SHT40 Source Repair Blocker


Authorized R4 D exact SHT source repair
Existing SHT40-AD1B-R2/C2909890 has erroneous EP terminal5 and physical pad. Inspect source permissions; if read-only create/import corrected exact source, not a differently named variant. Verified USER map ONLY four terminals1SDA bidirectional,2SCL input,3VDD power in,4VSS Ground, no EP. Actual required footprint Sensirion_DFN-4_1.5x1.5mm_P0.8mm_SHT4x_NoCentralPad at https://gitlab.com/kicad/libraries/kicad-footprints/-/raw/master/Sensor_Humidity.pretty/Sensirion_DFN-4_1.5x1.5mm_P0.8mm_SHT4x_NoCentralPad.kicad_mod ; retrieve before use, no guessing. Remove fictitious EP terminal/copper/mask/paste via actual four-land asset. Preserve exact MPN/manufacturer. Publish corrected source before adoption; report UID/version/full URL and readback four terminals/four distinct pads/no central copper or stencil. Missing3D disclose separately, does not block verified copper/electrical fix. No carrier edits. One bounded attempt if unsupported return concrete blocker. Write source correction evidence file.
I’ll check source access, retrieve the specified four-land footprint, and create a corrected exact-MPN source if the existing library part is read-only. I’ll verify its terminals and copper before reporting a published version; no carrier edits.
Blocked: the existing source is read-only, and the exact-MPN symbol-file creation attempt was rejected, so no corrected UID or version was published. I confirmed the fictitious EP terminal and central copper/mask/paste pad, retrieved the required four-land asset, and filed a part-quality report; no carrier edits were made.
Evidence and the concrete continuation requirement are recorded in sht40-source-correction-evidence.

SHT40-AD1B-R2 Application and Usage Guide
The Sensirion SHT40-AD1B-R2 is a factory-calibrated digital relative-humidity and temperature sensor with an I²C interface, fixed 7-bit address 0x44, and a compact open-cavity DFN package. Its common use is low-power ambient monitoring in battery-operated data loggers, HVAC controls, and connected environmental sensors; correct thermal isolation and contamination control are as important as the electrical connections. Sensirion product overview
1. Quick Specifications

Table


ParameterClassificationValue / conditions
Supply voltage, VDDOperating electrical specification1.08–3.6 V; 3.3 V typical. Not 5 V tolerant.
Voltage on any pinAbsolute maximumVSS −0.3 V to VDD +0.3 V. These are stress limits, not valid logic levels.
Separate absolute-maximum VDD ratingNot specified separatelyThe reviewed absolute-maximum table does not provide a separate numerical VDD rating; do not invent a 4 V allowance. Keep the supply within its 3.6 V operating maximum.
Operating temperatureOperating range−40 to +125°C.
Humidity measurement rangeOperating range0–100% RH, per Sensirion SHT40 product specifications. This is not a constant-accuracy guarantee over the entire range.
Normal recommended environmental conditionsRecommended conditions5–60°C and 20–80% RH; distinguish normal conditions from the extended operating envelope.
Storage temperatureAbsolute-maximum table−40 to +150°C. This is a stress range, not a recommended storage or packaging procedure.
RH accuracyTypical sensor specification±1.8% RH; use the datasheet accuracy curves for humidity and temperature dependence, rather than treating this as a full-range maximum.
Temperature accuracyTypical sensor specification±0.2°C; use the temperature-dependent accuracy curve for the required operating point.
Idle current, heater offTypical / maximum0.08 µA typical at 25°C; 1.0 µA maximum at 25°C and 3.4 µA maximum at 125°C.
Measurement current, heater offTypical / maximum320 µA typical, 500 µA maximum.
Average current at one measurement/s, heater offTypical; mode-dependent2.2 µA high repeatability; 1.2 µA medium; 0.4 µA low. The often-quoted 0.4 µA is not the high-precision measurement-mode budget.
Heater current, nominal 200 / 110 / 20 mW settingsTypical / maximum60 / 33 / 6 mA typical; 100 / 55 / 10 mA maximum, respectively. Do not size the supply solely from the microampere measurement current.
PackagePhysical specificationOpen-cavity four-pin DFN, with a separate exposed die pad; nominal size 1.5 × 1.5 × 0.5 mm.
Pin/pad pitchUnverified numerical dimensionA numerical pitch was not verifiable from the retrieved drawing evidence. Use the manufacturer's dimensioned package and land-pattern drawings, Figures 15 and 17, before creating a footprint; do not infer pitch from overall body size.
InterfaceOperating featureI²C, including Fast-mode Plus; timing is referred to NXP UM10204. Pull-up selection must suit the actual bus load and speed.
Factory reel quantityOrdering specificationR2: 2,500 pieces, manufacturer material number 3.000.465.
Accuracy clarification: ±1.0% RH and ±0.1°C are not the SHT40 specifications. Do not copy higher-accuracy SHT45 family headline figures into an SHT40 BOM or product claim.
2. Pinout & Connections
Pin numbering below follows the manufacturer's assignment; check the transparent top-view orientation rather than mirroring a bottom-view footprint.

