, leakage, qualification, temperature range, land pattern, and marking before substitution.
Table
Alternative
Manufacturer
Compatibility
Key Notes
SMF5.0A_R1_00001
PANJIT
Pin-compatible and nominally footprint-compatible SOD-123FL replacement
5 V VRWM, 6.4–7.0 V VBR, 9.2 V VC at 21.7 A, 200 W; cathode identified by color band. Confirm the exact land pattern against the Liown footprint.
SMF5.0A / SMF5.0A-T13
Littelfuse
Functionally and package compatible; expected SOD-123FL footprint compatibility, but verify pad geometry
Official product data specifies 5 V VRWM, 6.4–7.0 V VBR, 9.2 V clamp, 21.7 A, 200 W. The unsuffixed part is 7-inch tape-and-reel; -T13 is 13-inch tape-and-reel.
SMF5.0A-TP
Micro Commercial Components (MCC)
Functionally and package compatible; verify footprint and ordering suffix
SOD-123FL 200 W unidirectional TVS with the same nominal 5 V / 9.2 V / 21.7 A class. The -TP suffix identifies MCC tape-and-reel ordering.
Not a universal “drop-in” statement: SMF5.0A parts from different manufacturers commonly share the same nominal electrical class, but leakage can differ (for example, Liown specifies 500 µA while some alternatives specify 400 µA), and environmental or automotive qualification may differ.
7. Sourcing & Purchasing Guide
Table
Attribute
Details
Primary Distributors
The exact Liown part is listed by LCSC/JLCPCB as C2990427. Equivalent manufacturer versions are commonly available through DigiKey, Mouser, Arrow, Verical, and manufacturer-authorized channels; confirm the listed manufacturer rather than buying only by the generic SMF5.0A string.
Packaging Options
Exact Liown listing: tape-and-reel, SOD-123FL. JLCPCB identifies a 3,000-piece full reel. Distributor cut-tape availability depends on the seller.
Standard MOQ
JLCPCB PCBA parts listing: 1 piece minimum for library/assembly purchasing; 3,000 pieces per full reel. Distributor cut tape is typically orderable from one piece where stocked.
Current listing snapshot
On September 29, 2026, JLCPCB showed 1,664 pieces in stock, MSL 1, with quantity pricing beginning at US$0.0328 for one piece. Stock and price are volatile and must be rechecked before ordering.
Sourcing Advice
Prefer franchised or traceable distributors. Avoid unverified marketplace stock for surge-protection components, because die size and pulse-energy capability cannot be confirmed visually. Confirm manufacturer, exact suffix, package, reel size, polarity marking, and compliance on the purchase order. Do not substitute a bidirectional SMF5.0CA without reviewing negative-transient behavior.
Sources
Liown Semiconductor — official SMF series product table and specification preview. This page contains the SMF5.0A row and links to the manufacturer specification; the cited V2 document does not state a publication date: https://www.liownsemi.com/list-98.html
Verified from the Liown V2 datasheet: electrical table, pulse ratings, thermal ratings, temperature limits, SOD-123FL dimensions, cathode marking, stated applications, and IEC/RoHS/MSL claims.
The Liown datasheet contains a recommended solder-pad drawing, but numeric pad dimensions were not machine-extractable; footprint geometry therefore requires visual drawing comparison before manufacturing.
The Liown datasheet does not explicitly map numeric terminal numbers to anode/cathode. Functional polarity is verified by the cathode band; the project footprint's pad-number mapping must be checked separately.