I confirmed that all four shield pads are numbered 6, but only one renders—three are missing; simply assigning new numbers would leave them without matching terminals. I made no changes and filed an internal quality ticket for Flux team review.
May I add three matching shield terminals and give the four shield pads unique numbers, preserving their geometry, the five signal pins, and the 3D alignment?
I’ll add three shield terminals and map them to the missing pads, then verify that all four shield pads render without changing their geometry or the 3D alignment.
Thought for 11 mins 57 sec
14 days ago
Thought for 15 sec
Thought for 7 sec
Awaiting 1 task
"Repairing MICRO 4P DIP Shield Pad Mapping" completed.
The three terminals are added, and all four shield pads now render. I’m checking the final pin mappings and confirming that the signal pads, footprint geometry, and Model transform stayed unchanged.
Added EH2/7, EH3/8, and EH4/9 and updated the footprint mappings—all four shield pads now render, giving 9 electrical pads plus 2 locator holes. Verified that the five signal mappings, footprint geometry, and 3D model alignment remain unchanged.
Completed the approved three-terminal expansion and source-number repair. Live footprint has 9 electrical pads (5 contacts + 4 shell slots) and 2 locator holes. No shell terminal was connected to signal GND: the part schematic still has zero nets and zero wires. No duplicate internal quality report was filed.
Exact source change and live mappings
KiCad source Y is inverted in the Flux scene. The final existing source slot remains pin 6, preserving EH at lower right.
Table
Terminal
Source number before → after
Source X,Y (mm)
Live scene X,Y (mm)
Scene location
EH
6 → 6
+3.58,+1.72
+3.58,-1.72
Lower right
EH2
6 → 7
-3.58,-1.72
-3.58,+1.72
Upper left
EH3
6 → 8
-3.58,+1.72
-3.58,-1.72
Lower left
EH4
6 → 9
+3.58,-1.72
+3.58,+1.72
Upper right
New EH2/EH3/EH4 have Pin Type Passive and Bottom symbol orientation. Existing six terminal UIDs, properties, schematic positions and mappings were not edited. The parametric symbol now renders nine pins; adding bottom pins automatically redistributes bottom pin positions, so the symbol outline/pin drawing is not pixel-identical even though existing pin properties are preserved.
Geometry preservation
A byte-level comparison proved exactly three pad-number substitutions and every other source byte unchanged. The uploaded durable source was downloaded again and compared byte-identically with the verified replacement.
Shell pad size remains 1.00 × 1.70 mm, drill oval remains 0.5999987999999999 × 1.3000228 mm, with original layers unchanged.
Signal mappings remain 1=VCC, 2=D-, 3=D+, 4=ID, 5=GND. Live positions are X=-1.30,-0.65,0,+0.65,+1.30 mm respectively, all Y=+1.23 mm; size 0.40 × 1.40 mm.
Locator holes remain at live (±2.00,+0.40) mm, diameter 0.70 mm. Generated mount-node identifiers changed when the asset payload refreshed; geometry did not.
Outline, silk, source model reference and source model transform bytes are unchanged.
ROOT.Model remains position (0,-1.75,-0.04) mm, rotation (0,0,-180°), same model asset and unit scale.
Read-only live layout inspection confirmed all four shell pad nodes at the mapped positions with the original 1.00 × 1.70 mm size. Symbol pin-table readback confirmed all nine unique numbers, and the rendered symbol showed the added shell pins. Final schematic readback confirmed no changes to old terminals and zero nets/wires.
The generic layout-image reader does not correctly expose copper in this part-only project (no board layout). Therefore visual verification used a native current-project SVG export, rasterized without geometry reconstruction: all four plated oval slots, five signal pads and two locator holes are visibly present.
Schematic arrangement checks returned zero errors/warnings/notes and no drawing-quality items. PCB post-mutation DRC validators returned NOT CHECKED; this is not a blanket DRC-clean or manufacturing-ready claim. Existing source dimensions were preserved, not redesigned or certified against a datasheet.
Mutations and commits
#53b5eab2: Add EH2/EH3/EH4.
#7f55792b: Remove temporary Functional Group required by the add-tool schema; no extra component metadata remains.
#e2ac4f7b: Update existing footprint asset bffae3b1-0b6a-47bb-9c30-0d8bd15bde16 with three number substitutions.
#2eb2f14f: Arrange only new terminals alongside EH in the part schematic.
#59791332: Refresh the footprint Asset binding to the same asset name so its embedded payload uses updated numbers. Asset upload alone left the old embedded payload active; this refresh resolved the default pads at origin.
Scope status
Diagnose duplicate-number suppression: completed.
Add three passive shell terminals: completed.
Renumber existing source slots only: completed.
Live pad count/position and visual verification: completed.
Source geometry, existing terminal data and Model preservation: completed.
Full DRC certification: unavailable in this part-project check, not claimed.
Publishing a new library version or updating external board instances: unattempted; outside this assigned repair batch.