Table


Pin NumberPin NameDescriptionBest Practice
1SDABidirectional serial dataConnect to MCU I²C SDA. Provide an external pull-up to the sensor-compatible supply; the reference circuit uses 10 kΩ. Do not pull up to 5 V.
2SCLSerial clock inputConnect to MCU I²C SCL. Provide a pull-up; the reference circuit uses 10 kΩ. Validate the rise time for the selected bus speed.
3VDDSensor supplyConnect to a regulated rail within 1.08–3.6 V. Place a 100 nF ceramic capacitor directly between VDD and VSS.
4VSSGroundTie to system GND with a short local return for the decoupling capacitor.
Exposed die pad, not a fifth signal pinDie pad / EPNot directly connected to any numbered pin internallyFollow the manufacturer's land pattern. Do not use it as a substitute for pin 4. A local GND connection may be chosen as an engineering implementation, but the retrieved evidence does not establish a mandatory die-pad-to-GND connection.
The four signal-pin assignments, reference passive values, and die-pad isolation are manufacturer-derived.
3. Standard Application Circuit
SHT40 I²C wiring for a 3.3 V microcontroller
Use the manufacturer's minimal circuit: one 100 nF decoupling capacitor and two 10 kΩ I²C pull-up resistors.

Table


Connection / componentWiring
U1 pin 3, VDD3.3 V supply
U1 pin 4, VSSGND
C1, 100 nF ceramicBetween U1 pins 3 and 4, immediately beside the sensor
U1 pin 1, SDAMCU SDA; R1 = 10 kΩ from SDA to 3.3 V
U1 pin 2, SCLMCU SCL; R2 = 10 kΩ from SCL to 3.3 V
Implementation recommendations, not additional mandatory datasheet parts: choose an X7R or X5R capacitor with a voltage rating above the rail; configure the MCU for I²C rather than push-pull GPIO signaling; and account for pull-ups already fitted elsewhere on the bus. Start bring-up at 100 kHz on a short PCB bus, then confirm rise time with an oscilloscope before increasing speed. The reference 10 kΩ values are not a universal prescription for a long cable or Fast-mode Plus bus.
A 5 V host requires a compliant lower-voltage sensor supply and, unless its I²C interface is explicitly compatible with lower-voltage pull-ups, a suitable bidirectional I²C level translator. The sensor's pin stress ceiling tracks VDD, so a 5 V pull-up remains unsafe even when the sensor itself is powered at 3.3 V.
First measurement and data integrity
  1. Address the device at 7-bit 0x44. This exact ordering code has a fixed address, not an address-select pin.
  2. Write command 0xFD for a high-repeatability temperature-plus-humidity measurement.
  3. Wait at least the 8.3 ms maximum conversion time; a 10 ms wait is a practical firmware margin.
  4. Read six bytes: temperature MSB, temperature LSB, temperature CRC, RH MSB, RH LSB, RH CRC. Validate both CRCs before accepting a sample.
  5. CRC parameters are polynomial 0x31, initialization 0xFF, no input/output reflection, final XOR 0x00, applied separately to each two-byte measurement. Use the manufacturer's output-conversion implementation or datasheet Section 4.6 rather than reusing an unrelated humidity sensor's formula.
Optional heater
Leave the heater inactive for ordinary ambient measurements. If using it to address condensation or contamination, allow for the selected setting's peak current and rail droop; the strongest setting reaches 100 mA maximum. Respect 10% maximum lifetime heater duty cycle, ambient temperature below 65°C, and total sensor temperature not exceeding 125°C. Sensor accuracy specifications do not apply during heater operation; resume ambient sampling after thermal recovery.
4. PCB Layout & Routing Guidelines
  • Close the decoupling loop locally: place C1 next to VDD/VSS, with short supply and return connections. This implements the manufacturer's 100 nF reference circuit without routing its return through a distant connector.
