SD-119 Footprint Audit
Reconcile the current 15-pin part with the official drawing and correct symbol, terminal definitions, pad mappings, and land geometry.
Independently verify the corrected component and document any remaining limitations.
Table
| Assigned item | Status | Evidence / blocker |
|---|---|---|
| Current-state and source research | Completed with citation limitation | Manufacturer PDF read manually; citation service remains evidence_pending. |
| Terminal identities, numbering and mapping | Completed | Fifteen existing terminal UIDs retained; symbol readback exposes numbers 1–15 exactly once. No terminals or nets were created or deleted in this repair pass. |
| Electrical types and symbol arrangement | Completed | All fifteen Passive; eleven Contacts left, four Shield contacts right; unique group orders; overlapping custom pin positions removed; parametric-v1 image shows separate contacts. |
| Part metadata | Completed | Description identifies standard SD push-pull socket, CD/WP, fifteen terminals; Part Type Connector, Connector Type Memory Connectors, Mount Through Hole, working Datasheet URL. |
| Direct source-pad geometry rules | Completed at stored-rule/readback level | All fifteen pads active; positions, copper dimensions, drilled-pad types and hole offsets read back. No !important overrides. Physical export still unverified. |
| Footprint source file synchronization | Completed as asset storage; activation failed | Same asset UID now stores revised 15-pad source. However, subsequent footprint asset.payload and Silk Shapes still show the old source. Stored source and resolved layout are inconsistent. |
| Silkscreen envelope correction | Failed to activate | Revised source contains clearance-adjusted lines; current resolved silk remains the old geometry. Direct mutation of the generated silk UID was rejected as unknown. |
| Mechanical exclusion regions | Failed / blocked after focused investigation | No exclusions added: exact polygon boundaries, hatch-to-region association, and vertical clearance remain unresolved. See focused final review below. Silk is not a keepout. |
| Fresh component checks | Completed | Five component-review categories Success, zero reported errors/warnings, reviewedAt 2026-10-22T16:47:05.544Z. |
| Manufacturing drill/mask verification | Failed / blocked | Part project has no top-level board layout; native KiCad export rejected its footprint UID. Part layout image omits pads. Structured footprint parser omits drill/layer data despite explicit source clauses. |
| 3D model dimensional review | Unattempted | Existing STEP/model placement retained, not dimensionally revalidated. |
| Publication | Unattempted | No publication or duplicate replacement part created. |
b596be554d835c5d5df4883010492e5df1d0ed608236d1baca25ec9455f47d8b. Physical page 2 contains the mechanical drawing; physical page 3 contains the recommended PCB top view, Details A/B and terminal table. Product page.commentFileId-b6f6a5683cc3012d4d0126c65299f2634f9d9d018ba5ee1cd956f418de9e822b
commentFileId-83515868a191d3d06c254257f528549e17306bf251d587d2c15a22ecea3d0669
commentFileId-ad07d6efa0da7dc8c81d7c3672e194bb5e477a93762d90120e483d9dcfe31720
commentFileId-ccec509ed44ce509f6f9a2f069d19faec4f6292bcf2d779b989430d06d10fb7b
Table
| Pin | Name | Copper X | Copper Y | UID |
|---|---|---|---|---|
| 1 | DAT2 | -9.785 | 8.710 | fe000900-08cc-4c41-9978-603124f7743b |
| 2 | DAT3 | -7.835 | 8.710 | 73f899e6-eb05-4e29-b4f1-a88d8bf378a8 |
| 3 | CMD | -5.885 | 8.710 | 32512523-be74-47b6-9ff9-6f6f23ca25d4 |
| 4 | CD | -3.935 | 8.710 | e69b79eb-7bd2-485c-b929-27e9e0e715ea |
| 5 | VSS1 | -1.985 | 8.710 | 85abb491-7e99-4295-a6e5-afebd9be17a2 |
| 6 | VDD | -0.035 | 8.710 | 28c6821e-d261-46a1-9a1e-c69be6b64cde |
| 7 | CLK | 1.915 | 8.710 | bb83ed02-c1ab-4b08-979e-959228fc20cf |
| 8 | VSS2 | 5.190 | 8.710 | 53df4385-ebec-47d7-bc97-2a29979dedc7 |
| 9 | DAT0 | 7.140 | 8.710 | 375590fb-bfdf-4836-93cf-0b5756df2085 |
| 10 | DAT1 | 9.090 | 8.710 | 97a1486f-bcef-4bda-a742-555d6d92ce1e |