  • Measure ambient air, not the PCB temperature: place the sensor away from processors, regulators, charging circuits, displays, and heated airflow. Use a board-edge sensor island, isolation slots, or a flex connection where needed; minimize unnecessary copper carrying heat into the sensor area. Thermal relief here means thermal isolation from heat sources, not adding a heat-spreading plane. Sensirion design guide
  • Preserve air access and the proper land pattern: expose the opening to representative ambient air with minimal enclosure dead volume. Keep coating, adhesive, flux residue, and potting material out of the sensing opening. Use manufacturer land-pattern dimensions, rather than a generic DFN footprint chosen only by package name. Sensirion handling instructions
  • Route SDA and SCL as ordinary single-ended I²C signals: keep them short and away from switching nodes. They are not a differential pair and do not require differential-impedance routing. Verify bus capacitance and pull-up rise time against the selected I²C mode; maintain electrical return continuity even when reducing copper for thermal isolation.
  • Size VDD/GND for heater operation if enabled: evaluate trace resistance and regulator transient capability for up to 100 mA, not only the measurement current. No universal trace width is specified here: copper thickness, length, voltage-drop target, and thermal-isolation needs determine it. Keep the sensor supply/return adequate while avoiding an unnecessary thermal bridge to hot power circuitry.
5. Common Pitfalls / Things to Watch Out For
  1. Incorrect power or I²C integration. Connecting VDD or SDA/SCL pull-ups to 5 V violates the intended operating envelope; omitting pull-ups or assuming 10 kΩ works at every speed causes communications failures. Use a compatible supply, both pull-ups, and measured rise-time validation. Budget heater current separately if enabled.
  2. Treating the sensor like a sealed IC. Mounting it beside a heat source, washing the assembled board, or coating the sensor opening can bias measurements or damage the sensing element. Use thermal isolation, no-clean soldering practices, suitable ventilation, and a protected sensing opening during processing. Sensirion design guide Sensirion handling instructions
No cross-manufacturer drop-in replacement was verified in this research. The two established alternatives below provide the relevant measurement functions but require PCB and firmware changes; neither is pin-compatible or footprint-compatible with SHT40-AD1B-R2. Their different package dimensions and pin counts establish the physical incompatibility.

Table


AlternativeManufacturerCompatibility classificationSelection and migration guidance
HDC3020DEFR / HDC3020Texas InstrumentsFunctionally similar only. Not pin-compatible; not footprint-compatible.I²C RH/temperature sensor with heater. Uses an eight-pin 2.50 × 2.50 mm WSON package and 1.62–5.5 V supply. Redesign the footprint and pin connections; use the HDC3020-specific driver and validate timing, commands, and data conversion.
BME280Bosch SensortecFunctionally similar only. Not pin-compatible; not footprint-compatible.Combined humidity, temperature, and pressure sensor with I²C/SPI. Uses an eight-pad 2.50 × 2.50 mm LGA package. VDD is 1.71–3.6 V; VDDIO is 1.2–3.6 V. Its −40 to +85°C operating range does not cover the SHT40's full upper-temperature range. Redesign the board and use Bosch-specific register access and compensation software; do not substitute the SHT40 command/CRC workflow.
These links lead to manufacturer product pages, not Flux library entries. Because neither option is a verified drop-in replacement, no claim of library-verified drop-in availability is made. Stock and pricing were not verified for the alternatives.
7. Sourcing & Purchasing Guide

Table


AttributeDetails
Primary DistributorsDigiKey and Mouser are listed in Sensirion's channel-partner directory. Future Electronics lists the exact SHT40-AD1B-R2. JLCPCB listing C2909890 provides an assembly sourcing reference; its presence does not establish franchised-distributor status.
Packaging OptionsManufacturer R2 tape-and-reel packaging: 2,500 pieces. Cut-tape and re-reel options depend on the distributor's exact listing; current small-quantity packaging was not verified here.
Standard MOQA factory R2 reel contains 2,500 pieces. The reviewed Future Electronics listing specifies MOQ 2,500 and order multiple 2,500. This is distributor-specific, not a universal MOQ; 1-piece cut-tape MOQ remains unverified.
Sourcing AdviceBuy through the manufacturer's listed channel partners and request traceable stock. Avoid relying on non-authorized marketplace claims, especially where counterfeit, storage damage, or chemical exposure cannot be excluded. Match the exact SHT40-AD1B-R2 ordering code and material number 3.000.465; do not silently substitute an address, protection, accuracy, or reel variant. Confirm packaging, date code, current stock, and lead time at purchase.
Verification limits: the project's originally attached datasheet URL could not be downloaded, so this guide uses a manufacturer-hosted Version 7.3 source instead. Numeric pad pitch, a separately specified absolute-maximum VDD rating, one-piece purchasing MOQ, and live inventory/prices were not verified. Distributor catalog summaries are not used to override manufacturer electrical specifications. This document is integration guidance, not an audit of the current Flux footprint or its five pads; no schematic, footprint, or component properties were changed.
Sources
  • Sensirion, Datasheet – SHT4x, Version 7.3, June 2026. Sections 1–5 and 10: application circuit, sensor/electrical specifications, absolute maximum ratings, protocol, heater, package/pin assignment, and ordering. Manufacturer datasheet. Revision provenance:
  • Sensirion, SHT40 product catalog. Manufacturer overview and operating humidity range. Product page; page revision date not stated.
  • Sensirion, Design Guide for Humidity and Temperature Sensors, Version 2, March 2024. Thermal isolation, air access, housing and PCB design. Manufacturer design guide.
  • Sensirion, Handling Instructions for SHTxx, Version 8.3, February 2024. Contamination, soldering, cleaning, coating, and storage practices. Manufacturer handling instructions.
  • Sensirion, Channel Partners. Distributor authorization reference. Manufacturer directory; page revision date not stated.
  • Texas Instruments, HDC302x datasheet, Rev. D, July 2024. Alternative sensor package and recommended supply range. Manufacturer datasheet and product page.
  • Bosch Sensortec, BME280 datasheet, Rev. 1.24, February 2024, BST-BME280-DS001-24. Alternative sensor package, interfaces, supply rails, and temperature range. Manufacturer datasheet and product page.
  • Future Electronics, SHT40-AD1B-R2 listing. Exact-part reel MOQ and order multiples. Distributor listing; dynamic purchasing data must be rechecked.
  • JLCPCB, SHT40-AD1B-R2, C2909890. Assembly catalog reference. Supplier listing; live stock and pricing not verified.
Research checked: October 6, 2026.
  • 1. Quick Specifications

  • 2. Pinout & Connections

  • 3. Standard Application Circuit

  • SHT40 I²C wiring for a 3.3 V microcontroller

  • First measurement and data integrity

  • Optional heater

  • 4. PCB Layout & Routing Guidelines

  • 5. Common Pitfalls / Things to Watch Out For

  • 6. Popular Alternatives & Equivalents

  • 7. Sourcing & Purchasing Guide

  • Sources