| 11 | W/P | 11.040 | 8.710 | cc68941d-e6d8-48f8-b53d-12f785194e0c |
| 12 | GND | 13.065 | 4.755 | 2d3d7d64-0658-4b54-afbe-4e5519463515 |
| 13 | GND | 13.065 | -8.395 | 5b556825-c663-47dc-8c81-0843d8f48b66 |
| 14 | GND | -13.065 | -8.395 | 9f12bec8-dbc3-462f-a2a3-073ebbca2ae8 |
| 15 | GND | -13.065 | 4.755 | f6868748-fc55-4ed2-b57e-a6a657772f9b |
0d7cc683-b757-4ec1-a7f4-5e54b693053e retained. Current stored footprint source.(at) coordinates plus copper offsets; Flux's direct node rules use copper centers plus hole offsets. Do not substitute one coordinate convention for the other.Table
| Targeted item | Final status | Fresh evidence and exact blocker |
|---|---|---|
| Mechanical exclusions | Failed / blocked | Fresh zone/polygon tree inspection returns no matching nodes. Source-file OCR confirms separate legends for connector outline, body-height keepout, and no-component area, but does not associate each hatch with a fully dimensioned closed boundary. Missing resolved inputs: each region's complete X/Y vertices relative to mounting-hole/contact-row datum; hatch-to-region assignment; numeric vertical clearance and its board-surface reference for any height-limited region. Do not substitute overall body bounds for these distinct regions. |
| Visible symbol pin numbers | Failed / blocked | Fresh symbol image still shows fifteen separate contacts with names/types but no visible pin-number labels. Fresh pin table has numbers 1–15 exactly once, all Passive, groups and orders unchanged. Property lookup rejects Show Pin Numbers, Pin Number Visibility and Symbol Pin Number as unknown. Canonical property list and three differently phrased help searches expose no supported visibility control. This control may be unavailable; no arbitrary property, pin renaming or custom-symbol workaround was applied. |
| Unsupported continuous voltage rating | Completed, no removal needed | Fresh full project metadata contains no Operating Voltage, Voltage Rating or Voltage property. Fresh fifteen-pin table likewise contains no voltage-rating property. No continuous rating was assigned from the 500-VAC dielectric-test figure mentioned in the review brief. A dielectric withstand test must not be represented as a continuous operating rating. |
| Audit and blockers | Completed | This amendment records targeted readbacks and distinguishes the platform activation error from physical-manufacturing uncertainties. |
keepOut) is a distance outside object bounds and Zone Shape (zoneShape) supports custom SVG boundaries. The queried Component Height and Zone Type rules are unknown. A general spacing rule alone does not prove a supported height-limited mechanical-volume exclusion. Both exact source geometry and suitable part-source semantics must be established; no copper-routing prohibition was invented as a substitute for a component-only restriction.asset.payload still contains 1.52-mm contact lands and four records numbered 12. By contrast, the stored replacement source has unique pad numbers 1–15 and 1.60-mm contact lands, and active direct source-pad rules carry the corrected mapping/dimensions listed above. Resolved silk remains old rather than the revised source's ten clearance-adjusted segments. Upload success is not activation success. Stop automated activation retries; platform-side diagnosis is required.cornerRadius=0.575mm on 1.15 × 2.55-mm shell lands expresses the intended capsule, but actual rendered/exported rounding is not proven. The ±0.325-mm Flux hole offsets and KiCad hole-anchor/copper-offset conventions have not been independently verified through manufacturing output.Repair status — 2026-10-22
Source and evidence limits
Verified current project pin and pad readback
Manual-source rationale — unverified citation status
Footprint asset and unresolved activation
Verification and release blockers
Focused final review — independent-review follow-up
Mechanical source and supported-rule limits
Platform and manufacturing blockers retained without retry